Normal values for cardiovascular magnetic resonance in adults and children

Morphological and functional parameters such as chamber size and function, aortic diameters and distensibility, flow and T1 and T2* relaxation time can be assessed and quantified by cardiovascular magnetic resonance (CMR). Knowledge of normal values for quantitative CMR is crucial to interpretation...

Descripción completa

Detalles Bibliográficos
Autores principales: Kawel-Boehm, Nadine, Maceira, Alicia, Valsangiacomo-Buechel, Emanuela R, Vogel-Claussen, Jens, Turkbey, Evrim B, Williams, Rupert, Plein, Sven, Tee, Michael, Eng, John, Bluemke, David A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4403942/
https://www.ncbi.nlm.nih.gov/pubmed/25928314
http://dx.doi.org/10.1186/s12968-015-0111-7
Descripción
Sumario:Morphological and functional parameters such as chamber size and function, aortic diameters and distensibility, flow and T1 and T2* relaxation time can be assessed and quantified by cardiovascular magnetic resonance (CMR). Knowledge of normal values for quantitative CMR is crucial to interpretation of results and to distinguish normal from disease. In this review, we present normal reference values for morphological and functional CMR parameters of the cardiovascular system based on the peer-reviewed literature and current CMR techniques and sequences. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12968-015-0111-7) contains supplementary material, which is available to authorized users.