Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment

Partial discharge (PD) measurements provide valuable information for assessing the condition of high voltage (HV) insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years specially designed to perform on-line measurements. N...

Descripción completa

Detalles Bibliográficos
Autores principales: Álvarez, Fernando, Garnacho, Fernando, Ortego, Javier, Sánchez-Urán, Miguel Ángel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431200/
https://www.ncbi.nlm.nih.gov/pubmed/25815452
http://dx.doi.org/10.3390/s150407360
_version_ 1782371296643907584
author Álvarez, Fernando
Garnacho, Fernando
Ortego, Javier
Sánchez-Urán, Miguel Ángel
author_facet Álvarez, Fernando
Garnacho, Fernando
Ortego, Javier
Sánchez-Urán, Miguel Ángel
author_sort Álvarez, Fernando
collection PubMed
description Partial discharge (PD) measurements provide valuable information for assessing the condition of high voltage (HV) insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years specially designed to perform on-line measurements. Non-conventional PD methods operating in high frequency bands are usually used when this type of tests are carried out. In PD measurements the signal acquisition, the subsequent signal processing and the capability to obtain an accurate diagnosis are conditioned by the selection of a suitable detection technique and by the implementation of effective signal processing tools. This paper proposes an optimized electromagnetic detection method based on the combined use of wideband PD sensors for measurements performed in the HF and UHF frequency ranges, together with the implementation of powerful processing tools. The effectiveness of the measuring techniques proposed is demonstrated through an example, where several PD sources are measured simultaneously in a HV installation consisting of a cable system connected by a plug-in terminal to a gas insulated substation (GIS) compartment.
format Online
Article
Text
id pubmed-4431200
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-44312002015-05-19 Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment Álvarez, Fernando Garnacho, Fernando Ortego, Javier Sánchez-Urán, Miguel Ángel Sensors (Basel) Article Partial discharge (PD) measurements provide valuable information for assessing the condition of high voltage (HV) insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years specially designed to perform on-line measurements. Non-conventional PD methods operating in high frequency bands are usually used when this type of tests are carried out. In PD measurements the signal acquisition, the subsequent signal processing and the capability to obtain an accurate diagnosis are conditioned by the selection of a suitable detection technique and by the implementation of effective signal processing tools. This paper proposes an optimized electromagnetic detection method based on the combined use of wideband PD sensors for measurements performed in the HF and UHF frequency ranges, together with the implementation of powerful processing tools. The effectiveness of the measuring techniques proposed is demonstrated through an example, where several PD sources are measured simultaneously in a HV installation consisting of a cable system connected by a plug-in terminal to a gas insulated substation (GIS) compartment. MDPI 2015-03-25 /pmc/articles/PMC4431200/ /pubmed/25815452 http://dx.doi.org/10.3390/s150407360 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Álvarez, Fernando
Garnacho, Fernando
Ortego, Javier
Sánchez-Urán, Miguel Ángel
Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment
title Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment
title_full Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment
title_fullStr Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment
title_full_unstemmed Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment
title_short Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment
title_sort application of hfct and uhf sensors in on-line partial discharge measurements for insulation diagnosis of high voltage equipment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431200/
https://www.ncbi.nlm.nih.gov/pubmed/25815452
http://dx.doi.org/10.3390/s150407360
work_keys_str_mv AT alvarezfernando applicationofhfctanduhfsensorsinonlinepartialdischargemeasurementsforinsulationdiagnosisofhighvoltageequipment
AT garnachofernando applicationofhfctanduhfsensorsinonlinepartialdischargemeasurementsforinsulationdiagnosisofhighvoltageequipment
AT ortegojavier applicationofhfctanduhfsensorsinonlinepartialdischargemeasurementsforinsulationdiagnosisofhighvoltageequipment
AT sanchezuranmiguelangel applicationofhfctanduhfsensorsinonlinepartialdischargemeasurementsforinsulationdiagnosisofhighvoltageequipment