Cargando…
Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
[Purpose] The purpose of this study was to examine the intra-examiner and inter-examiner reliabilities of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer (HHD). [Subjects] Fifty-four healthy adults (35 males; average age, 23 years) participated in this study. [M...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Society of Physical Therapy Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4395755/ https://www.ncbi.nlm.nih.gov/pubmed/25931771 http://dx.doi.org/10.1589/jpts.27.967 |
_version_ | 1782366492220719104 |
---|---|
author | Suzuki, Terumi |
author_facet | Suzuki, Terumi |
author_sort | Suzuki, Terumi |
collection | PubMed |
description | [Purpose] The purpose of this study was to examine the intra-examiner and inter-examiner reliabilities of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer (HHD). [Subjects] Fifty-four healthy adults (35 males; average age, 23 years) participated in this study. [Methods] Knee extensor muscle strength of each leg was measured three times using the HHD. To examine the intra- and inter-examiner reliabilities, measurements were performed by two examiners, a physical therapist and a physical therapy student. [Results] The intra-examiner reliabilities, ICC (1, 1) and ICC (1, 3) ranged from 0.94–0.99. The inter-examiner reliabilities, ICC (2, 1) and ICC (3, 1) ranged from 0.90–0.92 for the right leg, and 0.88−0.90 for the left leg. Neither constant nor proportional errors were found by Bland-Altman analysis. [Conclusion] Intra-examiner and inter-examiner reliabilities were acceptable, indicating that muscle strength can be measured with the pull-type HHD without dependence on skill of measurement. Pain was not caused by measurements with the pull-type HHD. |
format | Online Article Text |
id | pubmed-4395755 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Society of Physical Therapy Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-43957552015-04-30 Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer Suzuki, Terumi J Phys Ther Sci Technical Note [Purpose] The purpose of this study was to examine the intra-examiner and inter-examiner reliabilities of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer (HHD). [Subjects] Fifty-four healthy adults (35 males; average age, 23 years) participated in this study. [Methods] Knee extensor muscle strength of each leg was measured three times using the HHD. To examine the intra- and inter-examiner reliabilities, measurements were performed by two examiners, a physical therapist and a physical therapy student. [Results] The intra-examiner reliabilities, ICC (1, 1) and ICC (1, 3) ranged from 0.94–0.99. The inter-examiner reliabilities, ICC (2, 1) and ICC (3, 1) ranged from 0.90–0.92 for the right leg, and 0.88−0.90 for the left leg. Neither constant nor proportional errors were found by Bland-Altman analysis. [Conclusion] Intra-examiner and inter-examiner reliabilities were acceptable, indicating that muscle strength can be measured with the pull-type HHD without dependence on skill of measurement. Pain was not caused by measurements with the pull-type HHD. The Society of Physical Therapy Science 2015-03-31 2015-03 /pmc/articles/PMC4395755/ /pubmed/25931771 http://dx.doi.org/10.1589/jpts.27.967 Text en 2015©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License. |
spellingShingle | Technical Note Suzuki, Terumi Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer |
title | Reliability of measurements of knee extensor muscle strength using a
pull-type hand-held dynamometer |
title_full | Reliability of measurements of knee extensor muscle strength using a
pull-type hand-held dynamometer |
title_fullStr | Reliability of measurements of knee extensor muscle strength using a
pull-type hand-held dynamometer |
title_full_unstemmed | Reliability of measurements of knee extensor muscle strength using a
pull-type hand-held dynamometer |
title_short | Reliability of measurements of knee extensor muscle strength using a
pull-type hand-held dynamometer |
title_sort | reliability of measurements of knee extensor muscle strength using a
pull-type hand-held dynamometer |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4395755/ https://www.ncbi.nlm.nih.gov/pubmed/25931771 http://dx.doi.org/10.1589/jpts.27.967 |
work_keys_str_mv | AT suzukiterumi reliabilityofmeasurementsofkneeextensormusclestrengthusingapulltypehandhelddynamometer |