Cargando…
A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique
CAPD catheter malfunction is a common problem. Obstruction due to wrapping by appendices epiploicae of sigmoid colon has been rarely reported in literature. We report a case of CAPD catheter malfunction caused by catheter tip migration and obstruction by appendices epiploicae that was successfully m...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4396549/ https://www.ncbi.nlm.nih.gov/pubmed/25918653 http://dx.doi.org/10.1155/2015/684976 |
_version_ | 1782366598051397632 |
---|---|
author | Kumar, Santosh Singh, Shivanshu Sharma, Aditya Prakash Rathi, Manish |
author_facet | Kumar, Santosh Singh, Shivanshu Sharma, Aditya Prakash Rathi, Manish |
author_sort | Kumar, Santosh |
collection | PubMed |
description | CAPD catheter malfunction is a common problem. Obstruction due to wrapping by appendices epiploicae of sigmoid colon has been rarely reported in literature. We report a case of CAPD catheter malfunction caused by catheter tip migration and obstruction by appendices epiploicae that was successfully managed by laparoscopic hanging loop technique. This case report highlights the ease with which epiplopexy can be performed and catheter tip migration can be prevented by this innovative laparoscopic procedure. |
format | Online Article Text |
id | pubmed-4396549 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-43965492015-04-27 A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique Kumar, Santosh Singh, Shivanshu Sharma, Aditya Prakash Rathi, Manish Case Rep Nephrol Case Report CAPD catheter malfunction is a common problem. Obstruction due to wrapping by appendices epiploicae of sigmoid colon has been rarely reported in literature. We report a case of CAPD catheter malfunction caused by catheter tip migration and obstruction by appendices epiploicae that was successfully managed by laparoscopic hanging loop technique. This case report highlights the ease with which epiplopexy can be performed and catheter tip migration can be prevented by this innovative laparoscopic procedure. Hindawi Publishing Corporation 2015 2015-03-30 /pmc/articles/PMC4396549/ /pubmed/25918653 http://dx.doi.org/10.1155/2015/684976 Text en Copyright © 2015 Santosh Kumar et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Kumar, Santosh Singh, Shivanshu Sharma, Aditya Prakash Rathi, Manish A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique |
title | A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique |
title_full | A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique |
title_fullStr | A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique |
title_full_unstemmed | A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique |
title_short | A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique |
title_sort | novel technique for laparoscopic salvage of capd catheter malfunction and migration: the santosh-pgi hanging loop technique |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4396549/ https://www.ncbi.nlm.nih.gov/pubmed/25918653 http://dx.doi.org/10.1155/2015/684976 |
work_keys_str_mv | AT kumarsantosh anoveltechniqueforlaparoscopicsalvageofcapdcathetermalfunctionandmigrationthesantoshpgihanginglooptechnique AT singhshivanshu anoveltechniqueforlaparoscopicsalvageofcapdcathetermalfunctionandmigrationthesantoshpgihanginglooptechnique AT sharmaadityaprakash anoveltechniqueforlaparoscopicsalvageofcapdcathetermalfunctionandmigrationthesantoshpgihanginglooptechnique AT rathimanish anoveltechniqueforlaparoscopicsalvageofcapdcathetermalfunctionandmigrationthesantoshpgihanginglooptechnique AT kumarsantosh noveltechniqueforlaparoscopicsalvageofcapdcathetermalfunctionandmigrationthesantoshpgihanginglooptechnique AT singhshivanshu noveltechniqueforlaparoscopicsalvageofcapdcathetermalfunctionandmigrationthesantoshpgihanginglooptechnique AT sharmaadityaprakash noveltechniqueforlaparoscopicsalvageofcapdcathetermalfunctionandmigrationthesantoshpgihanginglooptechnique AT rathimanish noveltechniqueforlaparoscopicsalvageofcapdcathetermalfunctionandmigrationthesantoshpgihanginglooptechnique |