Cargando…
Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency
BACKGROUND: Common variable immunodeficiency (CVID) is the most common clinically severe primary immunodeficiency and comprises a heterogeneous group of patients with recurrent severe bacterial infections due to the failure to produce IgG antibodies after exposure to infectious agents and immunizati...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422094/ https://www.ncbi.nlm.nih.gov/pubmed/25999949 http://dx.doi.org/10.3389/fimmu.2015.00211 |
_version_ | 1782370006012526592 |
---|---|
author | Fischer, Michael B. Wolfram, Wendelin Binder, Christoph J. Böhmig, Georg A. Wahrmann, Markus Eibl, Martha M. Wolf, Hermann M. |
author_facet | Fischer, Michael B. Wolfram, Wendelin Binder, Christoph J. Böhmig, Georg A. Wahrmann, Markus Eibl, Martha M. Wolf, Hermann M. |
author_sort | Fischer, Michael B. |
collection | PubMed |
description | BACKGROUND: Common variable immunodeficiency (CVID) is the most common clinically severe primary immunodeficiency and comprises a heterogeneous group of patients with recurrent severe bacterial infections due to the failure to produce IgG antibodies after exposure to infectious agents and immunization. Diagnostic recommendations for antibody failure include assessment of isoagglutinins. We have readdressed this four decades old but still accepted recommendation with up to date methodology. METHODS: Anti-A/B IgM- and IgG-antibodies were measured by Diamed-ID Micro Typing, surface plasmon resonance (SPR) using the Biacore(®) device and flow cytometry. RESULTS: When Diamed-ID Micro Typing was used, CVID patients (n = 34) showed IgG- and IgM-isoagglutinins that were comparable to healthy volunteers (n = 28), while all XLA patients (n = 8) had none. Anti-A/B IgM-antibodies were present in more than 2/3 of the CVID patients and showed binding kinetics comparable to anti-A/B IgM-antibodies from healthy individuals. A correlation could be found in CVID patients between levels of anti-A/B IgM-antibodies and levels of serum IgM and PnP–IgM-antibodies. In contrast in CVID patients as a group ABO antibodies were significantly decreased when assessed by SPR, which correlated with levels of switched memory, non-switched memory and naïve B cells, but all CVID patients had low/undetectable anti-A/B IgG-antibodies. CONCLUSION: These results indicate that conventional isoagglutinin assessment and assessment of anti-A/B IgM antibodies are not suited for the diagnosis of impaired antibody production in CVID. Examination of anti-A/B IgG antibodies by SPR provides a useful method for the diagnosis of IgG antibody failure in all CVID patients studied, thus indicating an important additional rationale to start immunoglobulin replacement therapy early in these patients, before post-infectious sequelae develop. |
format | Online Article Text |
id | pubmed-4422094 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-44220942015-05-21 Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency Fischer, Michael B. Wolfram, Wendelin Binder, Christoph J. Böhmig, Georg A. Wahrmann, Markus Eibl, Martha M. Wolf, Hermann M. Front Immunol Immunology BACKGROUND: Common variable immunodeficiency (CVID) is the most common clinically severe primary immunodeficiency and comprises a heterogeneous group of patients with recurrent severe bacterial infections due to the failure to produce IgG antibodies after exposure to infectious agents and immunization. Diagnostic recommendations for antibody failure include assessment of isoagglutinins. We have readdressed this four decades old but still accepted recommendation with up to date methodology. METHODS: Anti-A/B IgM- and IgG-antibodies were measured by Diamed-ID Micro Typing, surface plasmon resonance (SPR) using the Biacore(®) device and flow cytometry. RESULTS: When Diamed-ID Micro Typing was used, CVID patients (n = 34) showed IgG- and IgM-isoagglutinins that were comparable to healthy volunteers (n = 28), while all XLA patients (n = 8) had none. Anti-A/B IgM-antibodies were present in more than 2/3 of the CVID patients and showed binding kinetics comparable to anti-A/B IgM-antibodies from healthy individuals. A correlation could be found in CVID patients between levels of anti-A/B IgM-antibodies and levels of serum IgM and PnP–IgM-antibodies. In contrast in CVID patients as a group ABO antibodies were significantly decreased when assessed by SPR, which correlated with levels of switched memory, non-switched memory and naïve B cells, but all CVID patients had low/undetectable anti-A/B IgG-antibodies. CONCLUSION: These results indicate that conventional isoagglutinin assessment and assessment of anti-A/B IgM antibodies are not suited for the diagnosis of impaired antibody production in CVID. Examination of anti-A/B IgG antibodies by SPR provides a useful method for the diagnosis of IgG antibody failure in all CVID patients studied, thus indicating an important additional rationale to start immunoglobulin replacement therapy early in these patients, before post-infectious sequelae develop. Frontiers Media S.A. 2015-05-06 /pmc/articles/PMC4422094/ /pubmed/25999949 http://dx.doi.org/10.3389/fimmu.2015.00211 Text en Copyright © 2015 Fischer, Wolfram, Binder, Böhmig, Wahrmann, Eibl and Wolf. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Immunology Fischer, Michael B. Wolfram, Wendelin Binder, Christoph J. Böhmig, Georg A. Wahrmann, Markus Eibl, Martha M. Wolf, Hermann M. Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency |
title | Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency |
title_full | Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency |
title_fullStr | Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency |
title_full_unstemmed | Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency |
title_short | Surface Plasmon Resonance Analysis Shows an IgG-Isotype-Specific Defect in ABO Blood Group Antibody Formation in Patients with Common Variable Immunodeficiency |
title_sort | surface plasmon resonance analysis shows an igg-isotype-specific defect in abo blood group antibody formation in patients with common variable immunodeficiency |
topic | Immunology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422094/ https://www.ncbi.nlm.nih.gov/pubmed/25999949 http://dx.doi.org/10.3389/fimmu.2015.00211 |
work_keys_str_mv | AT fischermichaelb surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency AT wolframwendelin surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency AT binderchristophj surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency AT bohmiggeorga surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency AT wahrmannmarkus surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency AT eiblmartham surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency AT wolfhermannm surfaceplasmonresonanceanalysisshowsaniggisotypespecificdefectinabobloodgroupantibodyformationinpatientswithcommonvariableimmunodeficiency |