BACKGROUND: Rapid influenza diagnostic tests (RIDTs) have an important role in clinical decision-making; however, the performances of currently available assays vary widely. OBJECTIVES: We evaluated the performance of the Alere™ i Influenza A&B (Alere™ iNAT), a rapid isothermal nucleic acid ampl...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BlackWell Publishing Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4415699/ https://www.ncbi.nlm.nih.gov/pubmed/25728758 http://dx.doi.org/10.1111/irv.12303 |
Sumario: | BACKGROUND: Rapid influenza diagnostic tests (RIDTs) have an important role in clinical decision-making; however, the performances of currently available assays vary widely. OBJECTIVES: We evaluated the performance of the Alere™ i Influenza A&B (Alere™ iNAT), a rapid isothermal nucleic acid amplification assay that has recently received FDA clearance, for the detection of influenza A and B viruses during the Australian influenza season of 2013. Results were compared to two other RIDTs tested in parallel; Quidel Sofia® Influenza A+B fluorescent immunoassay (FIA) and Alere™ BinaxNOW® Influenza A & B immunochromatographic (ICT) assay. METHODS: A total of 202 paired nasopharyngeal swabs collected from patients ≥16 years old with an influenza-like illness (ILI) were eluted in 2 ml of universal transport medium (UTM) that was used to perform all three RIDTs in parallel. Reverse-transcription polymerase chain reaction (RT-PCR) was used as the reference standard. RESULTS: Compared to RT-PCR, Alere™ iNAT detected 77·8% influenza A positive samples versus 71·4% and 44·4% for the Quidel Sofia® Influenza A+B FIA and BinaxNOW® Influenza A & B ICT assay, respectively. For influenza B, Alere™ iNAT detected 75% of those positive by RT-PCR, versus 33·3% and 25·0% for Sofia® and BinaxNOW®, respectively. The specificity of Alere™ iNAT was 100% for influenza A and 99% for influenza B. CONCLUSIONS: Alere™ i Influenza A&B is a promising new rapid influenza diagnostic assay with potential point-of-care applications. |
---|