Cargando…
Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study
BACKGROUND: Use of alkaline peroxide denture cleanser with different temperature of water could cause a change in surface hardness of the acrylic denture and also has a bleaching effect. The purpose of the study was to determine the effect of increased water content during thermal cycling of hot wat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dentmedpub Research and Printing Co
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4409799/ https://www.ncbi.nlm.nih.gov/pubmed/25954074 |
_version_ | 1782368240133996544 |
---|---|
author | Chandu, G S Asnani, Pooja Gupta, Siddarth Faisal Khan, Mohd. |
author_facet | Chandu, G S Asnani, Pooja Gupta, Siddarth Faisal Khan, Mohd. |
author_sort | Chandu, G S |
collection | PubMed |
description | BACKGROUND: Use of alkaline peroxide denture cleanser with different temperature of water could cause a change in surface hardness of the acrylic denture and also has a bleaching effect. The purpose of the study was to determine the effect of increased water content during thermal cycling of hot water-treated acrylic on the surface hardness of acrylic denture base when compared to warm water treated acrylic. And to compare the bleaching effect of alkaline peroxide solution on the acrylic denture base on hot water and warm water treated acrylic. MATERIALS AND METHODS: Forty samples (10 mm × 10 mm × 2.5 mm) were prepared. After the calculation of the initial hardness 40 samples, each was randomly assigned to two groups. Group A: 20 samples were immersed in 250 ml of warm distilled water at 40°C with alkaline peroxide tablet. Group B: 20 samples were immersed in 250 ml of hot distilled water at 100°C with alkaline peroxide tablet. The surface hardness of each test sample was obtained using the digital hardness testing machine recording the Rockwell hardness number before the beginning of the soaking cycles and after completion of 30 soak cycles and compared. Values were analyzed using paired t-test. Five samples from the Group A and five samples from Group B were put side by side and photographed using a Nikon D 40 digital SLR Camera and the photographs were examined visually to assess the change in color. RESULTS: Acrylic samples immersed in hot water showed a statistically significant decrease of 5.8% in surface hardness. And those immersed in warm water showed a statistically insignificant increase of 0.67% in surface hardness. Samples from the two groups showed clinically insignificant difference in color when compared to each other on examination of the photographs. CONCLUSION: Thermocycling of the acrylic resin at different water bath temperature at 40°C and 100°C showed significant changes in the surface hardness. |
format | Online Article Text |
id | pubmed-4409799 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Dentmedpub Research and Printing Co |
record_format | MEDLINE/PubMed |
spelling | pubmed-44097992015-06-01 Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study Chandu, G S Asnani, Pooja Gupta, Siddarth Faisal Khan, Mohd. J Int Oral Health Original Research BACKGROUND: Use of alkaline peroxide denture cleanser with different temperature of water could cause a change in surface hardness of the acrylic denture and also has a bleaching effect. The purpose of the study was to determine the effect of increased water content during thermal cycling of hot water-treated acrylic on the surface hardness of acrylic denture base when compared to warm water treated acrylic. And to compare the bleaching effect of alkaline peroxide solution on the acrylic denture base on hot water and warm water treated acrylic. MATERIALS AND METHODS: Forty samples (10 mm × 10 mm × 2.5 mm) were prepared. After the calculation of the initial hardness 40 samples, each was randomly assigned to two groups. Group A: 20 samples were immersed in 250 ml of warm distilled water at 40°C with alkaline peroxide tablet. Group B: 20 samples were immersed in 250 ml of hot distilled water at 100°C with alkaline peroxide tablet. The surface hardness of each test sample was obtained using the digital hardness testing machine recording the Rockwell hardness number before the beginning of the soaking cycles and after completion of 30 soak cycles and compared. Values were analyzed using paired t-test. Five samples from the Group A and five samples from Group B were put side by side and photographed using a Nikon D 40 digital SLR Camera and the photographs were examined visually to assess the change in color. RESULTS: Acrylic samples immersed in hot water showed a statistically significant decrease of 5.8% in surface hardness. And those immersed in warm water showed a statistically insignificant increase of 0.67% in surface hardness. Samples from the two groups showed clinically insignificant difference in color when compared to each other on examination of the photographs. CONCLUSION: Thermocycling of the acrylic resin at different water bath temperature at 40°C and 100°C showed significant changes in the surface hardness. Dentmedpub Research and Printing Co 2015-04 /pmc/articles/PMC4409799/ /pubmed/25954074 Text en Copyright: © Journal of International Oral Health http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Research Chandu, G S Asnani, Pooja Gupta, Siddarth Faisal Khan, Mohd. Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study |
title | Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study |
title_full | Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study |
title_fullStr | Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study |
title_full_unstemmed | Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study |
title_short | Comparative Evaluation of Effect of Water Absorption on the Surface Properties of Heat Cure Acrylic: An in vitro Study |
title_sort | comparative evaluation of effect of water absorption on the surface properties of heat cure acrylic: an in vitro study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4409799/ https://www.ncbi.nlm.nih.gov/pubmed/25954074 |
work_keys_str_mv | AT chandugs comparativeevaluationofeffectofwaterabsorptiononthesurfacepropertiesofheatcureacrylicaninvitrostudy AT asnanipooja comparativeevaluationofeffectofwaterabsorptiononthesurfacepropertiesofheatcureacrylicaninvitrostudy AT guptasiddarth comparativeevaluationofeffectofwaterabsorptiononthesurfacepropertiesofheatcureacrylicaninvitrostudy AT faisalkhanmohd comparativeevaluationofeffectofwaterabsorptiononthesurfacepropertiesofheatcureacrylicaninvitrostudy |