Cargando…

Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies

BACKGROUND: There is increasing interest in using smartphones as stand-alone physical activity monitors via their built-in accelerometers, but there is presently limited data on the validity of this approach. OBJECTIVE: The purpose of this work was to determine the validity and reliability of 3 Andr...

Descripción completa

Detalles Bibliográficos
Autores principales: Hekler, Eric B, Buman, Matthew P, Grieco, Lauren, Rosenberger, Mary, Winter, Sandra J, Haskell, William, King, Abby C
Formato: Online Artículo Texto
Lenguaje:English
Publicado: JMIR Publications Inc. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4414958/
https://www.ncbi.nlm.nih.gov/pubmed/25881662
http://dx.doi.org/10.2196/mhealth.3505
_version_ 1782369004959039488
author Hekler, Eric B
Buman, Matthew P
Grieco, Lauren
Rosenberger, Mary
Winter, Sandra J
Haskell, William
King, Abby C
author_facet Hekler, Eric B
Buman, Matthew P
Grieco, Lauren
Rosenberger, Mary
Winter, Sandra J
Haskell, William
King, Abby C
author_sort Hekler, Eric B
collection PubMed
description BACKGROUND: There is increasing interest in using smartphones as stand-alone physical activity monitors via their built-in accelerometers, but there is presently limited data on the validity of this approach. OBJECTIVE: The purpose of this work was to determine the validity and reliability of 3 Android smartphones for measuring physical activity among midlife and older adults. METHODS: A laboratory (study 1) and a free-living (study 2) protocol were conducted. In study 1, individuals engaged in prescribed activities including sedentary (eg, sitting), light (sweeping), moderate (eg, walking 3 mph on a treadmill), and vigorous (eg, jogging 5 mph on a treadmill) activity over a 2-hour period wearing both an ActiGraph and 3 Android smartphones (ie, HTC MyTouch, Google Nexus One, and Motorola Cliq). In the free-living study, individuals engaged in usual daily activities over 7 days while wearing an Android smartphone (Google Nexus One) and an ActiGraph. RESULTS: Study 1 included 15 participants (age: mean 55.5, SD 6.6 years; women: 56%, 8/15). Correlations between the ActiGraph and the 3 phones were strong to very strong (ρ=.77-.82). Further, after excluding bicycling and standing, cut-point derived classifications of activities yielded a high percentage of activities classified correctly according to intensity level (eg, 78%-91% by phone) that were similar to the ActiGraph’s percent correctly classified (ie, 91%). Study 2 included 23 participants (age: mean 57.0, SD 6.4 years; women: 74%, 17/23). Within the free-living context, results suggested a moderate correlation (ie, ρ=.59, P<.001) between the raw ActiGraph counts/minute and the phone’s raw counts/minute and a strong correlation on minutes of moderate-to-vigorous physical activity (MVPA; ie, ρ=.67, P<.001). Results from Bland-Altman plots suggested close mean absolute estimates of sedentary (mean difference=–26 min/day of sedentary behavior) and MVPA (mean difference=–1.3 min/day of MVPA) although there was large variation. CONCLUSIONS: Overall, results suggest that an Android smartphone can provide comparable estimates of physical activity to an ActiGraph in both a laboratory-based and free-living context for estimating sedentary and MVPA and that different Android smartphones may reliably confer similar estimates.
format Online
Article
Text
id pubmed-4414958
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher JMIR Publications Inc.
record_format MEDLINE/PubMed
spelling pubmed-44149582015-05-08 Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies Hekler, Eric B Buman, Matthew P Grieco, Lauren Rosenberger, Mary Winter, Sandra J Haskell, William King, Abby C JMIR Mhealth Uhealth Original Paper BACKGROUND: There is increasing interest in using smartphones as stand-alone physical activity monitors via their built-in accelerometers, but there is presently limited data on the validity of this approach. OBJECTIVE: The purpose of this work was to determine the validity and reliability of 3 Android smartphones for measuring physical activity among midlife and older adults. METHODS: A laboratory (study 1) and a free-living (study 2) protocol were conducted. In study 1, individuals engaged in prescribed activities including sedentary (eg, sitting), light (sweeping), moderate (eg, walking 3 mph on a treadmill), and vigorous (eg, jogging 5 mph on a treadmill) activity over a 2-hour period wearing both an ActiGraph and 3 Android smartphones (ie, HTC MyTouch, Google Nexus One, and Motorola Cliq). In the free-living study, individuals engaged in usual daily activities over 7 days while wearing an Android smartphone (Google Nexus One) and an ActiGraph. RESULTS: Study 1 included 15 participants (age: mean 55.5, SD 6.6 years; women: 56%, 8/15). Correlations between the ActiGraph and the 3 phones were strong to very strong (ρ=.77-.82). Further, after excluding bicycling and standing, cut-point derived classifications of activities yielded a high percentage of activities classified correctly according to intensity level (eg, 78%-91% by phone) that were similar to the ActiGraph’s percent correctly classified (ie, 91%). Study 2 included 23 participants (age: mean 57.0, SD 6.4 years; women: 74%, 17/23). Within the free-living context, results suggested a moderate correlation (ie, ρ=.59, P<.001) between the raw ActiGraph counts/minute and the phone’s raw counts/minute and a strong correlation on minutes of moderate-to-vigorous physical activity (MVPA; ie, ρ=.67, P<.001). Results from Bland-Altman plots suggested close mean absolute estimates of sedentary (mean difference=–26 min/day of sedentary behavior) and MVPA (mean difference=–1.3 min/day of MVPA) although there was large variation. CONCLUSIONS: Overall, results suggest that an Android smartphone can provide comparable estimates of physical activity to an ActiGraph in both a laboratory-based and free-living context for estimating sedentary and MVPA and that different Android smartphones may reliably confer similar estimates. JMIR Publications Inc. 2015-04-15 /pmc/articles/PMC4414958/ /pubmed/25881662 http://dx.doi.org/10.2196/mhealth.3505 Text en ©Eric B Hekler, Matthew P Buman, Lauren Grieco, Mary Rosenberger, Sandra J Winter, William Haskell, Abby C King. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 15.04.2015. http://creativecommons.org/licenses/by/2.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in JMIR mhealth and uhealth, is properly cited. The complete bibliographic information, a link to the original publication on http://mhealth.jmir.org/, as well as this copyright and license information must be included.
spellingShingle Original Paper
Hekler, Eric B
Buman, Matthew P
Grieco, Lauren
Rosenberger, Mary
Winter, Sandra J
Haskell, William
King, Abby C
Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies
title Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies
title_full Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies
title_fullStr Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies
title_full_unstemmed Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies
title_short Validation of Physical Activity Tracking via Android Smartphones Compared to ActiGraph Accelerometer: Laboratory-Based and Free-Living Validation Studies
title_sort validation of physical activity tracking via android smartphones compared to actigraph accelerometer: laboratory-based and free-living validation studies
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4414958/
https://www.ncbi.nlm.nih.gov/pubmed/25881662
http://dx.doi.org/10.2196/mhealth.3505
work_keys_str_mv AT heklerericb validationofphysicalactivitytrackingviaandroidsmartphonescomparedtoactigraphaccelerometerlaboratorybasedandfreelivingvalidationstudies
AT bumanmatthewp validationofphysicalactivitytrackingviaandroidsmartphonescomparedtoactigraphaccelerometerlaboratorybasedandfreelivingvalidationstudies
AT griecolauren validationofphysicalactivitytrackingviaandroidsmartphonescomparedtoactigraphaccelerometerlaboratorybasedandfreelivingvalidationstudies
AT rosenbergermary validationofphysicalactivitytrackingviaandroidsmartphonescomparedtoactigraphaccelerometerlaboratorybasedandfreelivingvalidationstudies
AT wintersandraj validationofphysicalactivitytrackingviaandroidsmartphonescomparedtoactigraphaccelerometerlaboratorybasedandfreelivingvalidationstudies
AT haskellwilliam validationofphysicalactivitytrackingviaandroidsmartphonescomparedtoactigraphaccelerometerlaboratorybasedandfreelivingvalidationstudies
AT kingabbyc validationofphysicalactivitytrackingviaandroidsmartphonescomparedtoactigraphaccelerometerlaboratorybasedandfreelivingvalidationstudies