Cargando…
View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application
BACKGROUND: MRI plays a major role in follow-up of patients with malignant bone tumors. However, after limb salvage surgery, orthopaedic tumor endoprostheses might cause significant metal-induced susceptibility artifacts. PURPOSES: To evaluate the benefit of view-angle tilting (VAT) and slice-encodi...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4409347/ https://www.ncbi.nlm.nih.gov/pubmed/25909472 http://dx.doi.org/10.1371/journal.pone.0124922 |
_version_ | 1782368186609434624 |
---|---|
author | Jungmann, Pia M. Ganter, Carl Schaeffeler, Christoph J. Bauer, Jan S. Baum, Thomas Meier, Reinhard Nittka, Mathias Pohlig, Florian Rechl, Hans von Eisenhart-Rothe, Ruediger Rummeny, Ernst J. Woertler, Klaus |
author_facet | Jungmann, Pia M. Ganter, Carl Schaeffeler, Christoph J. Bauer, Jan S. Baum, Thomas Meier, Reinhard Nittka, Mathias Pohlig, Florian Rechl, Hans von Eisenhart-Rothe, Ruediger Rummeny, Ernst J. Woertler, Klaus |
author_sort | Jungmann, Pia M. |
collection | PubMed |
description | BACKGROUND: MRI plays a major role in follow-up of patients with malignant bone tumors. However, after limb salvage surgery, orthopaedic tumor endoprostheses might cause significant metal-induced susceptibility artifacts. PURPOSES: To evaluate the benefit of view-angle tilting (VAT) and slice-encoding metal artifact correction (SEMAC) for MRI of large-sized orthopaedic tumor endoprostheses in an experimental model and to demonstrate clinical benefits for assessment of periprosthetic soft tissue abnormalities. METHODS: In an experimental setting, tumor endoprostheses (n=4) were scanned at 1.5T with three versions of optimized high-bandwidth turbo-spin-echo pulse sequences: (i) standard, (ii) VAT and (iii) combined VAT and SEMAC (VAT&SEMAC). Pulse sequences included coronal short-tau-inversion-recovery (STIR), coronal T1-weighted (w), transverse T1-w and T2-w TSE sequences. For clinical evaluation, VAT&SEMAC was compared to conventional metal artifact-reducing MR sequences (conventional MR) in n=25 patients with metal implants and clinical suspicion of tumor recurrence or infection. Diameters of artifacts were measured quantitatively. Qualitative parameters were assessed on a five-point scale (1=best, 5=worst): “image distortion”, “artificial signal changes at the edges” and “diagnostic confidence”. Imaging findings were correlated with pathology. T-tests and Wilcoxon-signed rank tests were used for statistical analyses. RESULTS: The true size of the prostheses was overestimated on MRI (P<0.05). A significant reduction of artifacts was achieved by VAT (P<0.001) and VAT&SEMAC (P=0.003) compared to the standard group. Quantitative scores improved in the VAT and VAT&SEMAC group (P<0.05). On clinical MR images, artifact diameters were significantly reduced in the VAT&SEMAC-group as compared with the conventional-group (P<0.001). Distortion and artificial signal changes were reduced and diagnostic confidence improved (P<0.05). In two cases, tumor-recurrence, in ten cases infection and in thirteen cases other pathologies were diagnosed. CONCLUSIONS: Significant reduction of metallic artifacts was achieved by VAT and SEMAC. Clinical results suggest, that these new techniques will be beneficial for detecting periprosthetic pathologies during postoperative follow-up. |
format | Online Article Text |
id | pubmed-4409347 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-44093472015-05-12 View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application Jungmann, Pia M. Ganter, Carl Schaeffeler, Christoph J. Bauer, Jan S. Baum, Thomas Meier, Reinhard Nittka, Mathias Pohlig, Florian Rechl, Hans von Eisenhart-Rothe, Ruediger Rummeny, Ernst J. Woertler, Klaus PLoS One Research Article BACKGROUND: MRI plays a major role in follow-up of patients with malignant bone tumors. However, after limb salvage surgery, orthopaedic tumor endoprostheses might cause significant metal-induced susceptibility artifacts. PURPOSES: To evaluate the benefit of view-angle tilting (VAT) and slice-encoding metal artifact correction (SEMAC) for MRI of large-sized orthopaedic tumor endoprostheses in an experimental model and to demonstrate clinical benefits for assessment of periprosthetic soft tissue abnormalities. METHODS: In an experimental setting, tumor endoprostheses (n=4) were scanned at 1.5T with three versions of optimized high-bandwidth turbo-spin-echo pulse sequences: (i) standard, (ii) VAT and (iii) combined VAT and SEMAC (VAT&SEMAC). Pulse sequences included coronal short-tau-inversion-recovery (STIR), coronal T1-weighted (w), transverse T1-w and T2-w TSE sequences. For clinical evaluation, VAT&SEMAC was compared to conventional metal artifact-reducing MR sequences (conventional MR) in n=25 patients with metal implants and clinical suspicion of tumor recurrence or infection. Diameters of artifacts were measured quantitatively. Qualitative parameters were assessed on a five-point scale (1=best, 5=worst): “image distortion”, “artificial signal changes at the edges” and “diagnostic confidence”. Imaging findings were correlated with pathology. T-tests and Wilcoxon-signed rank tests were used for statistical analyses. RESULTS: The true size of the prostheses was overestimated on MRI (P<0.05). A significant reduction of artifacts was achieved by VAT (P<0.001) and VAT&SEMAC (P=0.003) compared to the standard group. Quantitative scores improved in the VAT and VAT&SEMAC group (P<0.05). On clinical MR images, artifact diameters were significantly reduced in the VAT&SEMAC-group as compared with the conventional-group (P<0.001). Distortion and artificial signal changes were reduced and diagnostic confidence improved (P<0.05). In two cases, tumor-recurrence, in ten cases infection and in thirteen cases other pathologies were diagnosed. CONCLUSIONS: Significant reduction of metallic artifacts was achieved by VAT and SEMAC. Clinical results suggest, that these new techniques will be beneficial for detecting periprosthetic pathologies during postoperative follow-up. Public Library of Science 2015-04-24 /pmc/articles/PMC4409347/ /pubmed/25909472 http://dx.doi.org/10.1371/journal.pone.0124922 Text en © 2015 Jungmann et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Jungmann, Pia M. Ganter, Carl Schaeffeler, Christoph J. Bauer, Jan S. Baum, Thomas Meier, Reinhard Nittka, Mathias Pohlig, Florian Rechl, Hans von Eisenhart-Rothe, Ruediger Rummeny, Ernst J. Woertler, Klaus View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application |
title | View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application |
title_full | View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application |
title_fullStr | View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application |
title_full_unstemmed | View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application |
title_short | View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application |
title_sort | view-angle tilting and slice-encoding metal artifact correction for artifact reduction in mri: experimental sequence optimization for orthopaedic tumor endoprostheses and clinical application |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4409347/ https://www.ncbi.nlm.nih.gov/pubmed/25909472 http://dx.doi.org/10.1371/journal.pone.0124922 |
work_keys_str_mv | AT jungmannpiam viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT gantercarl viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT schaeffelerchristophj viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT bauerjans viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT baumthomas viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT meierreinhard viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT nittkamathias viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT pohligflorian viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT rechlhans viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT voneisenhartrotheruediger viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT rummenyernstj viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication AT woertlerklaus viewangletiltingandsliceencodingmetalartifactcorrectionforartifactreductioninmriexperimentalsequenceoptimizationfororthopaedictumorendoprosthesesandclinicalapplication |