A New Method for Calculating Femoral Anterior Cortex Point Location and Its Effect on Component Sizing and Placement
BACKGROUND: Variation in anterior femoral cortex morphology can cause improper component placement and alignment. When surgical inaccuracies occur, the mechanical properties of the distal femur may be altered, which could result in lower surgical success rates and an increased chance of postoperativ...