Cargando…

The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt

Respiratory and heart failure are conditions that can occur with little warning and may also be difficult to predict. Therefore continuous monitoring of these bio-signals is advantageous for ensuring human health. The car safety belt is mainly designed to secure the occupants of the vehicle in the e...

Descripción completa

Detalles Bibliográficos
Autores principales: Hamdani, Syed Talha Ali, Fernando, Anura
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431243/
https://www.ncbi.nlm.nih.gov/pubmed/25831088
http://dx.doi.org/10.3390/s150407742
_version_ 1782371306441801728
author Hamdani, Syed Talha Ali
Fernando, Anura
author_facet Hamdani, Syed Talha Ali
Fernando, Anura
author_sort Hamdani, Syed Talha Ali
collection PubMed
description Respiratory and heart failure are conditions that can occur with little warning and may also be difficult to predict. Therefore continuous monitoring of these bio-signals is advantageous for ensuring human health. The car safety belt is mainly designed to secure the occupants of the vehicle in the event of an accident. In the current research a prototype safety belt is developed, which is used to acquire respiratory and heart signals, under laboratory conditions. The current safety belt is constructed using a copper ink based nonwoven material, which works based on the piezo-resistive effect due to the pressure exerted on the sensor as a result of expansion of the thorax/abdomen area of the body for respiration and due to the principle of ballistocardiography (BCG) in heart signal sensing. In this research, the development of a theoretical model to qualitatively describe the piezo-resistive material is also presented in order to predict the relative change in the resistance of the piezo-resistive material due to the pressure applied.
format Online
Article
Text
id pubmed-4431243
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-44312432015-05-19 The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt Hamdani, Syed Talha Ali Fernando, Anura Sensors (Basel) Article Respiratory and heart failure are conditions that can occur with little warning and may also be difficult to predict. Therefore continuous monitoring of these bio-signals is advantageous for ensuring human health. The car safety belt is mainly designed to secure the occupants of the vehicle in the event of an accident. In the current research a prototype safety belt is developed, which is used to acquire respiratory and heart signals, under laboratory conditions. The current safety belt is constructed using a copper ink based nonwoven material, which works based on the piezo-resistive effect due to the pressure exerted on the sensor as a result of expansion of the thorax/abdomen area of the body for respiration and due to the principle of ballistocardiography (BCG) in heart signal sensing. In this research, the development of a theoretical model to qualitatively describe the piezo-resistive material is also presented in order to predict the relative change in the resistance of the piezo-resistive material due to the pressure applied. MDPI 2015-03-30 /pmc/articles/PMC4431243/ /pubmed/25831088 http://dx.doi.org/10.3390/s150407742 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hamdani, Syed Talha Ali
Fernando, Anura
The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt
title The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt
title_full The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt
title_fullStr The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt
title_full_unstemmed The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt
title_short The Application of a Piezo-Resistive Cardiorespiratory Sensor System in an Automobile Safety Belt
title_sort application of a piezo-resistive cardiorespiratory sensor system in an automobile safety belt
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431243/
https://www.ncbi.nlm.nih.gov/pubmed/25831088
http://dx.doi.org/10.3390/s150407742
work_keys_str_mv AT hamdanisyedtalhaali theapplicationofapiezoresistivecardiorespiratorysensorsysteminanautomobilesafetybelt
AT fernandoanura theapplicationofapiezoresistivecardiorespiratorysensorsysteminanautomobilesafetybelt
AT hamdanisyedtalhaali applicationofapiezoresistivecardiorespiratorysensorsysteminanautomobilesafetybelt
AT fernandoanura applicationofapiezoresistivecardiorespiratorysensorsysteminanautomobilesafetybelt