Cargando…

Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study

BACKGROUND: Obtaining high quality images in Single Photon Emission Tomography (SPECT) device  is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial...

Descripción completa

Detalles Bibliográficos
Autor principal: Banari Bahnamiri, Sh.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shiraz University of Medical Sciences 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4417619/
https://www.ncbi.nlm.nih.gov/pubmed/25973410
_version_ 1782369390346371072
author Banari Bahnamiri, Sh.
author_facet Banari Bahnamiri, Sh.
author_sort Banari Bahnamiri, Sh.
collection PubMed
description BACKGROUND: Obtaining high quality images in Single Photon Emission Tomography (SPECT) device  is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in SPECT imaging in nuclear medicine is the use of an appropriate collimator for a certain radiopharmaceutical feature in order to create the best image as it can be effective in the quantity of Full Width at Half Maximum (FWHM) which is the main parameter  in spatial resolution. METHOD: In this research, the simulation of the detector and collimator of SPECT imaging device, Model HD3 made by Philips Co. and the investigation of important factors on the collimator were carried out using MCNP-4c code. RESULTS: The results of the experimental measurments and simulation calculations revealed a relative difference of less than 5% leading to the confirmation of the accuracy of conducted simulation MCNP code calculation. CONCLUSION: This is the first essential step in the design and modelling of new collimators used for creating high quality images in nuclear medicine.
format Online
Article
Text
id pubmed-4417619
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Shiraz University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-44176192015-05-13 Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study Banari Bahnamiri, Sh. J Biomed Phys Eng Original Article BACKGROUND: Obtaining high quality images in Single Photon Emission Tomography (SPECT) device  is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in SPECT imaging in nuclear medicine is the use of an appropriate collimator for a certain radiopharmaceutical feature in order to create the best image as it can be effective in the quantity of Full Width at Half Maximum (FWHM) which is the main parameter  in spatial resolution. METHOD: In this research, the simulation of the detector and collimator of SPECT imaging device, Model HD3 made by Philips Co. and the investigation of important factors on the collimator were carried out using MCNP-4c code. RESULTS: The results of the experimental measurments and simulation calculations revealed a relative difference of less than 5% leading to the confirmation of the accuracy of conducted simulation MCNP code calculation. CONCLUSION: This is the first essential step in the design and modelling of new collimators used for creating high quality images in nuclear medicine. Shiraz University of Medical Sciences 2015-03-04 /pmc/articles/PMC4417619/ /pubmed/25973410 Text en © 2015: Journal of Biomedical Physics and Engineering This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported License (http://creativecommons.org/licenses/by-nc/3.0/deed.en_US), which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Banari Bahnamiri, Sh.
Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study
title Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study
title_full Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study
title_fullStr Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study
title_full_unstemmed Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study
title_short Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study
title_sort investigation of collimator influential parameter on spect image quality: a monte carlo study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4417619/
https://www.ncbi.nlm.nih.gov/pubmed/25973410
work_keys_str_mv AT banaribahnamirish investigationofcollimatorinfluentialparameteronspectimagequalityamontecarlostudy