Evaluation of the Nova StatSensor(®) Xpress(TM) Creatinine Point-Of-Care Handheld Analyzer
Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-li...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4401790/ https://www.ncbi.nlm.nih.gov/pubmed/25886375 http://dx.doi.org/10.1371/journal.pone.0122433 |
_version_ | 1782367196884762624 |
---|---|
author | Kosack, Cara Simone de Kieviet, Wim Bayrak, Kubra Milovic, Anastacija Page, Anne Laure |
author_facet | Kosack, Cara Simone de Kieviet, Wim Bayrak, Kubra Milovic, Anastacija Page, Anne Laure |
author_sort | Kosack, Cara Simone |
collection | PubMed |
description | Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. |
format | Online Article Text |
id | pubmed-4401790 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-44017902015-04-21 Evaluation of the Nova StatSensor(®) Xpress(TM) Creatinine Point-Of-Care Handheld Analyzer Kosack, Cara Simone de Kieviet, Wim Bayrak, Kubra Milovic, Anastacija Page, Anne Laure PLoS One Research Article Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. Public Library of Science 2015-04-17 /pmc/articles/PMC4401790/ /pubmed/25886375 http://dx.doi.org/10.1371/journal.pone.0122433 Text en © 2015 Kosack et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Kosack, Cara Simone de Kieviet, Wim Bayrak, Kubra Milovic, Anastacija Page, Anne Laure Evaluation of the Nova StatSensor(®) Xpress(TM) Creatinine Point-Of-Care Handheld Analyzer |
title | Evaluation of the Nova StatSensor(®) Xpress(TM) Creatinine Point-Of-Care Handheld Analyzer |
title_full | Evaluation of the Nova StatSensor(®) Xpress(TM) Creatinine Point-Of-Care Handheld Analyzer |
title_fullStr | Evaluation of the Nova StatSensor(®) Xpress(TM) Creatinine Point-Of-Care Handheld Analyzer |
title_full_unstemmed | Evaluation of the Nova StatSensor(®) Xpress(TM) Creatinine Point-Of-Care Handheld Analyzer |
title_short | Evaluation of the Nova StatSensor(®) Xpress(TM) Creatinine Point-Of-Care Handheld Analyzer |
title_sort | evaluation of the nova statsensor(®) xpress(tm) creatinine point-of-care handheld analyzer |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4401790/ https://www.ncbi.nlm.nih.gov/pubmed/25886375 http://dx.doi.org/10.1371/journal.pone.0122433 |
work_keys_str_mv | AT kosackcarasimone evaluationofthenovastatsensorxpresstmcreatininepointofcarehandheldanalyzer AT dekievietwim evaluationofthenovastatsensorxpresstmcreatininepointofcarehandheldanalyzer AT bayrakkubra evaluationofthenovastatsensorxpresstmcreatininepointofcarehandheldanalyzer AT milovicanastacija evaluationofthenovastatsensorxpresstmcreatininepointofcarehandheldanalyzer AT pageannelaure evaluationofthenovastatsensorxpresstmcreatininepointofcarehandheldanalyzer |