Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry
A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data....
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4430627/ https://www.ncbi.nlm.nih.gov/pubmed/26064874 http://dx.doi.org/10.1155/2015/103137 |
_version_ | 1782371206624706560 |
---|---|
author | Gabler, Carolin Zietz, Carmen Bieck, Richard Göhler, Rebecca Lindner, Tobias Haenle, Maximilian Finke, Birgit Meichsner, Jürgen Testrich, Holger Nowottnick, Mathias Frerich, Bernhard Bader, Rainer |
author_facet | Gabler, Carolin Zietz, Carmen Bieck, Richard Göhler, Rebecca Lindner, Tobias Haenle, Maximilian Finke, Birgit Meichsner, Jürgen Testrich, Holger Nowottnick, Mathias Frerich, Bernhard Bader, Rainer |
author_sort | Gabler, Carolin |
collection | PubMed |
description | A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined by µCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% and µCT: 51.8% and 62.0%, resp.). Mean BIC calculated by µCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 (p < 0.002) was found between 3D and 2D quantification of BIC. The μCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface. |
format | Online Article Text |
id | pubmed-4430627 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-44306272015-06-10 Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry Gabler, Carolin Zietz, Carmen Bieck, Richard Göhler, Rebecca Lindner, Tobias Haenle, Maximilian Finke, Birgit Meichsner, Jürgen Testrich, Holger Nowottnick, Mathias Frerich, Bernhard Bader, Rainer Biomed Res Int Research Article A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means of µCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined by µCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% and µCT: 51.8% and 62.0%, resp.). Mean BIC calculated by µCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 (p < 0.002) was found between 3D and 2D quantification of BIC. The μCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface. Hindawi Publishing Corporation 2015 2015-04-30 /pmc/articles/PMC4430627/ /pubmed/26064874 http://dx.doi.org/10.1155/2015/103137 Text en Copyright © 2015 Carolin Gabler et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Gabler, Carolin Zietz, Carmen Bieck, Richard Göhler, Rebecca Lindner, Tobias Haenle, Maximilian Finke, Birgit Meichsner, Jürgen Testrich, Holger Nowottnick, Mathias Frerich, Bernhard Bader, Rainer Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry |
title | Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry |
title_full | Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry |
title_fullStr | Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry |
title_full_unstemmed | Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry |
title_short | Quantification of Osseointegration of Plasma-Polymer Coated Titanium Alloyed Implants by means of Microcomputed Tomography versus Histomorphometry |
title_sort | quantification of osseointegration of plasma-polymer coated titanium alloyed implants by means of microcomputed tomography versus histomorphometry |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4430627/ https://www.ncbi.nlm.nih.gov/pubmed/26064874 http://dx.doi.org/10.1155/2015/103137 |
work_keys_str_mv | AT gablercarolin quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT zietzcarmen quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT bieckrichard quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT gohlerrebecca quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT lindnertobias quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT haenlemaximilian quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT finkebirgit quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT meichsnerjurgen quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT testrichholger quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT nowottnickmathias quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT frerichbernhard quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry AT baderrainer quantificationofosseointegrationofplasmapolymercoatedtitaniumalloyedimplantsbymeansofmicrocomputedtomographyversushistomorphometry |