Introduction: Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. Objectives: In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Materials and methods: T...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Universa Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4402446/ https://www.ncbi.nlm.nih.gov/pubmed/25897367 |
_version_ | 1782367253599092736 |
---|---|
author | Khazendar, S. Sayasneh, A. Al-Assam, H. Du, H. Kaijser, J. Ferrara, L. Timmerman, D. Jassim, S. Bourne, T. |
author_facet | Khazendar, S. Sayasneh, A. Al-Assam, H. Du, H. Kaijser, J. Ferrara, L. Timmerman, D. Jassim, S. Bourne, T. |
author_sort | Khazendar, S. |
collection | PubMed |
description | Introduction: Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. Objectives: In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Materials and methods: Transvaginal 2D B mode static ultrasound images of 187 ovarian masses with known histological diagnosis were included. Images were first pre-processed and enhanced, and Local Binary Pattern Histograms were then extracted from 2 × 2 blocks of each image. A Support Vector Machine (SVM) was trained using stratified cross validation with randomised sampling. The process was repeated 15 times and in each round 100 images were randomly selected. Results: The SVM classified the original non-treated static images as benign or malignant masses with an average accuracy of 0.62 (95% CI: 0.59-0.65). This performance significantly improved to an average accuracy of 0.77 (95% CI: 0.75-0.79) when images were pre-processed, enhanced and treated with a Local Binary Pattern operator (mean difference 0.15: 95% 0.11-0.19, p < 0.0001, two-tailed t test). Conclusion: We have shown that an SVM can classify static 2D B mode ultrasound images of ovarian masses into benign and malignant categories. The accuracy improves if texture related LBP features extracted from the images are considered. |
format | Online Article Text |
id | pubmed-4402446 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Universa Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-44024462015-04-20 Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator Khazendar, S. Sayasneh, A. Al-Assam, H. Du, H. Kaijser, J. Ferrara, L. Timmerman, D. Jassim, S. Bourne, T. Facts Views Vis Obgyn Original Paper Introduction: Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. Objectives: In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Materials and methods: Transvaginal 2D B mode static ultrasound images of 187 ovarian masses with known histological diagnosis were included. Images were first pre-processed and enhanced, and Local Binary Pattern Histograms were then extracted from 2 × 2 blocks of each image. A Support Vector Machine (SVM) was trained using stratified cross validation with randomised sampling. The process was repeated 15 times and in each round 100 images were randomly selected. Results: The SVM classified the original non-treated static images as benign or malignant masses with an average accuracy of 0.62 (95% CI: 0.59-0.65). This performance significantly improved to an average accuracy of 0.77 (95% CI: 0.75-0.79) when images were pre-processed, enhanced and treated with a Local Binary Pattern operator (mean difference 0.15: 95% 0.11-0.19, p < 0.0001, two-tailed t test). Conclusion: We have shown that an SVM can classify static 2D B mode ultrasound images of ovarian masses into benign and malignant categories. The accuracy improves if texture related LBP features extracted from the images are considered. Universa Press 2015 /pmc/articles/PMC4402446/ /pubmed/25897367 Text en Copyright: © 2015 Facts, Views & Vision http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Khazendar, S. Sayasneh, A. Al-Assam, H. Du, H. Kaijser, J. Ferrara, L. Timmerman, D. Jassim, S. Bourne, T. Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator |
title | Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator |
title_full | Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator |
title_fullStr | Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator |
title_full_unstemmed | Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator |
title_short | Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator |
title_sort | automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4402446/ https://www.ncbi.nlm.nih.gov/pubmed/25897367 |
work_keys_str_mv | AT khazendars automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator AT sayasneha automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator AT alassamh automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator AT duh automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator AT kaijserj automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator AT ferraral automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator AT timmermand automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator AT jassims automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator AT bournet automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator |