Objective Assessment and Design Improvement of a Staring, Sparse Transducer Array by the Spatial Crosstalk Matrix for 3D Photoacoustic Tomography

Accurate reconstruction of 3D photoacoustic (PA) images requires detection of photoacoustic signals from many angles. Several groups have adopted staring ultrasound arrays, but assessment of array performance has been limited. We previously reported on a method to calibrate a 3D PA tomography (PAT)...

Descripción completa

Detalles Bibliográficos
Autores principales: Wong, Philip, Kosik, Ivan, Raess, Avery, Carson, Jeffrey J. L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4398465/
https://www.ncbi.nlm.nih.gov/pubmed/25875177
http://dx.doi.org/10.1371/journal.pone.0124759
_version_ 1782366828881772544
author Wong, Philip
Kosik, Ivan
Raess, Avery
Carson, Jeffrey J. L.
author_facet Wong, Philip
Kosik, Ivan
Raess, Avery
Carson, Jeffrey J. L.
author_sort Wong, Philip
collection PubMed
description Accurate reconstruction of 3D photoacoustic (PA) images requires detection of photoacoustic signals from many angles. Several groups have adopted staring ultrasound arrays, but assessment of array performance has been limited. We previously reported on a method to calibrate a 3D PA tomography (PAT) staring array system and analyze system performance using singular value decomposition (SVD). The developed SVD metric, however, was impractical for large system matrices, which are typical of 3D PAT problems. The present study consisted of two main objectives. The first objective aimed to introduce the crosstalk matrix concept to the field of PAT for system design. Figures-of-merit utilized in this study were root mean square error, peak signal-to-noise ratio, mean absolute error, and a three dimensional structural similarity index, which were derived between the normalized spatial crosstalk matrix and the identity matrix. The applicability of this approach for 3D PAT was validated by observing the response of the figures-of-merit in relation to well-understood PAT sampling characteristics (i.e. spatial and temporal sampling rate). The second objective aimed to utilize the figures-of-merit to characterize and improve the performance of a near-spherical staring array design. Transducer arrangement, array radius, and array angular coverage were the design parameters examined. We observed that the performance of a 129-element staring transducer array for 3D PAT could be improved by selection of optimal values of the design parameters. The results suggested that this formulation could be used to objectively characterize 3D PAT system performance and would enable the development of efficient strategies for system design optimization.
format Online
Article
Text
id pubmed-4398465
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43984652015-04-21 Objective Assessment and Design Improvement of a Staring, Sparse Transducer Array by the Spatial Crosstalk Matrix for 3D Photoacoustic Tomography Wong, Philip Kosik, Ivan Raess, Avery Carson, Jeffrey J. L. PLoS One Research Article Accurate reconstruction of 3D photoacoustic (PA) images requires detection of photoacoustic signals from many angles. Several groups have adopted staring ultrasound arrays, but assessment of array performance has been limited. We previously reported on a method to calibrate a 3D PA tomography (PAT) staring array system and analyze system performance using singular value decomposition (SVD). The developed SVD metric, however, was impractical for large system matrices, which are typical of 3D PAT problems. The present study consisted of two main objectives. The first objective aimed to introduce the crosstalk matrix concept to the field of PAT for system design. Figures-of-merit utilized in this study were root mean square error, peak signal-to-noise ratio, mean absolute error, and a three dimensional structural similarity index, which were derived between the normalized spatial crosstalk matrix and the identity matrix. The applicability of this approach for 3D PAT was validated by observing the response of the figures-of-merit in relation to well-understood PAT sampling characteristics (i.e. spatial and temporal sampling rate). The second objective aimed to utilize the figures-of-merit to characterize and improve the performance of a near-spherical staring array design. Transducer arrangement, array radius, and array angular coverage were the design parameters examined. We observed that the performance of a 129-element staring transducer array for 3D PAT could be improved by selection of optimal values of the design parameters. The results suggested that this formulation could be used to objectively characterize 3D PAT system performance and would enable the development of efficient strategies for system design optimization. Public Library of Science 2015-04-15 /pmc/articles/PMC4398465/ /pubmed/25875177 http://dx.doi.org/10.1371/journal.pone.0124759 Text en © 2015 Wong et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Wong, Philip
Kosik, Ivan
Raess, Avery
Carson, Jeffrey J. L.
Objective Assessment and Design Improvement of a Staring, Sparse Transducer Array by the Spatial Crosstalk Matrix for 3D Photoacoustic Tomography
title Objective Assessment and Design Improvement of a Staring, Sparse Transducer Array by the Spatial Crosstalk Matrix for 3D Photoacoustic Tomography
title_full Objective Assessment and Design Improvement of a Staring, Sparse Transducer Array by the Spatial Crosstalk Matrix for 3D Photoacoustic Tomography
title_fullStr Objective Assessment and Design Improvement of a Staring, Sparse Transducer Array by the Spatial Crosstalk Matrix for 3D Photoacoustic Tomography
title_full_unstemmed Objective Assessment and Design Improvement of a Staring, Sparse Transducer Array by the Spatial Crosstalk Matrix for 3D Photoacoustic Tomography
title_short Objective Assessment and Design Improvement of a Staring, Sparse Transducer Array by the Spatial Crosstalk Matrix for 3D Photoacoustic Tomography
title_sort objective assessment and design improvement of a staring, sparse transducer array by the spatial crosstalk matrix for 3d photoacoustic tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4398465/
https://www.ncbi.nlm.nih.gov/pubmed/25875177
http://dx.doi.org/10.1371/journal.pone.0124759
work_keys_str_mv AT wongphilip objectiveassessmentanddesignimprovementofastaringsparsetransducerarraybythespatialcrosstalkmatrixfor3dphotoacoustictomography
AT kosikivan objectiveassessmentanddesignimprovementofastaringsparsetransducerarraybythespatialcrosstalkmatrixfor3dphotoacoustictomography
AT raessavery objectiveassessmentanddesignimprovementofastaringsparsetransducerarraybythespatialcrosstalkmatrixfor3dphotoacoustictomography
AT carsonjeffreyjl objectiveassessmentanddesignimprovementofastaringsparsetransducerarraybythespatialcrosstalkmatrixfor3dphotoacoustictomography