Non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments
BACKGROUND AND OBJECTIVES: A sharply contoured cryolipolysis vacuum applicator was developed to improve fit and tissue draw in the abdomen and flanks to better accommodate a range of body types and a variety of treatment sites. This study was carried out to evaluate the safety and efficacy of the ne...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BlackWell Publishing Ltd
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4413829/ https://www.ncbi.nlm.nih.gov/pubmed/25395266 http://dx.doi.org/10.1002/lsm.22302 |
_version_ | 1782368843202560000 |
---|---|
author | Bernstein, Eric F Bloom, Jason D Basilavecchio, Lisa D Plugis, Jessica M |
author_facet | Bernstein, Eric F Bloom, Jason D Basilavecchio, Lisa D Plugis, Jessica M |
author_sort | Bernstein, Eric F |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: A sharply contoured cryolipolysis vacuum applicator was developed to improve fit and tissue draw in the abdomen and flanks to better accommodate a range of body types and a variety of treatment sites. This study was carried out to evaluate the safety and efficacy of the new applicator for treatment of flank fat (“love handles”). STUDY DESIGN/MATERIALS AND METHODS: A cryolipolysis vacuum applicator with a sharply contoured cup and curved cooling plates was used to treat 20 flanks. Two treatment cycles were delivered sequentially to each flank (60-minute cycle at a Cooling Intensity Factor of 41.6). Efficacy was evaluated 12 weeks post-treatment by physicians performing blinded, independent review of clinical photographs. Safety was assessed by the treating physician monitoring subjects for side effects and adverse events. RESULTS: Four blinded, independent physician reviewers properly identified the pre- and post-treatment photographs 94.4% of the time. Improvement was scored from 0 (none) to 10 (complete) and showed an average 4.3 point (43%) improvement. Side-effects were limited to erythema, edema, bruising, and numbness or tingling at the treatment site, and resolved without treatment. CONCLUSIONS: Multiple treatment cycles from a new improved-fit cryolipolysis applicator are safe and effective for reduction of flank fat bulges. A high degree of improvement was reported by blinded, physician evaluation of standardized photographs. Laser Surg. Med. 46:731–735, 2014. © 2014 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals, Inc. |
format | Online Article Text |
id | pubmed-4413829 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BlackWell Publishing Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-44138292015-05-05 Non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments Bernstein, Eric F Bloom, Jason D Basilavecchio, Lisa D Plugis, Jessica M Lasers Surg Med Clinical Reports BACKGROUND AND OBJECTIVES: A sharply contoured cryolipolysis vacuum applicator was developed to improve fit and tissue draw in the abdomen and flanks to better accommodate a range of body types and a variety of treatment sites. This study was carried out to evaluate the safety and efficacy of the new applicator for treatment of flank fat (“love handles”). STUDY DESIGN/MATERIALS AND METHODS: A cryolipolysis vacuum applicator with a sharply contoured cup and curved cooling plates was used to treat 20 flanks. Two treatment cycles were delivered sequentially to each flank (60-minute cycle at a Cooling Intensity Factor of 41.6). Efficacy was evaluated 12 weeks post-treatment by physicians performing blinded, independent review of clinical photographs. Safety was assessed by the treating physician monitoring subjects for side effects and adverse events. RESULTS: Four blinded, independent physician reviewers properly identified the pre- and post-treatment photographs 94.4% of the time. Improvement was scored from 0 (none) to 10 (complete) and showed an average 4.3 point (43%) improvement. Side-effects were limited to erythema, edema, bruising, and numbness or tingling at the treatment site, and resolved without treatment. CONCLUSIONS: Multiple treatment cycles from a new improved-fit cryolipolysis applicator are safe and effective for reduction of flank fat bulges. A high degree of improvement was reported by blinded, physician evaluation of standardized photographs. Laser Surg. Med. 46:731–735, 2014. © 2014 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals, Inc. BlackWell Publishing Ltd 2014-12 2014-11-13 /pmc/articles/PMC4413829/ /pubmed/25395266 http://dx.doi.org/10.1002/lsm.22302 Text en © 2014 The Authors. Lasers in Surgery and Medicine published by Wiley Periodicals, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Clinical Reports Bernstein, Eric F Bloom, Jason D Basilavecchio, Lisa D Plugis, Jessica M Non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments |
title | Non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments |
title_full | Non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments |
title_fullStr | Non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments |
title_full_unstemmed | Non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments |
title_short | Non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments |
title_sort | non-invasive fat reduction of the flanks using a new cryolipolysis applicator and overlapping, two-cycle treatments |
topic | Clinical Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4413829/ https://www.ncbi.nlm.nih.gov/pubmed/25395266 http://dx.doi.org/10.1002/lsm.22302 |
work_keys_str_mv | AT bernsteinericf noninvasivefatreductionoftheflanksusinganewcryolipolysisapplicatorandoverlappingtwocycletreatments AT bloomjasond noninvasivefatreductionoftheflanksusinganewcryolipolysisapplicatorandoverlappingtwocycletreatments AT basilavecchiolisad noninvasivefatreductionoftheflanksusinganewcryolipolysisapplicatorandoverlappingtwocycletreatments AT plugisjessicam noninvasivefatreductionoftheflanksusinganewcryolipolysisapplicatorandoverlappingtwocycletreatments |