Cargando…

Influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor

The influence of mass transfer on productivity as well as the performance of packed bed bioreactor was determined by varying a number of parameters; flow rate, glucose concentration and polymers (chitosan). Saccharomyces cerevisiae cells were immobilized in chitosan and non-chitosan coated alginate...

Descripción completa

Detalles Bibliográficos
Autores principales: Hussain, Amir, Kangwa, Martin, Abo-Elwafa, Ahmed Gad, Fernandez-Lahore, Marcelo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4416096/
https://www.ncbi.nlm.nih.gov/pubmed/25977875
http://dx.doi.org/10.1186/s13568-015-0111-x
_version_ 1782369180091154432
author Hussain, Amir
Kangwa, Martin
Abo-Elwafa, Ahmed Gad
Fernandez-Lahore, Marcelo
author_facet Hussain, Amir
Kangwa, Martin
Abo-Elwafa, Ahmed Gad
Fernandez-Lahore, Marcelo
author_sort Hussain, Amir
collection PubMed
description The influence of mass transfer on productivity as well as the performance of packed bed bioreactor was determined by varying a number of parameters; flow rate, glucose concentration and polymers (chitosan). Saccharomyces cerevisiae cells were immobilized in chitosan and non-chitosan coated alginate beads to demonstrate the effect on external mass transfer by substrate consumption time, lag phase and ethanol production. The results indicate that coating has a significant effect on the lag phase duration, being 30–40 min higher than non-coated beads. After lag phase, no significant change was observed in both types of beads on consumption of glucose with the same flow rate. It was observed that by increasing flow rates; lag phase and glucose consumption time decreased. The reason is due to the reduction of external mass transfer as a result of increase in flow rate as glucose is easily transported to and from the beads surface by diffusion. It is observed that chitosan acts as barrier for transfer of substrate and products, in and out of beads, at initial time of fermentation as it shows longer lag phase for chitosan coated beads than non-coated. Glucose consumption at low flow rate was lower as compared to higher flow rates. The optimum combination of parameters consisting of higher flow rates 30–90 ml/min and between 10 and 20 g/l of glucose was found for maximum production of ethanol.
format Online
Article
Text
id pubmed-4416096
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-44160962015-05-14 Influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor Hussain, Amir Kangwa, Martin Abo-Elwafa, Ahmed Gad Fernandez-Lahore, Marcelo AMB Express Original Article The influence of mass transfer on productivity as well as the performance of packed bed bioreactor was determined by varying a number of parameters; flow rate, glucose concentration and polymers (chitosan). Saccharomyces cerevisiae cells were immobilized in chitosan and non-chitosan coated alginate beads to demonstrate the effect on external mass transfer by substrate consumption time, lag phase and ethanol production. The results indicate that coating has a significant effect on the lag phase duration, being 30–40 min higher than non-coated beads. After lag phase, no significant change was observed in both types of beads on consumption of glucose with the same flow rate. It was observed that by increasing flow rates; lag phase and glucose consumption time decreased. The reason is due to the reduction of external mass transfer as a result of increase in flow rate as glucose is easily transported to and from the beads surface by diffusion. It is observed that chitosan acts as barrier for transfer of substrate and products, in and out of beads, at initial time of fermentation as it shows longer lag phase for chitosan coated beads than non-coated. Glucose consumption at low flow rate was lower as compared to higher flow rates. The optimum combination of parameters consisting of higher flow rates 30–90 ml/min and between 10 and 20 g/l of glucose was found for maximum production of ethanol. Springer Berlin Heidelberg 2015-05-01 /pmc/articles/PMC4416096/ /pubmed/25977875 http://dx.doi.org/10.1186/s13568-015-0111-x Text en © Hussain et al.; licensee Springer. 2015 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Hussain, Amir
Kangwa, Martin
Abo-Elwafa, Ahmed Gad
Fernandez-Lahore, Marcelo
Influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor
title Influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor
title_full Influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor
title_fullStr Influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor
title_full_unstemmed Influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor
title_short Influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor
title_sort influence of operational parameters on the fluid-side mass transfer resistance observed in a packed bed bioreactor
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4416096/
https://www.ncbi.nlm.nih.gov/pubmed/25977875
http://dx.doi.org/10.1186/s13568-015-0111-x
work_keys_str_mv AT hussainamir influenceofoperationalparametersonthefluidsidemasstransferresistanceobservedinapackedbedbioreactor
AT kangwamartin influenceofoperationalparametersonthefluidsidemasstransferresistanceobservedinapackedbedbioreactor
AT aboelwafaahmedgad influenceofoperationalparametersonthefluidsidemasstransferresistanceobservedinapackedbedbioreactor
AT fernandezlahoremarcelo influenceofoperationalparametersonthefluidsidemasstransferresistanceobservedinapackedbedbioreactor