Cargando…

A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells

The response and the reaction of the brain system to hypoxia is a vital research subject that requires special instrumentation. With this research subject in focus, a new multifunctional lab-on-a-chip (LOC) system with control over the oxygen content for studies on biological cells was developed. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Alrifaiy, Ahmed, Borg, Johan, Lindahl, Olof A, Ramser, Kerstin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4407798/
https://www.ncbi.nlm.nih.gov/pubmed/25907197
http://dx.doi.org/10.1186/s12938-015-0024-6
_version_ 1782367962812907520
author Alrifaiy, Ahmed
Borg, Johan
Lindahl, Olof A
Ramser, Kerstin
author_facet Alrifaiy, Ahmed
Borg, Johan
Lindahl, Olof A
Ramser, Kerstin
author_sort Alrifaiy, Ahmed
collection PubMed
description The response and the reaction of the brain system to hypoxia is a vital research subject that requires special instrumentation. With this research subject in focus, a new multifunctional lab-on-a-chip (LOC) system with control over the oxygen content for studies on biological cells was developed. The chip was designed to incorporate the patch clamp technique, optical tweezers and absorption spectroscopy. The performance of the LOC was tested by a series of experiments. The oxygen content within the channels of the LOC was monitored by an oxygen sensor and verified by simultaneously studying the oxygenation state of chicken red blood cells (RBCs) with absorption spectra. The chicken RBCs were manipulated optically and steered in three dimensions towards a patch-clamp micropipette in a closed microfluidic channel. The oxygen level within the channels could be changed from a normoxic value of 18% O (2) to an anoxic value of 0.0-0.5% O (2). A time series of 3 experiments were performed, showing that the spectral transfer from the oxygenated to the deoxygenated state occurred after about 227 ± 1 s and a fully developed deoxygenated spectrum was observed after 298 ± 1 s, a mean value of 3 experiments. The tightness of the chamber to oxygen diffusion was verified by stopping the flow into the channel system while continuously recording absorption spectra showing an unchanged deoxygenated state during 5400 ± 2 s. A transfer of the oxygenated absorption spectra was achieved after 426 ± 1 s when exposing the cell to normoxic buffer. This showed the long time viability of the investigated cells. Successful patching and sealing were established on a trapped RBC and the whole-cell access (Ra) and membrane (Rm) resistances were measured to be 5.033 ± 0.412 M Ω and 889.7 ± 1.74 M Ω respectively.
format Online
Article
Text
id pubmed-4407798
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-44077982015-04-24 A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells Alrifaiy, Ahmed Borg, Johan Lindahl, Olof A Ramser, Kerstin Biomed Eng Online Research The response and the reaction of the brain system to hypoxia is a vital research subject that requires special instrumentation. With this research subject in focus, a new multifunctional lab-on-a-chip (LOC) system with control over the oxygen content for studies on biological cells was developed. The chip was designed to incorporate the patch clamp technique, optical tweezers and absorption spectroscopy. The performance of the LOC was tested by a series of experiments. The oxygen content within the channels of the LOC was monitored by an oxygen sensor and verified by simultaneously studying the oxygenation state of chicken red blood cells (RBCs) with absorption spectra. The chicken RBCs were manipulated optically and steered in three dimensions towards a patch-clamp micropipette in a closed microfluidic channel. The oxygen level within the channels could be changed from a normoxic value of 18% O (2) to an anoxic value of 0.0-0.5% O (2). A time series of 3 experiments were performed, showing that the spectral transfer from the oxygenated to the deoxygenated state occurred after about 227 ± 1 s and a fully developed deoxygenated spectrum was observed after 298 ± 1 s, a mean value of 3 experiments. The tightness of the chamber to oxygen diffusion was verified by stopping the flow into the channel system while continuously recording absorption spectra showing an unchanged deoxygenated state during 5400 ± 2 s. A transfer of the oxygenated absorption spectra was achieved after 426 ± 1 s when exposing the cell to normoxic buffer. This showed the long time viability of the investigated cells. Successful patching and sealing were established on a trapped RBC and the whole-cell access (Ra) and membrane (Rm) resistances were measured to be 5.033 ± 0.412 M Ω and 889.7 ± 1.74 M Ω respectively. BioMed Central 2015-04-18 /pmc/articles/PMC4407798/ /pubmed/25907197 http://dx.doi.org/10.1186/s12938-015-0024-6 Text en © Alrifaiy et al.; licensee BioMed Central Ltd. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Alrifaiy, Ahmed
Borg, Johan
Lindahl, Olof A
Ramser, Kerstin
A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells
title A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells
title_full A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells
title_fullStr A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells
title_full_unstemmed A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells
title_short A lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells
title_sort lab-on-a-chip for hypoxic patch clamp measurements combined with optical tweezers and spectroscopy- first investigations of single biological cells
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4407798/
https://www.ncbi.nlm.nih.gov/pubmed/25907197
http://dx.doi.org/10.1186/s12938-015-0024-6
work_keys_str_mv AT alrifaiyahmed alabonachipforhypoxicpatchclampmeasurementscombinedwithopticaltweezersandspectroscopyfirstinvestigationsofsinglebiologicalcells
AT borgjohan alabonachipforhypoxicpatchclampmeasurementscombinedwithopticaltweezersandspectroscopyfirstinvestigationsofsinglebiologicalcells
AT lindahlolofa alabonachipforhypoxicpatchclampmeasurementscombinedwithopticaltweezersandspectroscopyfirstinvestigationsofsinglebiologicalcells
AT ramserkerstin alabonachipforhypoxicpatchclampmeasurementscombinedwithopticaltweezersandspectroscopyfirstinvestigationsofsinglebiologicalcells
AT alrifaiyahmed labonachipforhypoxicpatchclampmeasurementscombinedwithopticaltweezersandspectroscopyfirstinvestigationsofsinglebiologicalcells
AT borgjohan labonachipforhypoxicpatchclampmeasurementscombinedwithopticaltweezersandspectroscopyfirstinvestigationsofsinglebiologicalcells
AT lindahlolofa labonachipforhypoxicpatchclampmeasurementscombinedwithopticaltweezersandspectroscopyfirstinvestigationsofsinglebiologicalcells
AT ramserkerstin labonachipforhypoxicpatchclampmeasurementscombinedwithopticaltweezersandspectroscopyfirstinvestigationsofsinglebiologicalcells