Cargando…

Noninvasive monitoring of mouse renal allograft rejection using micro-CT

PURPOSE: Acute renal graft rejection can only be definitively diagnosed by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Micro-CT is widely used in preclinical studies of small animals. Here, we propose micro-CT could noninvasively monitor and evaluate renal locat...

Descripción completa

Detalles Bibliográficos
Autores principales: Hou, Jiangang, Fujino, Masayuki, Cai, Songjie, Ding, Qiang, Li, Xiao-Kang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Surgical Society 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422881/
https://www.ncbi.nlm.nih.gov/pubmed/25960991
http://dx.doi.org/10.4174/astr.2015.88.5.276
_version_ 1782370124723912704
author Hou, Jiangang
Fujino, Masayuki
Cai, Songjie
Ding, Qiang
Li, Xiao-Kang
author_facet Hou, Jiangang
Fujino, Masayuki
Cai, Songjie
Ding, Qiang
Li, Xiao-Kang
author_sort Hou, Jiangang
collection PubMed
description PURPOSE: Acute renal graft rejection can only be definitively diagnosed by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Micro-CT is widely used in preclinical studies of small animals. Here, we propose micro-CT could noninvasively monitor and evaluate renal location and function in a mouse kidney transplant model. METHODS: Orthotopic kidney transplantation was performed in a BALB/c -to- C57BL/6j or C57BL/6j-to- C57BL/6j mouse model. After optimizing imaging techniques, five mice were imaged with micro-CT and the findings were verified histologically. RESULTS: Micro-CT can monitor and evaluate renal location and function after orthotopic kidney transplantation. There were no mice deaths while renal transplants were failure. CONCLUSION: We propose that graft micro-CT imaging is a new option that is noninvasive and specific, and can aid in early detection and follow-up of acute renal rejection. This method is potentially useful to improve posttransplant rejection monitoring.
format Online
Article
Text
id pubmed-4422881
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Surgical Society
record_format MEDLINE/PubMed
spelling pubmed-44228812015-05-08 Noninvasive monitoring of mouse renal allograft rejection using micro-CT Hou, Jiangang Fujino, Masayuki Cai, Songjie Ding, Qiang Li, Xiao-Kang Ann Surg Treat Res Original Article PURPOSE: Acute renal graft rejection can only be definitively diagnosed by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Micro-CT is widely used in preclinical studies of small animals. Here, we propose micro-CT could noninvasively monitor and evaluate renal location and function in a mouse kidney transplant model. METHODS: Orthotopic kidney transplantation was performed in a BALB/c -to- C57BL/6j or C57BL/6j-to- C57BL/6j mouse model. After optimizing imaging techniques, five mice were imaged with micro-CT and the findings were verified histologically. RESULTS: Micro-CT can monitor and evaluate renal location and function after orthotopic kidney transplantation. There were no mice deaths while renal transplants were failure. CONCLUSION: We propose that graft micro-CT imaging is a new option that is noninvasive and specific, and can aid in early detection and follow-up of acute renal rejection. This method is potentially useful to improve posttransplant rejection monitoring. The Korean Surgical Society 2015-05 2015-04-30 /pmc/articles/PMC4422881/ /pubmed/25960991 http://dx.doi.org/10.4174/astr.2015.88.5.276 Text en Copyright © 2015, the Korean Surgical Society http://creativecommons.org/licenses/by-nc/3.0/ Annals of Surgical Treatment and Research is an Open Access Journal. All articles are distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hou, Jiangang
Fujino, Masayuki
Cai, Songjie
Ding, Qiang
Li, Xiao-Kang
Noninvasive monitoring of mouse renal allograft rejection using micro-CT
title Noninvasive monitoring of mouse renal allograft rejection using micro-CT
title_full Noninvasive monitoring of mouse renal allograft rejection using micro-CT
title_fullStr Noninvasive monitoring of mouse renal allograft rejection using micro-CT
title_full_unstemmed Noninvasive monitoring of mouse renal allograft rejection using micro-CT
title_short Noninvasive monitoring of mouse renal allograft rejection using micro-CT
title_sort noninvasive monitoring of mouse renal allograft rejection using micro-ct
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422881/
https://www.ncbi.nlm.nih.gov/pubmed/25960991
http://dx.doi.org/10.4174/astr.2015.88.5.276
work_keys_str_mv AT houjiangang noninvasivemonitoringofmouserenalallograftrejectionusingmicroct
AT fujinomasayuki noninvasivemonitoringofmouserenalallograftrejectionusingmicroct
AT caisongjie noninvasivemonitoringofmouserenalallograftrejectionusingmicroct
AT dingqiang noninvasivemonitoringofmouserenalallograftrejectionusingmicroct
AT lixiaokang noninvasivemonitoringofmouserenalallograftrejectionusingmicroct