Cargando…
A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection
Background and study aims: Propofol administration via a target-controlled infusion system with bispectral index monitoring (BIS/TCI system) is expected to prevent complications from sedation during complex and long endoscopic procedures. We evaluated the feasibility of setting the BIS/TCI system fo...
Autores principales: | , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
© Georg Thieme Verlag KG
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4423246/ https://www.ncbi.nlm.nih.gov/pubmed/26134767 http://dx.doi.org/10.1055/s-0034-1377519 |
_version_ | 1782370178358575104 |
---|---|
author | Imagawa, Atsushi Hata, Hidenori Nakatsu, Morihito Matsumi, Akihiro Ueta, Eijiro Suto, Kozue Terasawa, Hiroyuki Sakae, Hiroyuki Takeuchi, Keiko Fujihara, Manabu Endo, Hitomi Yasuhara, Hisae Ishihara, Shinichi Kanzaki, Hiromitsu Jinno, Hideki Kamada, Hidenori Kaji, Eisuke Moriya, Akio Ando, Masaharu |
author_facet | Imagawa, Atsushi Hata, Hidenori Nakatsu, Morihito Matsumi, Akihiro Ueta, Eijiro Suto, Kozue Terasawa, Hiroyuki Sakae, Hiroyuki Takeuchi, Keiko Fujihara, Manabu Endo, Hitomi Yasuhara, Hisae Ishihara, Shinichi Kanzaki, Hiromitsu Jinno, Hideki Kamada, Hidenori Kaji, Eisuke Moriya, Akio Ando, Masaharu |
author_sort | Imagawa, Atsushi |
collection | PubMed |
description | Background and study aims: Propofol administration via a target-controlled infusion system with bispectral index monitoring (BIS/TCI system) is expected to prevent complications from sedation during complex and long endoscopic procedures. We evaluated the feasibility of setting the BIS/TCI system for non-anesthesiologist administration of propofol (NAAP) during endoscopic submucosal dissection (ESD). Patients and methods: From May 2009 to February 2013, 250 patients with esophagogastric neoplasms were treated with ESD using the BIS/TCI system with NAAP. In the TCI system, the initial target blood concentration of propofol was set at 1.2 μg/mL. The titration speed of propofol was adjusted according to the BIS score and the movement of the patient. The BIS target level ranged from moderate to deep sedation, at which a stable BIS score between 60 and 80 was obtained. Results: In 80.4 % of patients, it was possible to maintain stable sedation with a blood concentration of propofol of less than 1.6 µg/mL using TCI throughout the ESD procedure. The default setting for ideal blood concentration of propofol was 1.2 μg/mL, because the medians of the lower and upper bounds of blood concentration were 1.2 μg/mL (range 0.6 – 1.8 μg/mL) and 1.4 μg/mL (range 1.0 – 3.8 μg/mL), respectively. Although hypotension occurred in 27 patients (10.8 %), oxygen desaturation occurred in only nine patients (3.6 %), and severe desaturation in only two patients (0.8 %). Conclusions: Using our settings, it is possible for a non-anesthesiologist to maintain stable sedation during a lengthy endoscopic procedure through propofol sedation with a BIS/TCI system. |
format | Online Article Text |
id | pubmed-4423246 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | © Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-44232462015-06-23 A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection Imagawa, Atsushi Hata, Hidenori Nakatsu, Morihito Matsumi, Akihiro Ueta, Eijiro Suto, Kozue Terasawa, Hiroyuki Sakae, Hiroyuki Takeuchi, Keiko Fujihara, Manabu Endo, Hitomi Yasuhara, Hisae Ishihara, Shinichi Kanzaki, Hiromitsu Jinno, Hideki Kamada, Hidenori Kaji, Eisuke Moriya, Akio Ando, Masaharu Endosc Int Open Article Background and study aims: Propofol administration via a target-controlled infusion system with bispectral index monitoring (BIS/TCI system) is expected to prevent complications from sedation during complex and long endoscopic procedures. We evaluated the feasibility of setting the BIS/TCI system for non-anesthesiologist administration of propofol (NAAP) during endoscopic submucosal dissection (ESD). Patients and methods: From May 2009 to February 2013, 250 patients with esophagogastric neoplasms were treated with ESD using the BIS/TCI system with NAAP. In the TCI system, the initial target blood concentration of propofol was set at 1.2 μg/mL. The titration speed of propofol was adjusted according to the BIS score and the movement of the patient. The BIS target level ranged from moderate to deep sedation, at which a stable BIS score between 60 and 80 was obtained. Results: In 80.4 % of patients, it was possible to maintain stable sedation with a blood concentration of propofol of less than 1.6 µg/mL using TCI throughout the ESD procedure. The default setting for ideal blood concentration of propofol was 1.2 μg/mL, because the medians of the lower and upper bounds of blood concentration were 1.2 μg/mL (range 0.6 – 1.8 μg/mL) and 1.4 μg/mL (range 1.0 – 3.8 μg/mL), respectively. Although hypotension occurred in 27 patients (10.8 %), oxygen desaturation occurred in only nine patients (3.6 %), and severe desaturation in only two patients (0.8 %). Conclusions: Using our settings, it is possible for a non-anesthesiologist to maintain stable sedation during a lengthy endoscopic procedure through propofol sedation with a BIS/TCI system. © Georg Thieme Verlag KG 2015-02 2014-11-17 /pmc/articles/PMC4423246/ /pubmed/26134767 http://dx.doi.org/10.1055/s-0034-1377519 Text en © Thieme Medical Publishers |
spellingShingle | Article Imagawa, Atsushi Hata, Hidenori Nakatsu, Morihito Matsumi, Akihiro Ueta, Eijiro Suto, Kozue Terasawa, Hiroyuki Sakae, Hiroyuki Takeuchi, Keiko Fujihara, Manabu Endo, Hitomi Yasuhara, Hisae Ishihara, Shinichi Kanzaki, Hiromitsu Jinno, Hideki Kamada, Hidenori Kaji, Eisuke Moriya, Akio Ando, Masaharu A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection |
title | A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection |
title_full | A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection |
title_fullStr | A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection |
title_full_unstemmed | A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection |
title_short | A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection |
title_sort | target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4423246/ https://www.ncbi.nlm.nih.gov/pubmed/26134767 http://dx.doi.org/10.1055/s-0034-1377519 |
work_keys_str_mv | AT imagawaatsushi atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT hatahidenori atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT nakatsumorihito atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT matsumiakihiro atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT uetaeijiro atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT sutokozue atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT terasawahiroyuki atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT sakaehiroyuki atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT takeuchikeiko atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT fujiharamanabu atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT endohitomi atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT yasuharahisae atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT ishiharashinichi atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT kanzakihiromitsu atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT jinnohideki atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT kamadahidenori atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT kajieisuke atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT moriyaakio atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT andomasaharu atargetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT imagawaatsushi targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT hatahidenori targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT nakatsumorihito targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT matsumiakihiro targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT uetaeijiro targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT sutokozue targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT terasawahiroyuki targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT sakaehiroyuki targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT takeuchikeiko targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT fujiharamanabu targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT endohitomi targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT yasuharahisae targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT ishiharashinichi targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT kanzakihiromitsu targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT jinnohideki targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT kamadahidenori targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT kajieisuke targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT moriyaakio targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection AT andomasaharu targetcontrolledinfusionsystemwithbispectralindexmonitoringofpropofolsedationduringendoscopicsubmucosaldissection |