Cargando…

Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer

[Purpose] The purpose of this study was to examine the intra-examiner and inter-examiner reliabilities of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer (HHD). [Subjects] Fifty-four healthy adults (35 males; average age, 23 years) participated in this study. [M...

Descripción completa

Detalles Bibliográficos
Autor principal: Suzuki, Terumi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4395755/
https://www.ncbi.nlm.nih.gov/pubmed/25931771
http://dx.doi.org/10.1589/jpts.27.967
_version_ 1782366492220719104
author Suzuki, Terumi
author_facet Suzuki, Terumi
author_sort Suzuki, Terumi
collection PubMed
description [Purpose] The purpose of this study was to examine the intra-examiner and inter-examiner reliabilities of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer (HHD). [Subjects] Fifty-four healthy adults (35 males; average age, 23 years) participated in this study. [Methods] Knee extensor muscle strength of each leg was measured three times using the HHD. To examine the intra- and inter-examiner reliabilities, measurements were performed by two examiners, a physical therapist and a physical therapy student. [Results] The intra-examiner reliabilities, ICC (1, 1) and ICC (1, 3) ranged from 0.94–0.99. The inter-examiner reliabilities, ICC (2, 1) and ICC (3, 1) ranged from 0.90–0.92 for the right leg, and 0.88−0.90 for the left leg. Neither constant nor proportional errors were found by Bland-Altman analysis. [Conclusion] Intra-examiner and inter-examiner reliabilities were acceptable, indicating that muscle strength can be measured with the pull-type HHD without dependence on skill of measurement. Pain was not caused by measurements with the pull-type HHD.
format Online
Article
Text
id pubmed-4395755
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-43957552015-04-30 Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer Suzuki, Terumi J Phys Ther Sci Technical Note [Purpose] The purpose of this study was to examine the intra-examiner and inter-examiner reliabilities of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer (HHD). [Subjects] Fifty-four healthy adults (35 males; average age, 23 years) participated in this study. [Methods] Knee extensor muscle strength of each leg was measured three times using the HHD. To examine the intra- and inter-examiner reliabilities, measurements were performed by two examiners, a physical therapist and a physical therapy student. [Results] The intra-examiner reliabilities, ICC (1, 1) and ICC (1, 3) ranged from 0.94–0.99. The inter-examiner reliabilities, ICC (2, 1) and ICC (3, 1) ranged from 0.90–0.92 for the right leg, and 0.88−0.90 for the left leg. Neither constant nor proportional errors were found by Bland-Altman analysis. [Conclusion] Intra-examiner and inter-examiner reliabilities were acceptable, indicating that muscle strength can be measured with the pull-type HHD without dependence on skill of measurement. Pain was not caused by measurements with the pull-type HHD. The Society of Physical Therapy Science 2015-03-31 2015-03 /pmc/articles/PMC4395755/ /pubmed/25931771 http://dx.doi.org/10.1589/jpts.27.967 Text en 2015©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
spellingShingle Technical Note
Suzuki, Terumi
Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
title Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
title_full Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
title_fullStr Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
title_full_unstemmed Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
title_short Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
title_sort reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4395755/
https://www.ncbi.nlm.nih.gov/pubmed/25931771
http://dx.doi.org/10.1589/jpts.27.967
work_keys_str_mv AT suzukiterumi reliabilityofmeasurementsofkneeextensormusclestrengthusingapulltypehandhelddynamometer