Cargando…
Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure
A rapid and cleanup-free ultrasound-assisted extraction method is proposed for the simultaneous extraction of oxytetracycline, tetracycline, chlortetracycline, and doxycycline in manure. The analytes were determined using high-performance liquid chromatography with ultraviolet detector. The influenc...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4397494/ https://www.ncbi.nlm.nih.gov/pubmed/25922787 http://dx.doi.org/10.1155/2015/290903 |
_version_ | 1782366712357715968 |
---|---|
author | Li, Lanqing Sun, Mingxing Zhou, Hui Zhou, Yun Chen, Ping Min, Hong Shen, Guoqing |
author_facet | Li, Lanqing Sun, Mingxing Zhou, Hui Zhou, Yun Chen, Ping Min, Hong Shen, Guoqing |
author_sort | Li, Lanqing |
collection | PubMed |
description | A rapid and cleanup-free ultrasound-assisted extraction method is proposed for the simultaneous extraction of oxytetracycline, tetracycline, chlortetracycline, and doxycycline in manure. The analytes were determined using high-performance liquid chromatography with ultraviolet detector. The influence of several variables on the efficiency of the extraction procedure was investigated by single-factor experiments. The temperature, pH, and amount of extraction solution were selected for optimization experiment using response surface methodology. The calibration curves showed good linearity (R (2) > 0.99) for all analytes in the range of 0.1–20 μg/mL. The four antibiotics were successfully extracted from manure with recoveries ranging from 81.89 to 92.42% and good reproducibility (RSD, <4.06%) under optimal conditions, which include 50 mL of McIlvaine buffer extraction solution (pH 7.15) mixed with 1 g of manure sample, extraction temperature of 40°C, extraction time of 10 min, and three extraction cycles. Method quantification limits of 1.75–2.32 mg/kg were obtained for the studied compounds. The proposed procedure demonstrated clear reductions in extraction time and elimination of cleanup steps. Finally, the applicability to tetracyclines antibiotics determination in real samples was evaluated through the successful determination of four target analytes in swine, cow manure, and mixture of animal manure with inorganic fertilizer. |
format | Online Article Text |
id | pubmed-4397494 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-43974942015-04-28 Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure Li, Lanqing Sun, Mingxing Zhou, Hui Zhou, Yun Chen, Ping Min, Hong Shen, Guoqing J Anal Methods Chem Research Article A rapid and cleanup-free ultrasound-assisted extraction method is proposed for the simultaneous extraction of oxytetracycline, tetracycline, chlortetracycline, and doxycycline in manure. The analytes were determined using high-performance liquid chromatography with ultraviolet detector. The influence of several variables on the efficiency of the extraction procedure was investigated by single-factor experiments. The temperature, pH, and amount of extraction solution were selected for optimization experiment using response surface methodology. The calibration curves showed good linearity (R (2) > 0.99) for all analytes in the range of 0.1–20 μg/mL. The four antibiotics were successfully extracted from manure with recoveries ranging from 81.89 to 92.42% and good reproducibility (RSD, <4.06%) under optimal conditions, which include 50 mL of McIlvaine buffer extraction solution (pH 7.15) mixed with 1 g of manure sample, extraction temperature of 40°C, extraction time of 10 min, and three extraction cycles. Method quantification limits of 1.75–2.32 mg/kg were obtained for the studied compounds. The proposed procedure demonstrated clear reductions in extraction time and elimination of cleanup steps. Finally, the applicability to tetracyclines antibiotics determination in real samples was evaluated through the successful determination of four target analytes in swine, cow manure, and mixture of animal manure with inorganic fertilizer. Hindawi Publishing Corporation 2015 2015-04-01 /pmc/articles/PMC4397494/ /pubmed/25922787 http://dx.doi.org/10.1155/2015/290903 Text en Copyright © 2015 Lanqing Li et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Li, Lanqing Sun, Mingxing Zhou, Hui Zhou, Yun Chen, Ping Min, Hong Shen, Guoqing Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure |
title | Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure |
title_full | Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure |
title_fullStr | Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure |
title_full_unstemmed | Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure |
title_short | Response Surface Optimization of a Rapid Ultrasound-Assisted Extraction Method for Simultaneous Determination of Tetracycline Antibiotics in Manure |
title_sort | response surface optimization of a rapid ultrasound-assisted extraction method for simultaneous determination of tetracycline antibiotics in manure |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4397494/ https://www.ncbi.nlm.nih.gov/pubmed/25922787 http://dx.doi.org/10.1155/2015/290903 |
work_keys_str_mv | AT lilanqing responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure AT sunmingxing responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure AT zhouhui responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure AT zhouyun responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure AT chenping responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure AT minhong responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure AT shenguoqing responsesurfaceoptimizationofarapidultrasoundassistedextractionmethodforsimultaneousdeterminationoftetracyclineantibioticsinmanure |