Cargando…

Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold

BACKGROUND: Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup ima...

Descripción completa

Detalles Bibliográficos
Autores principales: Laaksomaa, Marko, Kapanen, Mika, Haltamo, Mikko, Skyttä, Tanja, Peltola, Seppo, Hyödynmaa, Simo, Kellokumpu-Lehtinen, Pirkko-Liisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4399145/
https://www.ncbi.nlm.nih.gov/pubmed/25885270
http://dx.doi.org/10.1186/s13014-015-0383-y
_version_ 1782366897055989760
author Laaksomaa, Marko
Kapanen, Mika
Haltamo, Mikko
Skyttä, Tanja
Peltola, Seppo
Hyödynmaa, Simo
Kellokumpu-Lehtinen, Pirkko-Liisa
author_facet Laaksomaa, Marko
Kapanen, Mika
Haltamo, Mikko
Skyttä, Tanja
Peltola, Seppo
Hyödynmaa, Simo
Kellokumpu-Lehtinen, Pirkko-Liisa
author_sort Laaksomaa, Marko
collection PubMed
description BACKGROUND: Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. METHODS: 1067 sets of images with an orthogonal setup and tangential field from 67 patients were retrospectively analysed. Residual position errors were determined in the tangential treatment field images for different matches of the setup images. Variation of patient posture and BHL were analysed for position errors of the vertebrae, clavicula, ribs and sternum in the setup and tangential field images. The BHL was controlled with a Varian RPM® system. Setup margins were calculated using the van Herk’s formula. Patients who underwent lymph node irradiation were also investigated. RESULTS: For the breast alone, the midway compromise of the ribs and sternum was the best general choice for matching of the setup images. The required margins were 6.5 mm and 5.3 mm in superior-inferior (SI) and lateral/anterior-posterior (LAT/AP) directions, respectively. With the individually optimised image matching position also including the vertebrae, slightly smaller margins of 6.0 mm and 4.8 mm were achieved, respectively. With the individually optimised match, margins of 7.5 mm and 10.8 mm should be used in LAT and SI directions, respectively, for the lymph node regions. These margins were considered too large. The reproducibility of the BHL was within 5 mm in the AP direction for 75% of patients. CONCLUSIONS: The smallest setup margins were obtained when the matching position of the setup images was individually optimised for each patient. Optimal match for the breast alone is not optimal for the lymph node region, and, therefore, a threshold of 5 mm was introduced for residual position errors of the sternum, upper vertebrae, clavicula and chest wall to retain minimal setup margins of 5 mm. Because random interfraction variation in patient posture was large, we recommend daily online image guidance. The BHL should be verified with image guidance.
format Online
Article
Text
id pubmed-4399145
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-43991452015-04-17 Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold Laaksomaa, Marko Kapanen, Mika Haltamo, Mikko Skyttä, Tanja Peltola, Seppo Hyödynmaa, Simo Kellokumpu-Lehtinen, Pirkko-Liisa Radiat Oncol Research BACKGROUND: Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. METHODS: 1067 sets of images with an orthogonal setup and tangential field from 67 patients were retrospectively analysed. Residual position errors were determined in the tangential treatment field images for different matches of the setup images. Variation of patient posture and BHL were analysed for position errors of the vertebrae, clavicula, ribs and sternum in the setup and tangential field images. The BHL was controlled with a Varian RPM® system. Setup margins were calculated using the van Herk’s formula. Patients who underwent lymph node irradiation were also investigated. RESULTS: For the breast alone, the midway compromise of the ribs and sternum was the best general choice for matching of the setup images. The required margins were 6.5 mm and 5.3 mm in superior-inferior (SI) and lateral/anterior-posterior (LAT/AP) directions, respectively. With the individually optimised image matching position also including the vertebrae, slightly smaller margins of 6.0 mm and 4.8 mm were achieved, respectively. With the individually optimised match, margins of 7.5 mm and 10.8 mm should be used in LAT and SI directions, respectively, for the lymph node regions. These margins were considered too large. The reproducibility of the BHL was within 5 mm in the AP direction for 75% of patients. CONCLUSIONS: The smallest setup margins were obtained when the matching position of the setup images was individually optimised for each patient. Optimal match for the breast alone is not optimal for the lymph node region, and, therefore, a threshold of 5 mm was introduced for residual position errors of the sternum, upper vertebrae, clavicula and chest wall to retain minimal setup margins of 5 mm. Because random interfraction variation in patient posture was large, we recommend daily online image guidance. The BHL should be verified with image guidance. BioMed Central 2015-04-03 /pmc/articles/PMC4399145/ /pubmed/25885270 http://dx.doi.org/10.1186/s13014-015-0383-y Text en © Laaksomaa et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Laaksomaa, Marko
Kapanen, Mika
Haltamo, Mikko
Skyttä, Tanja
Peltola, Seppo
Hyödynmaa, Simo
Kellokumpu-Lehtinen, Pirkko-Liisa
Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
title Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
title_full Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
title_fullStr Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
title_full_unstemmed Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
title_short Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
title_sort determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4399145/
https://www.ncbi.nlm.nih.gov/pubmed/25885270
http://dx.doi.org/10.1186/s13014-015-0383-y
work_keys_str_mv AT laaksomaamarko determinationoftheoptimalmatchingpositionforsetupimagesandminimalsetupmarginsinadjuvantradiotherapyofbreastandlymphnodestreatedinvoluntarydeepinhalationbreathhold
AT kapanenmika determinationoftheoptimalmatchingpositionforsetupimagesandminimalsetupmarginsinadjuvantradiotherapyofbreastandlymphnodestreatedinvoluntarydeepinhalationbreathhold
AT haltamomikko determinationoftheoptimalmatchingpositionforsetupimagesandminimalsetupmarginsinadjuvantradiotherapyofbreastandlymphnodestreatedinvoluntarydeepinhalationbreathhold
AT skyttatanja determinationoftheoptimalmatchingpositionforsetupimagesandminimalsetupmarginsinadjuvantradiotherapyofbreastandlymphnodestreatedinvoluntarydeepinhalationbreathhold
AT peltolaseppo determinationoftheoptimalmatchingpositionforsetupimagesandminimalsetupmarginsinadjuvantradiotherapyofbreastandlymphnodestreatedinvoluntarydeepinhalationbreathhold
AT hyodynmaasimo determinationoftheoptimalmatchingpositionforsetupimagesandminimalsetupmarginsinadjuvantradiotherapyofbreastandlymphnodestreatedinvoluntarydeepinhalationbreathhold
AT kellokumpulehtinenpirkkoliisa determinationoftheoptimalmatchingpositionforsetupimagesandminimalsetupmarginsinadjuvantradiotherapyofbreastandlymphnodestreatedinvoluntarydeepinhalationbreathhold