Cargando…
Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques
BACKGROUND: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. OBJECTIVES: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascul...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Cardiologia
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4415868/ https://www.ncbi.nlm.nih.gov/pubmed/25993595 http://dx.doi.org/10.5935/abc.20140211 |
_version_ | 1782369141703835648 |
---|---|
author | Falcão, João L. A. A. Falcão, Breno A. A. Gurudevan, Swaminatha V. Campos, Carlos M. Silva, Expedito R. Kalil-Filho, Roberto Rochitte, Carlos E. Shiozaki, Afonso A. Coelho-Filho, Otavio R. Lemos, Pedro A. |
author_facet | Falcão, João L. A. A. Falcão, Breno A. A. Gurudevan, Swaminatha V. Campos, Carlos M. Silva, Expedito R. Kalil-Filho, Roberto Rochitte, Carlos E. Shiozaki, Afonso A. Coelho-Filho, Otavio R. Lemos, Pedro A. |
author_sort | Falcão, João L. A. A. |
collection | PubMed |
description | BACKGROUND: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. OBJECTIVES: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. METHODS: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. RESULTS: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. CONCLUSIONS: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques. |
format | Online Article Text |
id | pubmed-4415868 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Sociedade Brasileira de Cardiologia |
record_format | MEDLINE/PubMed |
spelling | pubmed-44158682015-05-04 Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques Falcão, João L. A. A. Falcão, Breno A. A. Gurudevan, Swaminatha V. Campos, Carlos M. Silva, Expedito R. Kalil-Filho, Roberto Rochitte, Carlos E. Shiozaki, Afonso A. Coelho-Filho, Otavio R. Lemos, Pedro A. Arq Bras Cardiol Original Articles BACKGROUND: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. OBJECTIVES: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. METHODS: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. RESULTS: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. CONCLUSIONS: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques. Sociedade Brasileira de Cardiologia 2015-04 /pmc/articles/PMC4415868/ /pubmed/25993595 http://dx.doi.org/10.5935/abc.20140211 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Falcão, João L. A. A. Falcão, Breno A. A. Gurudevan, Swaminatha V. Campos, Carlos M. Silva, Expedito R. Kalil-Filho, Roberto Rochitte, Carlos E. Shiozaki, Afonso A. Coelho-Filho, Otavio R. Lemos, Pedro A. Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of Coronary Lumen in Segments with or without Atherosclerotic Plaques |
title | Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of
Coronary Lumen in Segments with or without Atherosclerotic Plaques |
title_full | Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of
Coronary Lumen in Segments with or without Atherosclerotic Plaques |
title_fullStr | Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of
Coronary Lumen in Segments with or without Atherosclerotic Plaques |
title_full_unstemmed | Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of
Coronary Lumen in Segments with or without Atherosclerotic Plaques |
title_short | Comparison between MDCT and Grayscale IVUS in a Quantitative Analysis of
Coronary Lumen in Segments with or without Atherosclerotic Plaques |
title_sort | comparison between mdct and grayscale ivus in a quantitative analysis of
coronary lumen in segments with or without atherosclerotic plaques |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4415868/ https://www.ncbi.nlm.nih.gov/pubmed/25993595 http://dx.doi.org/10.5935/abc.20140211 |
work_keys_str_mv | AT falcaojoaolaa comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT falcaobrenoaa comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT gurudevanswaminathav comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT camposcarlosm comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT silvaexpeditor comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT kalilfilhoroberto comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT rochittecarlose comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT shiozakiafonsoa comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT coelhofilhootavior comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques AT lemospedroa comparisonbetweenmdctandgrayscaleivusinaquantitativeanalysisofcoronarylumeninsegmentswithorwithoutatheroscleroticplaques |