Cargando…
Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
This study adapted human videofluoroscopic swallowing study (VFSS) methods for use with murine disease models for the purpose of facilitating translational dysphagia research. Successful outcomes are dependent upon three critical components: test chambers that permit self-feeding while standing unre...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MyJove Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4401177/ https://www.ncbi.nlm.nih.gov/pubmed/25866882 http://dx.doi.org/10.3791/52319 |
_version_ | 1782367107373072384 |
---|---|
author | Lever, Teresa E. Braun, Sabrina M. Brooks, Ryan T. Harris, Rebecca A. Littrell, Loren L. Neff, Ryan M. Hinkel, Cameron J. Allen, Mitchell J. Ulsas, Mollie A. |
author_facet | Lever, Teresa E. Braun, Sabrina M. Brooks, Ryan T. Harris, Rebecca A. Littrell, Loren L. Neff, Ryan M. Hinkel, Cameron J. Allen, Mitchell J. Ulsas, Mollie A. |
author_sort | Lever, Teresa E. |
collection | PubMed |
description | This study adapted human videofluoroscopic swallowing study (VFSS) methods for use with murine disease models for the purpose of facilitating translational dysphagia research. Successful outcomes are dependent upon three critical components: test chambers that permit self-feeding while standing unrestrained in a confined space, recipes that mask the aversive taste/odor of commercially-available oral contrast agents, and a step-by-step test protocol that permits quantification of swallow physiology. Elimination of one or more of these components will have a detrimental impact on the study results. Moreover, the energy level capability of the fluoroscopy system will determine which swallow parameters can be investigated. Most research centers have high energy fluoroscopes designed for use with people and larger animals, which results in exceptionally poor image quality when testing mice and other small rodents. Despite this limitation, we have identified seven VFSS parameters that are consistently quantifiable in mice when using a high energy fluoroscope in combination with the new murine VFSS protocol. We recently obtained a low energy fluoroscopy system with exceptionally high imaging resolution and magnification capabilities that was designed for use with mice and other small rodents. Preliminary work using this new system, in combination with the new murine VFSS protocol, has identified 13 swallow parameters that are consistently quantifiable in mice, which is nearly double the number obtained using conventional (i.e., high energy) fluoroscopes. Identification of additional swallow parameters is expected as we optimize the capabilities of this new system. Results thus far demonstrate the utility of using a low energy fluoroscopy system to detect and quantify subtle changes in swallow physiology that may otherwise be overlooked when using high energy fluoroscopes to investigate murine disease models. |
format | Online Article Text |
id | pubmed-4401177 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | MyJove Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-44011772015-04-24 Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models Lever, Teresa E. Braun, Sabrina M. Brooks, Ryan T. Harris, Rebecca A. Littrell, Loren L. Neff, Ryan M. Hinkel, Cameron J. Allen, Mitchell J. Ulsas, Mollie A. J Vis Exp Medicine This study adapted human videofluoroscopic swallowing study (VFSS) methods for use with murine disease models for the purpose of facilitating translational dysphagia research. Successful outcomes are dependent upon three critical components: test chambers that permit self-feeding while standing unrestrained in a confined space, recipes that mask the aversive taste/odor of commercially-available oral contrast agents, and a step-by-step test protocol that permits quantification of swallow physiology. Elimination of one or more of these components will have a detrimental impact on the study results. Moreover, the energy level capability of the fluoroscopy system will determine which swallow parameters can be investigated. Most research centers have high energy fluoroscopes designed for use with people and larger animals, which results in exceptionally poor image quality when testing mice and other small rodents. Despite this limitation, we have identified seven VFSS parameters that are consistently quantifiable in mice when using a high energy fluoroscope in combination with the new murine VFSS protocol. We recently obtained a low energy fluoroscopy system with exceptionally high imaging resolution and magnification capabilities that was designed for use with mice and other small rodents. Preliminary work using this new system, in combination with the new murine VFSS protocol, has identified 13 swallow parameters that are consistently quantifiable in mice, which is nearly double the number obtained using conventional (i.e., high energy) fluoroscopes. Identification of additional swallow parameters is expected as we optimize the capabilities of this new system. Results thus far demonstrate the utility of using a low energy fluoroscopy system to detect and quantify subtle changes in swallow physiology that may otherwise be overlooked when using high energy fluoroscopes to investigate murine disease models. MyJove Corporation 2015-03-01 /pmc/articles/PMC4401177/ /pubmed/25866882 http://dx.doi.org/10.3791/52319 Text en Copyright © 2015, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/ |
spellingShingle | Medicine Lever, Teresa E. Braun, Sabrina M. Brooks, Ryan T. Harris, Rebecca A. Littrell, Loren L. Neff, Ryan M. Hinkel, Cameron J. Allen, Mitchell J. Ulsas, Mollie A. Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models |
title | Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models |
title_full | Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models |
title_fullStr | Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models |
title_full_unstemmed | Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models |
title_short | Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models |
title_sort | adapting human videofluoroscopic swallow study methods to detect and characterize dysphagia in murine disease models |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4401177/ https://www.ncbi.nlm.nih.gov/pubmed/25866882 http://dx.doi.org/10.3791/52319 |
work_keys_str_mv | AT leverteresae adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels AT braunsabrinam adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels AT brooksryant adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels AT harrisrebeccaa adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels AT littrelllorenl adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels AT neffryanm adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels AT hinkelcameronj adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels AT allenmitchellj adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels AT ulsasmolliea adaptinghumanvideofluoroscopicswallowstudymethodstodetectandcharacterizedysphagiainmurinediseasemodels |