Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator

Introduction: Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. Objectives: In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Materials and methods: T...

Descripción completa

Detalles Bibliográficos
Autores principales: Khazendar, S., Sayasneh, A., Al-Assam, H., Du, H., Kaijser, J., Ferrara, L., Timmerman, D., Jassim, S., Bourne, T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Universa Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4402446/
https://www.ncbi.nlm.nih.gov/pubmed/25897367
_version_ 1782367253599092736
author Khazendar, S.
Sayasneh, A.
Al-Assam, H.
Du, H.
Kaijser, J.
Ferrara, L.
Timmerman, D.
Jassim, S.
Bourne, T.
author_facet Khazendar, S.
Sayasneh, A.
Al-Assam, H.
Du, H.
Kaijser, J.
Ferrara, L.
Timmerman, D.
Jassim, S.
Bourne, T.
author_sort Khazendar, S.
collection PubMed
description Introduction: Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. Objectives: In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Materials and methods: Transvaginal 2D B mode static ultrasound images of 187 ovarian masses with known histological diagnosis were included. Images were first pre-processed and enhanced, and Local Binary Pattern Histograms were then extracted from 2 × 2 blocks of each image. A Support Vector Machine (SVM) was trained using stratified cross validation with randomised sampling. The process was repeated 15 times and in each round 100 images were randomly selected. Results: The SVM classified the original non-treated static images as benign or malignant masses with an average accuracy of 0.62 (95% CI: 0.59-0.65). This performance significantly improved to an average accuracy of 0.77 (95% CI: 0.75-0.79) when images were pre-processed, enhanced and treated with a Local Binary Pattern operator (mean difference 0.15: 95% 0.11-0.19, p < 0.0001, two-tailed t test). Conclusion: We have shown that an SVM can classify static 2D B mode ultrasound images of ovarian masses into benign and malignant categories. The accuracy improves if texture related LBP features extracted from the images are considered.
format Online
Article
Text
id pubmed-4402446
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Universa Press
record_format MEDLINE/PubMed
spelling pubmed-44024462015-04-20 Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator Khazendar, S. Sayasneh, A. Al-Assam, H. Du, H. Kaijser, J. Ferrara, L. Timmerman, D. Jassim, S. Bourne, T. Facts Views Vis Obgyn Original Paper Introduction: Preoperative characterisation of ovarian masses into benign or malignant is of paramount importance to optimise patient management. Objectives: In this study, we developed and validated a computerised model to characterise ovarian masses as benign or malignant. Materials and methods: Transvaginal 2D B mode static ultrasound images of 187 ovarian masses with known histological diagnosis were included. Images were first pre-processed and enhanced, and Local Binary Pattern Histograms were then extracted from 2 × 2 blocks of each image. A Support Vector Machine (SVM) was trained using stratified cross validation with randomised sampling. The process was repeated 15 times and in each round 100 images were randomly selected. Results: The SVM classified the original non-treated static images as benign or malignant masses with an average accuracy of 0.62 (95% CI: 0.59-0.65). This performance significantly improved to an average accuracy of 0.77 (95% CI: 0.75-0.79) when images were pre-processed, enhanced and treated with a Local Binary Pattern operator (mean difference 0.15: 95% 0.11-0.19, p < 0.0001, two-tailed t test). Conclusion: We have shown that an SVM can classify static 2D B mode ultrasound images of ovarian masses into benign and malignant categories. The accuracy improves if texture related LBP features extracted from the images are considered. Universa Press 2015 /pmc/articles/PMC4402446/ /pubmed/25897367 Text en Copyright: © 2015 Facts, Views & Vision http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Khazendar, S.
Sayasneh, A.
Al-Assam, H.
Du, H.
Kaijser, J.
Ferrara, L.
Timmerman, D.
Jassim, S.
Bourne, T.
Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator
title Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator
title_full Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator
title_fullStr Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator
title_full_unstemmed Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator
title_short Automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator
title_sort automated characterisation of ultrasound images of ovarian tumours: the diagnostic accuracy of a support vector machine and image processing with a local binary pattern operator
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4402446/
https://www.ncbi.nlm.nih.gov/pubmed/25897367
work_keys_str_mv AT khazendars automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator
AT sayasneha automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator
AT alassamh automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator
AT duh automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator
AT kaijserj automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator
AT ferraral automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator
AT timmermand automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator
AT jassims automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator
AT bournet automatedcharacterisationofultrasoundimagesofovariantumoursthediagnosticaccuracyofasupportvectormachineandimageprocessingwithalocalbinarypatternoperator