Cargando…

A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer

The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy™ (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our center between Jan...

Descripción completa

Detalles Bibliográficos
Autores principales: Chitapanarux, Imjai, Tharavichitkul, Ekkasit, Nobnop, Wannapa, Wanwilairat, Somsak, Vongtama, Roy, Traisathit, Patrinee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4426928/
https://www.ncbi.nlm.nih.gov/pubmed/25720771
http://dx.doi.org/10.1093/jrr/rrv004
_version_ 1782370652799369216
author Chitapanarux, Imjai
Tharavichitkul, Ekkasit
Nobnop, Wannapa
Wanwilairat, Somsak
Vongtama, Roy
Traisathit, Patrinee
author_facet Chitapanarux, Imjai
Tharavichitkul, Ekkasit
Nobnop, Wannapa
Wanwilairat, Somsak
Vongtama, Roy
Traisathit, Patrinee
author_sort Chitapanarux, Imjai
collection PubMed
description The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy™ (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our center between January 2011 and January 2014. SaS-IMRT and HT treatment plans were generated for each patient. The dosimetric values for target coverage and organ-at-risk (OAR) sparing were compared according to the criteria of the International Commission on Radiation Units and Measurements 83 (ICRU 83) guidelines. Differences in beam-on time (BOT) were also compared. All the PTV dosimetric parameters (D5%, D50% and D95%) for the HT plan were (statistically significantly) of better quality than those for the SaS-IMRT plan (P-value < 0.001 in all respects). HT was also significantly more accurate than SaS-IMRT with respect to the D98% and Dmean of the CTV (P-values of 0.008 and <0.001, respectively). The median Conformity Index (CI) did not differ between the two plans (P-value = 0.057). However, the Uniformity Index for HT was significantly better than that for SaS-IMRT (P-value < 0.001). The median of D50% for the bladder, rectum and small bowel were significantly lower in HT planning than SaS-IMRT (P-value < 0.001). For D2%, we found that HT provided better sparing to the rectum and bladder (P-value < 0.001). However, the median of D2% for the small bowel was comparable for both plans. The median of Dmax of the head of the left femur was significantly lower in the HT plan, but this did not apply for the head of the right femur. BOT for HT was significantly shorter than for SaS-IMRT (P-value < 0.001). HT provided highly accurate plans, with more homogeneous PTV coverage and superior sparing of OARs than SaS-IMRT. In addition, HT enabled a shorter delivery time than SaS-IMRT.
format Online
Article
Text
id pubmed-4426928
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-44269282015-05-15 A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer Chitapanarux, Imjai Tharavichitkul, Ekkasit Nobnop, Wannapa Wanwilairat, Somsak Vongtama, Roy Traisathit, Patrinee J Radiat Res Oncology The aim of this study was to compare the dosimetric parameters of whole-pelvis radiotherapy (WPRT) for cervical cancer between step-and-shoot IMRT (SaS-IMRT) and Helical Tomotherapy™ (HT). Retrospective analysis was performed on 20 cervical cancer patients who received WPRT in our center between January 2011 and January 2014. SaS-IMRT and HT treatment plans were generated for each patient. The dosimetric values for target coverage and organ-at-risk (OAR) sparing were compared according to the criteria of the International Commission on Radiation Units and Measurements 83 (ICRU 83) guidelines. Differences in beam-on time (BOT) were also compared. All the PTV dosimetric parameters (D5%, D50% and D95%) for the HT plan were (statistically significantly) of better quality than those for the SaS-IMRT plan (P-value < 0.001 in all respects). HT was also significantly more accurate than SaS-IMRT with respect to the D98% and Dmean of the CTV (P-values of 0.008 and <0.001, respectively). The median Conformity Index (CI) did not differ between the two plans (P-value = 0.057). However, the Uniformity Index for HT was significantly better than that for SaS-IMRT (P-value < 0.001). The median of D50% for the bladder, rectum and small bowel were significantly lower in HT planning than SaS-IMRT (P-value < 0.001). For D2%, we found that HT provided better sparing to the rectum and bladder (P-value < 0.001). However, the median of D2% for the small bowel was comparable for both plans. The median of Dmax of the head of the left femur was significantly lower in the HT plan, but this did not apply for the head of the right femur. BOT for HT was significantly shorter than for SaS-IMRT (P-value < 0.001). HT provided highly accurate plans, with more homogeneous PTV coverage and superior sparing of OARs than SaS-IMRT. In addition, HT enabled a shorter delivery time than SaS-IMRT. Oxford University Press 2015-05 2015-02-26 /pmc/articles/PMC4426928/ /pubmed/25720771 http://dx.doi.org/10.1093/jrr/rrv004 Text en © The Author 2015. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Oncology
Chitapanarux, Imjai
Tharavichitkul, Ekkasit
Nobnop, Wannapa
Wanwilairat, Somsak
Vongtama, Roy
Traisathit, Patrinee
A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_full A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_fullStr A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_full_unstemmed A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_short A comparative planning study of step-and-shoot IMRT versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
title_sort comparative planning study of step-and-shoot imrt versus helical tomotherapy for whole-pelvis irradiation in cervical cancer
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4426928/
https://www.ncbi.nlm.nih.gov/pubmed/25720771
http://dx.doi.org/10.1093/jrr/rrv004
work_keys_str_mv AT chitapanaruximjai acomparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT tharavichitkulekkasit acomparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT nobnopwannapa acomparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT wanwilairatsomsak acomparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT vongtamaroy acomparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT traisathitpatrinee acomparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT chitapanaruximjai comparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT tharavichitkulekkasit comparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT nobnopwannapa comparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT wanwilairatsomsak comparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT vongtamaroy comparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer
AT traisathitpatrinee comparativeplanningstudyofstepandshootimrtversushelicaltomotherapyforwholepelvisirradiationincervicalcancer