Cargando…

A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting

BACKGROUND: Successful restoration of structure and function using autologous free fat grafts has remained elusive. Review of literature shows that various harvesting and preparation techniques have been suggested. The goal of these techniques is to obtain greater adipocyte cell survival and consequ...

Descripción completa

Detalles Bibliográficos
Autores principales: Ashok, B. C., Nagaraj, Pradeep Kumar, Ananteshwar, Y. N., Srikanth, V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4413496/
https://www.ncbi.nlm.nih.gov/pubmed/25991892
http://dx.doi.org/10.4103/0970-0358.155275
_version_ 1782368789038366720
author Ashok, B. C.
Nagaraj, Pradeep Kumar
Ananteshwar, Y. N.
Srikanth, V.
author_facet Ashok, B. C.
Nagaraj, Pradeep Kumar
Ananteshwar, Y. N.
Srikanth, V.
author_sort Ashok, B. C.
collection PubMed
description BACKGROUND: Successful restoration of structure and function using autologous free fat grafts has remained elusive. Review of literature shows that various harvesting and preparation techniques have been suggested. The goal of these techniques is to obtain greater adipocyte cell survival and consequently more reliable clinical results. MATERIALS AND METHODS: In our technique, a piece of mesh is kept at one end of the lipoaspiration syringe, which is then connected to the Suction pump. As one syringe fills, it is replaced by another one until the required amount of fat is obtained. RESULTS: By using a polypropylene mesh in our technique, we can separate the transfusate from the harvested fat graft during harvesting itself. The fat graft thus obtained is dense and concentrated, with fewer impurities. CONCLUSION: Hence, we recommend our technique as a reliable method for extracting sterile emulsified fat in an economical way.
format Online
Article
Text
id pubmed-4413496
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-44134962015-05-19 A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting Ashok, B. C. Nagaraj, Pradeep Kumar Ananteshwar, Y. N. Srikanth, V. Indian J Plast Surg Ideas and Innovations BACKGROUND: Successful restoration of structure and function using autologous free fat grafts has remained elusive. Review of literature shows that various harvesting and preparation techniques have been suggested. The goal of these techniques is to obtain greater adipocyte cell survival and consequently more reliable clinical results. MATERIALS AND METHODS: In our technique, a piece of mesh is kept at one end of the lipoaspiration syringe, which is then connected to the Suction pump. As one syringe fills, it is replaced by another one until the required amount of fat is obtained. RESULTS: By using a polypropylene mesh in our technique, we can separate the transfusate from the harvested fat graft during harvesting itself. The fat graft thus obtained is dense and concentrated, with fewer impurities. CONCLUSION: Hence, we recommend our technique as a reliable method for extracting sterile emulsified fat in an economical way. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4413496/ /pubmed/25991892 http://dx.doi.org/10.4103/0970-0358.155275 Text en Copyright: © Indian Journal of Plastic Surgery http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Ideas and Innovations
Ashok, B. C.
Nagaraj, Pradeep Kumar
Ananteshwar, Y. N.
Srikanth, V.
A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting
title A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting
title_full A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting
title_fullStr A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting
title_full_unstemmed A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting
title_short A novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting
title_sort novel and innovative technique of using a disposable syringe and mesh for harvesting fat for structural fat grafting
topic Ideas and Innovations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4413496/
https://www.ncbi.nlm.nih.gov/pubmed/25991892
http://dx.doi.org/10.4103/0970-0358.155275
work_keys_str_mv AT ashokbc anovelandinnovativetechniqueofusingadisposablesyringeandmeshforharvestingfatforstructuralfatgrafting
AT nagarajpradeepkumar anovelandinnovativetechniqueofusingadisposablesyringeandmeshforharvestingfatforstructuralfatgrafting
AT ananteshwaryn anovelandinnovativetechniqueofusingadisposablesyringeandmeshforharvestingfatforstructuralfatgrafting
AT srikanthv anovelandinnovativetechniqueofusingadisposablesyringeandmeshforharvestingfatforstructuralfatgrafting
AT ashokbc novelandinnovativetechniqueofusingadisposablesyringeandmeshforharvestingfatforstructuralfatgrafting
AT nagarajpradeepkumar novelandinnovativetechniqueofusingadisposablesyringeandmeshforharvestingfatforstructuralfatgrafting
AT ananteshwaryn novelandinnovativetechniqueofusingadisposablesyringeandmeshforharvestingfatforstructuralfatgrafting
AT srikanthv novelandinnovativetechniqueofusingadisposablesyringeandmeshforharvestingfatforstructuralfatgrafting