Cargando…

Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure

A rapid and cleanup-free ultrasound-assisted extraction method is proposed for the simultaneous extraction of oxytetracycline, tetracycline, chlortetracycline, and doxycycline in manure. The analytes were determined using high-performance liquid chromatography with ultraviolet detector. The influenc...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Lanqing, Sun, Mingxing, Zhou, Hui, Zhou, Yun, Chen, Ping, Min, Hong, Shen, Guoqing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4397494/
https://www.ncbi.nlm.nih.gov/pubmed/25922787
http://dx.doi.org/10.1155/2015/290903
_version_ 1782366712357715968
author Li, Lanqing
Sun, Mingxing
Zhou, Hui
Zhou, Yun
Chen, Ping
Min, Hong
Shen, Guoqing
author_facet Li, Lanqing
Sun, Mingxing
Zhou, Hui
Zhou, Yun
Chen, Ping
Min, Hong
Shen, Guoqing
author_sort Li, Lanqing
collection PubMed
description A rapid and cleanup-free ultrasound-assisted extraction method is proposed for the simultaneous extraction of oxytetracycline, tetracycline, chlortetracycline, and doxycycline in manure. The analytes were determined using high-performance liquid chromatography with ultraviolet detector. The influence of several variables on the efficiency of the extraction procedure was investigated by single-factor experiments. The temperature, pH, and amount of extraction solution were selected for optimization experiment using response surface methodology. The calibration curves showed good linearity (R (2) > 0.99) for all analytes in the range of 0.1–20 μg/mL. The four antibiotics were successfully extracted from manure with recoveries ranging from 81.89 to 92.42% and good reproducibility (RSD, <4.06%) under optimal conditions, which include 50 mL of McIlvaine buffer extraction solution (pH 7.15) mixed with 1 g of manure sample, extraction temperature of 40°C, extraction time of 10 min, and three extraction cycles. Method quantification limits of 1.75–2.32 mg/kg were obtained for the studied compounds. The proposed procedure demonstrated clear reductions in extraction time and elimination of cleanup steps. Finally, the applicability to tetracyclines antibiotics determination in real samples was evaluated through the successful determination of four target analytes in swine, cow manure, and mixture of animal manure with inorganic fertilizer.
format Online
Article
Text
id pubmed-4397494
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-43974942015-04-28 Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure Li, Lanqing Sun, Mingxing Zhou, Hui Zhou, Yun Chen, Ping Min, Hong Shen, Guoqing J Anal Methods Chem Research Article A rapid and cleanup-free ultrasound-assisted extraction method is proposed for the simultaneous extraction of oxytetracycline, tetracycline, chlortetracycline, and doxycycline in manure. The analytes were determined using high-performance liquid chromatography with ultraviolet detector. The influence of several variables on the efficiency of the extraction procedure was investigated by single-factor experiments. The temperature, pH, and amount of extraction solution were selected for optimization experiment using response surface methodology. The calibration curves showed good linearity (R (2) > 0.99) for all analytes in the range of 0.1–20 μg/mL. The four antibiotics were successfully extracted from manure with recoveries ranging from 81.89 to 92.42% and good reproducibility (RSD, <4.06%) under optimal conditions, which include 50 mL of McIlvaine buffer extraction solution (pH 7.15) mixed with 1 g of manure sample, extraction temperature of 40°C, extraction time of 10 min, and three extraction cycles. Method quantification limits of 1.75–2.32 mg/kg were obtained for the studied compounds. The proposed procedure demonstrated clear reductions in extraction time and elimination of cleanup steps. Finally, the applicability to tetracyclines antibiotics determination in real samples was evaluated through the successful determination of four target analytes in swine, cow manure, and mixture of animal manure with inorganic fertilizer. Hindawi Publishing Corporation 2015 2015-04-01 /pmc/articles/PMC4397494/ /pubmed/25922787 http://dx.doi.org/10.1155/2015/290903 Text en Copyright © 2015 Lanqing Li et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Li, Lanqing
Sun, Mingxing
Zhou, Hui
Zhou, Yun
Chen, Ping
Min, Hong
Shen, Guoqing
Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure
title Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure
title_full Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure
title_fullStr Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure
title_full_unstemmed Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure
title_short Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure
title_sort response surface optimization of a rapid ultrasound-assisted extraction method for simultaneous determination of tetracycline antibiotics in manure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4397494/
https://www.ncbi.nlm.nih.gov/pubmed/25922787
http://dx.doi.org/10.1155/2015/290903
work_keys_str_mv AT lilanqing responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure
AT sunmingxing responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure
AT zhouhui responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure
AT zhouyun responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure
AT chenping responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure
AT minhong responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure
AT shenguoqing responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure