Cargando…

Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T

Gas calibrated fMRI in its most common form uses hypercapnia in conjunction with the Davis model to quantify relative changes in the cerebral rate of oxygen consumption (CMRO(2)) in response to a functional stimulus. It is most commonly carried out at 3 T but, as 7 T research scanners are becoming m...

Descripción completa

Detalles Bibliográficos
Autores principales: Hare, Hannah V., Blockley, Nicholas P., Gardener, Alexander G., Clare, Stuart, Bulte, Daniel P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Academic Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4410945/
https://www.ncbi.nlm.nih.gov/pubmed/25783207
http://dx.doi.org/10.1016/j.neuroimage.2015.02.068
_version_ 1782368391905935360
author Hare, Hannah V.
Blockley, Nicholas P.
Gardener, Alexander G.
Clare, Stuart
Bulte, Daniel P.
author_facet Hare, Hannah V.
Blockley, Nicholas P.
Gardener, Alexander G.
Clare, Stuart
Bulte, Daniel P.
author_sort Hare, Hannah V.
collection PubMed
description Gas calibrated fMRI in its most common form uses hypercapnia in conjunction with the Davis model to quantify relative changes in the cerebral rate of oxygen consumption (CMRO(2)) in response to a functional stimulus. It is most commonly carried out at 3 T but, as 7 T research scanners are becoming more widespread and the majority of clinical scanners are still 1.5 T systems, it is important to investigate whether the model used remains accurate across this range of field strengths. Ten subjects were scanned at 1.5, 3 and 7 T whilst performing a bilateral finger-tapping task as part of a calibrated fMRI protocol, and the results were compared to a detailed signal model. Simulations predicted an increase in value and variation in the calibration parameter M with field strength. Two methods of defining experimental regions of interest (ROIs) were investigated, based on (a) BOLD signal and (b) BOLD responses within grey matter only. M values from the latter ROI were in closer agreement with theoretical predictions; however, reassuringly, ROI choice had less impact on CMRO(2) than on M estimates. Relative changes in CMRO(2) during motor tasks at 3 and 7 T were in good agreement but were over-estimated at 1.5 T as a result of the lower signal to noise ratio. This result is encouraging for future studies at 7 T, but also highlights the impact of imaging and analysis choices (such as ASL sequence and ROI definition) on the calibration parameter M and on the calculation of CMRO(2).
format Online
Article
Text
id pubmed-4410945
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Academic Press
record_format MEDLINE/PubMed
spelling pubmed-44109452015-05-15 Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T Hare, Hannah V. Blockley, Nicholas P. Gardener, Alexander G. Clare, Stuart Bulte, Daniel P. Neuroimage Article Gas calibrated fMRI in its most common form uses hypercapnia in conjunction with the Davis model to quantify relative changes in the cerebral rate of oxygen consumption (CMRO(2)) in response to a functional stimulus. It is most commonly carried out at 3 T but, as 7 T research scanners are becoming more widespread and the majority of clinical scanners are still 1.5 T systems, it is important to investigate whether the model used remains accurate across this range of field strengths. Ten subjects were scanned at 1.5, 3 and 7 T whilst performing a bilateral finger-tapping task as part of a calibrated fMRI protocol, and the results were compared to a detailed signal model. Simulations predicted an increase in value and variation in the calibration parameter M with field strength. Two methods of defining experimental regions of interest (ROIs) were investigated, based on (a) BOLD signal and (b) BOLD responses within grey matter only. M values from the latter ROI were in closer agreement with theoretical predictions; however, reassuringly, ROI choice had less impact on CMRO(2) than on M estimates. Relative changes in CMRO(2) during motor tasks at 3 and 7 T were in good agreement but were over-estimated at 1.5 T as a result of the lower signal to noise ratio. This result is encouraging for future studies at 7 T, but also highlights the impact of imaging and analysis choices (such as ASL sequence and ROI definition) on the calibration parameter M and on the calculation of CMRO(2). Academic Press 2015-05-15 /pmc/articles/PMC4410945/ /pubmed/25783207 http://dx.doi.org/10.1016/j.neuroimage.2015.02.068 Text en © 2015 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hare, Hannah V.
Blockley, Nicholas P.
Gardener, Alexander G.
Clare, Stuart
Bulte, Daniel P.
Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T
title Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T
title_full Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T
title_fullStr Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T
title_full_unstemmed Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T
title_short Investigating the field-dependence of the Davis model: Calibrated fMRI at 1.5, 3 and 7 T
title_sort investigating the field-dependence of the davis model: calibrated fmri at 1.5, 3 and 7 t
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4410945/
https://www.ncbi.nlm.nih.gov/pubmed/25783207
http://dx.doi.org/10.1016/j.neuroimage.2015.02.068
work_keys_str_mv AT harehannahv investigatingthefielddependenceofthedavismodelcalibratedfmriat153and7t
AT blockleynicholasp investigatingthefielddependenceofthedavismodelcalibratedfmriat153and7t
AT gardeneralexanderg investigatingthefielddependenceofthedavismodelcalibratedfmriat153and7t
AT clarestuart investigatingthefielddependenceofthedavismodelcalibratedfmriat153and7t
AT bultedanielp investigatingthefielddependenceofthedavismodelcalibratedfmriat153and7t