Cargando…
Multiplex Real-Time PCR Method for Simultaneous Identification and Toxigenic Type Characterization of Clostridium difficile From Stool Samples
BACKGROUND: The aim of this study was to develop and validate a multiplex real-time PCR assay for simultaneous identification and toxigenic type characterization of Clostridium difficile. METHODS: The multiplex real-time PCR assay targeted and simultaneously detected triose phosphate isomerase (tpi)...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society for Laboratory Medicine
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4390698/ https://www.ncbi.nlm.nih.gov/pubmed/25932438 http://dx.doi.org/10.3343/alm.2015.35.3.306 |
_version_ | 1782365715721879552 |
---|---|
author | Kilic, Abdullah Alam, Mohammad J. Tisdel, Naradah L. Shah, Dhara N. Yapar, Mehmet Lasco, Todd M. Garey, Kevin W. |
author_facet | Kilic, Abdullah Alam, Mohammad J. Tisdel, Naradah L. Shah, Dhara N. Yapar, Mehmet Lasco, Todd M. Garey, Kevin W. |
author_sort | Kilic, Abdullah |
collection | PubMed |
description | BACKGROUND: The aim of this study was to develop and validate a multiplex real-time PCR assay for simultaneous identification and toxigenic type characterization of Clostridium difficile. METHODS: The multiplex real-time PCR assay targeted and simultaneously detected triose phosphate isomerase (tpi) and binary toxin (cdtA) genes, and toxin A (tcdA) and B (tcdB) genes in the first and sec tubes, respectively. The results of multiplex real-time PCR were compared to those of the BD GeneOhm Cdiff assay, targeting the tcdB gene alone. The toxigenic culture was used as the reference, where toxin genes were detected by multiplex real-time PCR. RESULTS: A total of 351 stool samples from consecutive patients were included in the study. Fifty-five stool samples (15.6%) were determined to be positive for the presence of C. difficile by using multiplex real-time PCR. Of these, 48 (87.2%) were toxigenic (46 tcdA and tcdB-positive, two positive for only tcdB) and 11 (22.9%) were cdtA-positive. The sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of the multiplex real-time PCR compared with the toxigenic culture were 95.6%, 98.6%, 91.6%, and 99.3%, respectively. The analytical sensitivity of the multiplex real-time PCR assay was determined to be 103colonyforming unit (CFU)/g spiked stool sample and 0.0625 pg genomic DNA from culture. Analytical specificity determined by using 15 enteric and non-clostridial reference strains was 100%. CONCLUSIONS: The multiplex real-time PCR assay accurately detected C. difficile isolates from diarrheal stool samples and characterized its toxin genes in a single PCR run. |
format | Online Article Text |
id | pubmed-4390698 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society for Laboratory Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-43906982015-05-01 Multiplex Real-Time PCR Method for Simultaneous Identification and Toxigenic Type Characterization of Clostridium difficile From Stool Samples Kilic, Abdullah Alam, Mohammad J. Tisdel, Naradah L. Shah, Dhara N. Yapar, Mehmet Lasco, Todd M. Garey, Kevin W. Ann Lab Med Original Article BACKGROUND: The aim of this study was to develop and validate a multiplex real-time PCR assay for simultaneous identification and toxigenic type characterization of Clostridium difficile. METHODS: The multiplex real-time PCR assay targeted and simultaneously detected triose phosphate isomerase (tpi) and binary toxin (cdtA) genes, and toxin A (tcdA) and B (tcdB) genes in the first and sec tubes, respectively. The results of multiplex real-time PCR were compared to those of the BD GeneOhm Cdiff assay, targeting the tcdB gene alone. The toxigenic culture was used as the reference, where toxin genes were detected by multiplex real-time PCR. RESULTS: A total of 351 stool samples from consecutive patients were included in the study. Fifty-five stool samples (15.6%) were determined to be positive for the presence of C. difficile by using multiplex real-time PCR. Of these, 48 (87.2%) were toxigenic (46 tcdA and tcdB-positive, two positive for only tcdB) and 11 (22.9%) were cdtA-positive. The sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of the multiplex real-time PCR compared with the toxigenic culture were 95.6%, 98.6%, 91.6%, and 99.3%, respectively. The analytical sensitivity of the multiplex real-time PCR assay was determined to be 103colonyforming unit (CFU)/g spiked stool sample and 0.0625 pg genomic DNA from culture. Analytical specificity determined by using 15 enteric and non-clostridial reference strains was 100%. CONCLUSIONS: The multiplex real-time PCR assay accurately detected C. difficile isolates from diarrheal stool samples and characterized its toxin genes in a single PCR run. The Korean Society for Laboratory Medicine 2015-05 2015-04-01 /pmc/articles/PMC4390698/ /pubmed/25932438 http://dx.doi.org/10.3343/alm.2015.35.3.306 Text en © The Korean Society for Laboratory Medicine. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kilic, Abdullah Alam, Mohammad J. Tisdel, Naradah L. Shah, Dhara N. Yapar, Mehmet Lasco, Todd M. Garey, Kevin W. Multiplex Real-Time PCR Method for Simultaneous Identification and Toxigenic Type Characterization of Clostridium difficile From Stool Samples |
title | Multiplex Real-Time PCR Method for Simultaneous Identification and Toxigenic Type Characterization of Clostridium difficile From Stool Samples |
title_full | Multiplex Real-Time PCR Method for Simultaneous Identification and Toxigenic Type Characterization of Clostridium difficile From Stool Samples |
title_fullStr | Multiplex Real-Time PCR Method for Simultaneous Identification and Toxigenic Type Characterization of Clostridium difficile From Stool Samples |
title_full_unstemmed | Multiplex Real-Time PCR Method for Simultaneous Identification and Toxigenic Type Characterization of Clostridium difficile From Stool Samples |
title_short | Multiplex Real-Time PCR Method for Simultaneous Identification and Toxigenic Type Characterization of Clostridium difficile From Stool Samples |
title_sort | multiplex real-time pcr method for simultaneous identification and toxigenic type characterization of clostridium difficile from stool samples |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4390698/ https://www.ncbi.nlm.nih.gov/pubmed/25932438 http://dx.doi.org/10.3343/alm.2015.35.3.306 |
work_keys_str_mv | AT kilicabdullah multiplexrealtimepcrmethodforsimultaneousidentificationandtoxigenictypecharacterizationofclostridiumdifficilefromstoolsamples AT alammohammadj multiplexrealtimepcrmethodforsimultaneousidentificationandtoxigenictypecharacterizationofclostridiumdifficilefromstoolsamples AT tisdelnaradahl multiplexrealtimepcrmethodforsimultaneousidentificationandtoxigenictypecharacterizationofclostridiumdifficilefromstoolsamples AT shahdharan multiplexrealtimepcrmethodforsimultaneousidentificationandtoxigenictypecharacterizationofclostridiumdifficilefromstoolsamples AT yaparmehmet multiplexrealtimepcrmethodforsimultaneousidentificationandtoxigenictypecharacterizationofclostridiumdifficilefromstoolsamples AT lascotoddm multiplexrealtimepcrmethodforsimultaneousidentificationandtoxigenictypecharacterizationofclostridiumdifficilefromstoolsamples AT gareykevinw multiplexrealtimepcrmethodforsimultaneousidentificationandtoxigenictypecharacterizationofclostridiumdifficilefromstoolsamples |