Cargando…

Comparison of Peak Cardiopulmonary Performance Parameters on a Robotics-Assisted Tilt Table, a Cycle and a Treadmill

Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may...

Descripción completa

Detalles Bibliográficos
Autores principales: Saengsuwan, Jittima, Nef, Tobias, Laubacher, Marco, Hunt, Kenneth J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4405815/
https://www.ncbi.nlm.nih.gov/pubmed/25860019
http://dx.doi.org/10.1371/journal.pone.0122767
_version_ 1782367665786978304
author Saengsuwan, Jittima
Nef, Tobias
Laubacher, Marco
Hunt, Kenneth J.
author_facet Saengsuwan, Jittima
Nef, Tobias
Laubacher, Marco
Hunt, Kenneth J.
author_sort Saengsuwan, Jittima
collection PubMed
description Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO(2peak)) and peak heart rate (HR(peak)) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO(2peak) and HR(peak) were assessed. Absolute VO(2peak) from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HR(peak) from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO(2peak) and HR(peak) from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO(2peak) and HR(peak) for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.
format Online
Article
Text
id pubmed-4405815
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44058152015-05-07 Comparison of Peak Cardiopulmonary Performance Parameters on a Robotics-Assisted Tilt Table, a Cycle and a Treadmill Saengsuwan, Jittima Nef, Tobias Laubacher, Marco Hunt, Kenneth J. PLoS One Research Article Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO(2peak)) and peak heart rate (HR(peak)) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO(2peak) and HR(peak) were assessed. Absolute VO(2peak) from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HR(peak) from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO(2peak) and HR(peak) from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO(2peak) and HR(peak) for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities. Public Library of Science 2015-04-10 /pmc/articles/PMC4405815/ /pubmed/25860019 http://dx.doi.org/10.1371/journal.pone.0122767 Text en © 2015 Saengsuwan et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Saengsuwan, Jittima
Nef, Tobias
Laubacher, Marco
Hunt, Kenneth J.
Comparison of Peak Cardiopulmonary Performance Parameters on a Robotics-Assisted Tilt Table, a Cycle and a Treadmill
title Comparison of Peak Cardiopulmonary Performance Parameters on a Robotics-Assisted Tilt Table, a Cycle and a Treadmill
title_full Comparison of Peak Cardiopulmonary Performance Parameters on a Robotics-Assisted Tilt Table, a Cycle and a Treadmill
title_fullStr Comparison of Peak Cardiopulmonary Performance Parameters on a Robotics-Assisted Tilt Table, a Cycle and a Treadmill
title_full_unstemmed Comparison of Peak Cardiopulmonary Performance Parameters on a Robotics-Assisted Tilt Table, a Cycle and a Treadmill
title_short Comparison of Peak Cardiopulmonary Performance Parameters on a Robotics-Assisted Tilt Table, a Cycle and a Treadmill
title_sort comparison of peak cardiopulmonary performance parameters on a robotics-assisted tilt table, a cycle and a treadmill
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4405815/
https://www.ncbi.nlm.nih.gov/pubmed/25860019
http://dx.doi.org/10.1371/journal.pone.0122767
work_keys_str_mv AT saengsuwanjittima comparisonofpeakcardiopulmonaryperformanceparametersonaroboticsassistedtilttableacycleandatreadmill
AT neftobias comparisonofpeakcardiopulmonaryperformanceparametersonaroboticsassistedtilttableacycleandatreadmill
AT laubachermarco comparisonofpeakcardiopulmonaryperformanceparametersonaroboticsassistedtilttableacycleandatreadmill
AT huntkennethj comparisonofpeakcardiopulmonaryperformanceparametersonaroboticsassistedtilttableacycleandatreadmill