Cargando…
Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit
BACKGROUND: Continuous Glucose Monitoring (CGM) has become an increasingly investigated tool, especially with regards to monitoring of diabetic and critical care patients. The continuous glucose data allows the calculation of several glucose variability parameters, however, without specific applicat...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4416329/ https://www.ncbi.nlm.nih.gov/pubmed/25907677 http://dx.doi.org/10.1186/s12938-015-0035-3 |
_version_ | 1782369219128590336 |
---|---|
author | Marics, Gábor Lendvai, Zsófia Lódi, Csaba Koncz, Levente Zakariás, Dávid Schuster, György Mikos, Borbála Hermann, Csaba Szabó, Attila J Tóth-Heyn, Péter |
author_facet | Marics, Gábor Lendvai, Zsófia Lódi, Csaba Koncz, Levente Zakariás, Dávid Schuster, György Mikos, Borbála Hermann, Csaba Szabó, Attila J Tóth-Heyn, Péter |
author_sort | Marics, Gábor |
collection | PubMed |
description | BACKGROUND: Continuous Glucose Monitoring (CGM) has become an increasingly investigated tool, especially with regards to monitoring of diabetic and critical care patients. The continuous glucose data allows the calculation of several glucose variability parameters, however, without specific application the interpretation of the results is time-consuming, utilizing extreme efforts. Our aim was to create an open access software [Glycemic Variability Analyzer Program (GVAP)], readily available to calculate the most common parameters of the glucose variability and to test its usability. METHODS: The GVAP was developed in MATLAB® 2010b environment. The calculated parameters were the following: average area above/below the target range (Avg. AUC-H/L); Percentage Spent Above/Below the Target Range (PATR/PBTR); Continuous Overall Net Glycemic Action (CONGA); Mean of Daily Differences (MODD); Mean Amplitude of Glycemic Excursions (MAGE). For verification purposes we selected 14 CGM curves of pediatric critical care patients. Medtronic® Guardian® Real-Time with Enlite® sensor was used. The reference values were obtained from Medtronic®(’)s own software for Avg. AUC-H/L and PATR/PBTR, from GlyCulator for MODD and CONGA, and using manual calculation for MAGE. RESULTS: The Pearson and Spearman correlation coefficients were above 0.99 for all parameters. The initial execution took 30 minutes, for further analysis with the Windows® Standalone Application approximately 1 minute was needed. CONCLUSIONS: The GVAP is a reliable open access program for analyzing different glycemic variability parameters, hence it could be a useful tool for the study of glycemic control among critically ill patients. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12938-015-0035-3) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4416329 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-44163292015-05-02 Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit Marics, Gábor Lendvai, Zsófia Lódi, Csaba Koncz, Levente Zakariás, Dávid Schuster, György Mikos, Borbála Hermann, Csaba Szabó, Attila J Tóth-Heyn, Péter Biomed Eng Online Research BACKGROUND: Continuous Glucose Monitoring (CGM) has become an increasingly investigated tool, especially with regards to monitoring of diabetic and critical care patients. The continuous glucose data allows the calculation of several glucose variability parameters, however, without specific application the interpretation of the results is time-consuming, utilizing extreme efforts. Our aim was to create an open access software [Glycemic Variability Analyzer Program (GVAP)], readily available to calculate the most common parameters of the glucose variability and to test its usability. METHODS: The GVAP was developed in MATLAB® 2010b environment. The calculated parameters were the following: average area above/below the target range (Avg. AUC-H/L); Percentage Spent Above/Below the Target Range (PATR/PBTR); Continuous Overall Net Glycemic Action (CONGA); Mean of Daily Differences (MODD); Mean Amplitude of Glycemic Excursions (MAGE). For verification purposes we selected 14 CGM curves of pediatric critical care patients. Medtronic® Guardian® Real-Time with Enlite® sensor was used. The reference values were obtained from Medtronic®(’)s own software for Avg. AUC-H/L and PATR/PBTR, from GlyCulator for MODD and CONGA, and using manual calculation for MAGE. RESULTS: The Pearson and Spearman correlation coefficients were above 0.99 for all parameters. The initial execution took 30 minutes, for further analysis with the Windows® Standalone Application approximately 1 minute was needed. CONCLUSIONS: The GVAP is a reliable open access program for analyzing different glycemic variability parameters, hence it could be a useful tool for the study of glycemic control among critically ill patients. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12938-015-0035-3) contains supplementary material, which is available to authorized users. BioMed Central 2015-04-24 /pmc/articles/PMC4416329/ /pubmed/25907677 http://dx.doi.org/10.1186/s12938-015-0035-3 Text en © Marics et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Marics, Gábor Lendvai, Zsófia Lódi, Csaba Koncz, Levente Zakariás, Dávid Schuster, György Mikos, Borbála Hermann, Csaba Szabó, Attila J Tóth-Heyn, Péter Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit |
title | Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit |
title_full | Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit |
title_fullStr | Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit |
title_full_unstemmed | Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit |
title_short | Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit |
title_sort | evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4416329/ https://www.ncbi.nlm.nih.gov/pubmed/25907677 http://dx.doi.org/10.1186/s12938-015-0035-3 |
work_keys_str_mv | AT maricsgabor evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT lendvaizsofia evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT lodicsaba evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT konczlevente evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT zakariasdavid evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT schustergyorgy evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT mikosborbala evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT hermanncsaba evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT szaboattilaj evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit AT tothheynpeter evaluationofanopenaccesssoftwareforcalculatingglucosevariabilityparametersofacontinuousglucosemonitoringsystemappliedatpediatricintensivecareunit |