Cargando…

Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler

A culture-based colony counting method is the most widely used analytical technique for monitoring bioaerosols in both indoor and outdoor environments. However, this method requires several days for colony formation. In this study, our goal was fast monitoring (Sampling: 3 min, Detection: < 1 min...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Ji-Woon, Park, Chul Woo, Lee, Sung Hwa, Hwang, Jungho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4423956/
https://www.ncbi.nlm.nih.gov/pubmed/25950929
http://dx.doi.org/10.1371/journal.pone.0125251
_version_ 1782370284074958848
author Park, Ji-Woon
Park, Chul Woo
Lee, Sung Hwa
Hwang, Jungho
author_facet Park, Ji-Woon
Park, Chul Woo
Lee, Sung Hwa
Hwang, Jungho
author_sort Park, Ji-Woon
collection PubMed
description A culture-based colony counting method is the most widely used analytical technique for monitoring bioaerosols in both indoor and outdoor environments. However, this method requires several days for colony formation. In this study, our goal was fast monitoring (Sampling: 3 min, Detection: < 1 min) of indoor bioaerosol concentrations with ATP bioluminescence assay using a bioaerosol sampler. For this purpose, a novel hand-held electrostatic rod-type sampler (110 mm wide, 115 mm long, and 200 mm tall) was developed and used with a commercial luminometer, which employs the Adenosine triphosphate (ATP) bioluminescence method. The sampler consisted of a wire-rod type charger and a cylindrical collector, and was operated with an applied voltage of 4.5 kV and a sampling flow rate of 150.7 lpm. Its performance was tested using Staphylococcus epidermidis which was aerosolized with an atomizer. Bioaerosol concentrations were measured using ATP bioluminescence method with our sampler and compared with the culture-based method using Andersen cascade impactor under controlled laboratory conditions. Indoor bioaerosol concentrations were also measured using both methods in various indoor environments. A linear correlation was obtained between both methods in lab-tests and field-tests. Our proposed sampler with ATP bioluminescence method may be effective for fast monitoring of indoor bioaerosol concentrations.
format Online
Article
Text
id pubmed-4423956
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44239562015-05-13 Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler Park, Ji-Woon Park, Chul Woo Lee, Sung Hwa Hwang, Jungho PLoS One Research Article A culture-based colony counting method is the most widely used analytical technique for monitoring bioaerosols in both indoor and outdoor environments. However, this method requires several days for colony formation. In this study, our goal was fast monitoring (Sampling: 3 min, Detection: < 1 min) of indoor bioaerosol concentrations with ATP bioluminescence assay using a bioaerosol sampler. For this purpose, a novel hand-held electrostatic rod-type sampler (110 mm wide, 115 mm long, and 200 mm tall) was developed and used with a commercial luminometer, which employs the Adenosine triphosphate (ATP) bioluminescence method. The sampler consisted of a wire-rod type charger and a cylindrical collector, and was operated with an applied voltage of 4.5 kV and a sampling flow rate of 150.7 lpm. Its performance was tested using Staphylococcus epidermidis which was aerosolized with an atomizer. Bioaerosol concentrations were measured using ATP bioluminescence method with our sampler and compared with the culture-based method using Andersen cascade impactor under controlled laboratory conditions. Indoor bioaerosol concentrations were also measured using both methods in various indoor environments. A linear correlation was obtained between both methods in lab-tests and field-tests. Our proposed sampler with ATP bioluminescence method may be effective for fast monitoring of indoor bioaerosol concentrations. Public Library of Science 2015-05-07 /pmc/articles/PMC4423956/ /pubmed/25950929 http://dx.doi.org/10.1371/journal.pone.0125251 Text en © 2015 Park et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Park, Ji-Woon
Park, Chul Woo
Lee, Sung Hwa
Hwang, Jungho
Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler
title Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler
title_full Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler
title_fullStr Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler
title_full_unstemmed Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler
title_short Fast Monitoring of Indoor Bioaerosol Concentrations with ATP Bioluminescence Assay Using an Electrostatic Rod-Type Sampler
title_sort fast monitoring of indoor bioaerosol concentrations with atp bioluminescence assay using an electrostatic rod-type sampler
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4423956/
https://www.ncbi.nlm.nih.gov/pubmed/25950929
http://dx.doi.org/10.1371/journal.pone.0125251
work_keys_str_mv AT parkjiwoon fastmonitoringofindoorbioaerosolconcentrationswithatpbioluminescenceassayusinganelectrostaticrodtypesampler
AT parkchulwoo fastmonitoringofindoorbioaerosolconcentrationswithatpbioluminescenceassayusinganelectrostaticrodtypesampler
AT leesunghwa fastmonitoringofindoorbioaerosolconcentrationswithatpbioluminescenceassayusinganelectrostaticrodtypesampler
AT hwangjungho fastmonitoringofindoorbioaerosolconcentrationswithatpbioluminescenceassayusinganelectrostaticrodtypesampler