Cargando…

Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency

BACKGROUND: Common variable immunodeficiency (CVID) is the most common clinically severe primary immunodeficiency and comprises a heterogeneous group of patients with recurrent severe bacterial infections due to the failure to produce IgG antibodies after exposure to infectious agents and immunizati...

Descripción completa

Detalles Bibliográficos
Autores principales: Fischer, Michael B., Wolfram, Wendelin, Binder, Christoph J., Böhmig, Georg A., Wahrmann, Markus, Eibl, Martha M., Wolf, Hermann M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422094/
https://www.ncbi.nlm.nih.gov/pubmed/25999949
http://dx.doi.org/10.3389/fimmu.2015.00211
_version_ 1782370006012526592
author Fischer, Michael B.
Wolfram, Wendelin
Binder, Christoph J.
Böhmig, Georg A.
Wahrmann, Markus
Eibl, Martha M.
Wolf, Hermann M.
author_facet Fischer, Michael B.
Wolfram, Wendelin
Binder, Christoph J.
Böhmig, Georg A.
Wahrmann, Markus
Eibl, Martha M.
Wolf, Hermann M.
author_sort Fischer, Michael B.
collection PubMed
description BACKGROUND: Common variable immunodeficiency (CVID) is the most common clinically severe primary immunodeficiency and comprises a heterogeneous group of patients with recurrent severe bacterial infections due to the failure to produce IgG antibodies after exposure to infectious agents and immunization. Diagnostic recommendations for antibody failure include assessment of isoagglutinins. We have readdressed this four decades old but still accepted recommendation with up to date methodology. METHODS: Anti-A/B IgM- and IgG-antibodies were measured by Diamed-ID Micro Typing, surface plasmon resonance (SPR) using the Biacore(®) device and flow cytometry. RESULTS: When Diamed-ID Micro Typing was used, CVID patients (n = 34) showed IgG- and IgM-isoagglutinins that were comparable to healthy volunteers (n = 28), while all XLA patients (n = 8) had none. Anti-A/B IgM-antibodies were present in more than 2/3 of the CVID patients and showed binding kinetics comparable to anti-A/B IgM-antibodies from healthy individuals. A correlation could be found in CVID patients between levels of anti-A/B IgM-antibodies and levels of serum IgM and PnP–IgM-antibodies. In contrast in CVID patients as a group ABO antibodies were significantly decreased when assessed by SPR, which correlated with levels of switched memory, non-switched memory and naïve B cells, but all CVID patients had low/undetectable anti-A/B IgG-antibodies. CONCLUSION: These results indicate that conventional isoagglutinin assessment and assessment of anti-A/B IgM antibodies are not suited for the diagnosis of impaired antibody production in CVID. Examination of anti-A/B IgG antibodies by SPR provides a useful method for the diagnosis of IgG antibody failure in all CVID patients studied, thus indicating an important additional rationale to start immunoglobulin replacement therapy early in these patients, before post-infectious sequelae develop.
format Online
Article
Text
id pubmed-4422094
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-44220942015-05-21 Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency Fischer, Michael B. Wolfram, Wendelin Binder, Christoph J. Böhmig, Georg A. Wahrmann, Markus Eibl, Martha M. Wolf, Hermann M. Front Immunol Immunology BACKGROUND: Common variable immunodeficiency (CVID) is the most common clinically severe primary immunodeficiency and comprises a heterogeneous group of patients with recurrent severe bacterial infections due to the failure to produce IgG antibodies after exposure to infectious agents and immunization. Diagnostic recommendations for antibody failure include assessment of isoagglutinins. We have readdressed this four decades old but still accepted recommendation with up to date methodology. METHODS: Anti-A/B IgM- and IgG-antibodies were measured by Diamed-ID Micro Typing, surface plasmon resonance (SPR) using the Biacore(®) device and flow cytometry. RESULTS: When Diamed-ID Micro Typing was used, CVID patients (n = 34) showed IgG- and IgM-isoagglutinins that were comparable to healthy volunteers (n = 28), while all XLA patients (n = 8) had none. Anti-A/B IgM-antibodies were present in more than 2/3 of the CVID patients and showed binding kinetics comparable to anti-A/B IgM-antibodies from healthy individuals. A correlation could be found in CVID patients between levels of anti-A/B IgM-antibodies and levels of serum IgM and PnP–IgM-antibodies. In contrast in CVID patients as a group ABO antibodies were significantly decreased when assessed by SPR, which correlated with levels of switched memory, non-switched memory and naïve B cells, but all CVID patients had low/undetectable anti-A/B IgG-antibodies. CONCLUSION: These results indicate that conventional isoagglutinin assessment and assessment of anti-A/B IgM antibodies are not suited for the diagnosis of impaired antibody production in CVID. Examination of anti-A/B IgG antibodies by SPR provides a useful method for the diagnosis of IgG antibody failure in all CVID patients studied, thus indicating an important additional rationale to start immunoglobulin replacement therapy early in these patients, before post-infectious sequelae develop. Frontiers Media S.A. 2015-05-06 /pmc/articles/PMC4422094/ /pubmed/25999949 http://dx.doi.org/10.3389/fimmu.2015.00211 Text en Copyright © 2015 Fischer, Wolfram, Binder, Böhmig, Wahrmann, Eibl and Wolf. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Immunology
Fischer, Michael B.
Wolfram, Wendelin
Binder, Christoph J.
Böhmig, Georg A.
Wahrmann, Markus
Eibl, Martha M.
Wolf, Hermann M.
Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency
title Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency
title_full Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency
title_fullStr Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency
title_full_unstemmed Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency
title_short Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency
title_sort surface plasmon resonance analysis shows an igg-isotype-specific defect in abo blood group antibody formation in patients with common variable immunodeficiency
topic Immunology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422094/
https://www.ncbi.nlm.nih.gov/pubmed/25999949
http://dx.doi.org/10.3389/fimmu.2015.00211
work_keys_str_mv AT fischermichaelb surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency
AT wolframwendelin surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency
AT binderchristophj surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency
AT bohmiggeorga surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency
AT wahrmannmarkus surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency
AT eiblmartham surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency
AT wolfhermannm surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency