Mobile- vs. fixed-bearing total knee replacement: A randomized radiostereometric and bone mineral density study

BACKGROUND AND PURPOSE: It is unclear whether mobile-bearing (MB) total knee arthroplasties reduce the risk of tibial component loosening compared to fixed-bearing (FB) designs. This randomized study investigated implant migration, periprosthetic bone mineral density (BMD), and patient-reported outc...

Descripción completa

Detalles Bibliográficos
Autores principales: Tjørnild, Michael, Søballe, Kjeld, Hansen, Per Møller, Holm, Carsten, Stilling, Maiken
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Informa Healthcare 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4404772/
https://www.ncbi.nlm.nih.gov/pubmed/25280132
http://dx.doi.org/10.3109/17453674.2014.968476