Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code

BACKGROUND: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning s...

Descripción completa

Detalles Bibliográficos
Autores principales: Hadad, K., Zohrevand, M., Faghihi, R., Sedighi Pashaki, A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4417616/
https://www.ncbi.nlm.nih.gov/pubmed/25973408
_version_ 1782369389662699520
author Hadad, K.
Zohrevand, M.
Faghihi, R.
Sedighi Pashaki, A.
author_facet Hadad, K.
Zohrevand, M.
Faghihi, R.
Sedighi Pashaki, A.
author_sort Hadad, K.
collection PubMed
description BACKGROUND: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computations in a homogeneous phantom. Heterogeneous phantoms, especially patient-specific voxel phantoms can increase dosimetric accuracy. MATERIALS AND METHODS: In this study, using CT images taken from a patient and ctcreate-which is a part of the DOSXYZnrc computational code, patient-specific phantom was made. Dose distribution was plotted by DOSXYZnrc and compared with TPS one. Also, by extracting the voxels absorbed dose in treatment volume, dose-volume histograms (DVH) was plotted and compared with Oncentra™ TPS DVHs. RESULTS: The results from calculations were compared with data from Oncentra™ treatment planning system and it was observed that TPS calculation predicts lower dose in areas near the source, and higher dose in areas far from the source relative to MC code. Absorbed dose values in the voxels also showed that TPS reports D90 value is 40% higher than the Monte Carlo method. CONCLUSION: Today, most treatment planning systems use TG-43 protocol. This protocol may results in errors such as neglecting tissue heterogeneity, scattered radiation as well as applicator attenuation. Due to these errors, AAPM emphasized departing from TG-43 protocol and approaching new brachytherapy protocol TG-186 in which patient-specific phantom is used and heterogeneities are affected in dosimetry.
format Online
Article
Text
id pubmed-4417616
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-44176162015-05-13 Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code Hadad, K. Zohrevand, M. Faghihi, R. Sedighi Pashaki, A. J Biomed Phys Eng Original Article BACKGROUND: HDR brachytherapy is one of the commonest methods of nasopharyngeal cancer treatment. In this method, depending on how advanced one tumor is, 2 to 6 Gy dose as intracavitary brachytherapy is prescribed. Due to high dose rate and tumor location, accuracy evaluation of treatment planning system (TPS) is particularly important. Common methods used in TPS dosimetry are based on computations in a homogeneous phantom. Heterogeneous phantoms, especially patient-specific voxel phantoms can increase dosimetric accuracy. MATERIALS AND METHODS: In this study, using CT images taken from a patient and ctcreate-which is a part of the DOSXYZnrc computational code, patient-specific phantom was made. Dose distribution was plotted by DOSXYZnrc and compared with TPS one. Also, by extracting the voxels absorbed dose in treatment volume, dose-volume histograms (DVH) was plotted and compared with Oncentra™ TPS DVHs. RESULTS: The results from calculations were compared with data from Oncentra™ treatment planning system and it was observed that TPS calculation predicts lower dose in areas near the source, and higher dose in areas far from the source relative to MC code. Absorbed dose values in the voxels also showed that TPS reports D90 value is 40% higher than the Monte Carlo method. CONCLUSION: Today, most treatment planning systems use TG-43 protocol. This protocol may results in errors such as neglecting tissue heterogeneity, scattered radiation as well as applicator attenuation. Due to these errors, AAPM emphasized departing from TG-43 protocol and approaching new brachytherapy protocol TG-186 in which patient-specific phantom is used and heterogeneities are affected in dosimetry. Shiraz University of Medical Sciences 2015-03-04 /pmc/articles/PMC4417616/ /pubmed/25973408 Text en © 2015: Journal of Biomedical Physics and Engineering This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported License (http://creativecommons.org/licenses/by-nc/3.0/deed.en_US), which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hadad, K.
Zohrevand, M.
Faghihi, R.
Sedighi Pashaki, A.
Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
title Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
title_full Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
title_fullStr Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
title_full_unstemmed Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
title_short Accuracy Evaluation of Oncentra™ TPS in HDR Brachytherapy of Nasopharynx Cancer Using EGSnrc Monte Carlo Code
title_sort accuracy evaluation of oncentra™ tps in hdr brachytherapy of nasopharynx cancer using egsnrc monte carlo code
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4417616/
https://www.ncbi.nlm.nih.gov/pubmed/25973408
work_keys_str_mv AT hadadk accuracyevaluationofoncentratpsinhdrbrachytherapyofnasopharynxcancerusingegsnrcmontecarlocode
AT zohrevandm accuracyevaluationofoncentratpsinhdrbrachytherapyofnasopharynxcancerusingegsnrcmontecarlocode
AT faghihir accuracyevaluationofoncentratpsinhdrbrachytherapyofnasopharynxcancerusingegsnrcmontecarlocode
AT sedighipashakia accuracyevaluationofoncentratpsinhdrbrachytherapyofnasopharynxcancerusingegsnrcmontecarlocode