Cargando…
Noninvasive monitoring of mouse renal allograft rejection using micro-CT
PURPOSE: Acute renal graft rejection can only be definitively diagnosed by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Micro-CT is widely used in preclinical studies of small animals. Here, we propose micro-CT could noninvasively monitor and evaluate renal locat...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Surgical Society
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422881/ https://www.ncbi.nlm.nih.gov/pubmed/25960991 http://dx.doi.org/10.4174/astr.2015.88.5.276 |
_version_ | 1782370124723912704 |
---|---|
author | Hou, Jiangang Fujino, Masayuki Cai, Songjie Ding, Qiang Li, Xiao-Kang |
author_facet | Hou, Jiangang Fujino, Masayuki Cai, Songjie Ding, Qiang Li, Xiao-Kang |
author_sort | Hou, Jiangang |
collection | PubMed |
description | PURPOSE: Acute renal graft rejection can only be definitively diagnosed by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Micro-CT is widely used in preclinical studies of small animals. Here, we propose micro-CT could noninvasively monitor and evaluate renal location and function in a mouse kidney transplant model. METHODS: Orthotopic kidney transplantation was performed in a BALB/c -to- C57BL/6j or C57BL/6j-to- C57BL/6j mouse model. After optimizing imaging techniques, five mice were imaged with micro-CT and the findings were verified histologically. RESULTS: Micro-CT can monitor and evaluate renal location and function after orthotopic kidney transplantation. There were no mice deaths while renal transplants were failure. CONCLUSION: We propose that graft micro-CT imaging is a new option that is noninvasive and specific, and can aid in early detection and follow-up of acute renal rejection. This method is potentially useful to improve posttransplant rejection monitoring. |
format | Online Article Text |
id | pubmed-4422881 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Surgical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-44228812015-05-08 Noninvasive monitoring of mouse renal allograft rejection using micro-CT Hou, Jiangang Fujino, Masayuki Cai, Songjie Ding, Qiang Li, Xiao-Kang Ann Surg Treat Res Original Article PURPOSE: Acute renal graft rejection can only be definitively diagnosed by renal biopsy. However, biopsies carry a risk of renal transplant injury and loss. Micro-CT is widely used in preclinical studies of small animals. Here, we propose micro-CT could noninvasively monitor and evaluate renal location and function in a mouse kidney transplant model. METHODS: Orthotopic kidney transplantation was performed in a BALB/c -to- C57BL/6j or C57BL/6j-to- C57BL/6j mouse model. After optimizing imaging techniques, five mice were imaged with micro-CT and the findings were verified histologically. RESULTS: Micro-CT can monitor and evaluate renal location and function after orthotopic kidney transplantation. There were no mice deaths while renal transplants were failure. CONCLUSION: We propose that graft micro-CT imaging is a new option that is noninvasive and specific, and can aid in early detection and follow-up of acute renal rejection. This method is potentially useful to improve posttransplant rejection monitoring. The Korean Surgical Society 2015-05 2015-04-30 /pmc/articles/PMC4422881/ /pubmed/25960991 http://dx.doi.org/10.4174/astr.2015.88.5.276 Text en Copyright © 2015, the Korean Surgical Society http://creativecommons.org/licenses/by-nc/3.0/ Annals of Surgical Treatment and Research is an Open Access Journal. All articles are distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Hou, Jiangang Fujino, Masayuki Cai, Songjie Ding, Qiang Li, Xiao-Kang Noninvasive monitoring of mouse renal allograft rejection using micro-CT |
title | Noninvasive monitoring of mouse renal allograft rejection using micro-CT |
title_full | Noninvasive monitoring of mouse renal allograft rejection using micro-CT |
title_fullStr | Noninvasive monitoring of mouse renal allograft rejection using micro-CT |
title_full_unstemmed | Noninvasive monitoring of mouse renal allograft rejection using micro-CT |
title_short | Noninvasive monitoring of mouse renal allograft rejection using micro-CT |
title_sort | noninvasive monitoring of mouse renal allograft rejection using micro-ct |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4422881/ https://www.ncbi.nlm.nih.gov/pubmed/25960991 http://dx.doi.org/10.4174/astr.2015.88.5.276 |
work_keys_str_mv | AT houjiangang noninvasivemonitoringofmouserenalallograftrejectionusingmicroct AT fujinomasayuki noninvasivemonitoringofmouserenalallograftrejectionusingmicroct AT caisongjie noninvasivemonitoringofmouserenalallograftrejectionusingmicroct AT dingqiang noninvasivemonitoringofmouserenalallograftrejectionusingmicroct AT lixiaokang noninvasivemonitoringofmouserenalallograftrejectionusingmicroct |