Cargando…

A Simple Method for Decreasing the Liquid Junction Potential in a Flow-through-Type Differential pH Sensor Probe Consisting of pH-FETs by Exerting Spatiotemporal Control of the Liquid Junction

The liquid junction potential (LJP), the phenomenon that occurs when two electrolyte solutions of different composition come into contact, prevents accurate measurements in potentiometry. The effect of the LJP is usually remarkable in measurements of diluted solutions with low buffering capacities o...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamada, Akira, Mohri, Satoshi, Nakamura, Michihiro, Naruse, Keiji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431306/
https://www.ncbi.nlm.nih.gov/pubmed/25835300
http://dx.doi.org/10.3390/s150407898
_version_ 1782371320931024896
author Yamada, Akira
Mohri, Satoshi
Nakamura, Michihiro
Naruse, Keiji
author_facet Yamada, Akira
Mohri, Satoshi
Nakamura, Michihiro
Naruse, Keiji
author_sort Yamada, Akira
collection PubMed
description The liquid junction potential (LJP), the phenomenon that occurs when two electrolyte solutions of different composition come into contact, prevents accurate measurements in potentiometry. The effect of the LJP is usually remarkable in measurements of diluted solutions with low buffering capacities or low ion concentrations. Our group has constructed a simple method to eliminate the LJP by exerting spatiotemporal control of a liquid junction (LJ) formed between two solutions, a sample solution and a baseline solution (BLS), in a flow-through-type differential pH sensor probe. The method was contrived based on microfluidics. The sensor probe is a differential measurement system composed of two ion-sensitive field-effect transistors (ISFETs) and one Ag/AgCl electrode. With our new method, the border region of the sample solution and BLS is vibrated in order to mix solutions and suppress the overshoot after the sample solution is suctioned into the sensor probe. Compared to the conventional method without vibration, our method shortened the settling time from over two min to 15 s and reduced the measurement error by 86% to within 0.060 pH. This new method will be useful for improving the response characteristics and decreasing the measurement error of many apparatuses that use LJs.
format Online
Article
Text
id pubmed-4431306
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-44313062015-05-19 A Simple Method for Decreasing the Liquid Junction Potential in a Flow-through-Type Differential pH Sensor Probe Consisting of pH-FETs by Exerting Spatiotemporal Control of the Liquid Junction Yamada, Akira Mohri, Satoshi Nakamura, Michihiro Naruse, Keiji Sensors (Basel) Article The liquid junction potential (LJP), the phenomenon that occurs when two electrolyte solutions of different composition come into contact, prevents accurate measurements in potentiometry. The effect of the LJP is usually remarkable in measurements of diluted solutions with low buffering capacities or low ion concentrations. Our group has constructed a simple method to eliminate the LJP by exerting spatiotemporal control of a liquid junction (LJ) formed between two solutions, a sample solution and a baseline solution (BLS), in a flow-through-type differential pH sensor probe. The method was contrived based on microfluidics. The sensor probe is a differential measurement system composed of two ion-sensitive field-effect transistors (ISFETs) and one Ag/AgCl electrode. With our new method, the border region of the sample solution and BLS is vibrated in order to mix solutions and suppress the overshoot after the sample solution is suctioned into the sensor probe. Compared to the conventional method without vibration, our method shortened the settling time from over two min to 15 s and reduced the measurement error by 86% to within 0.060 pH. This new method will be useful for improving the response characteristics and decreasing the measurement error of many apparatuses that use LJs. MDPI 2015-04-01 /pmc/articles/PMC4431306/ /pubmed/25835300 http://dx.doi.org/10.3390/s150407898 Text en © 2015 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yamada, Akira
Mohri, Satoshi
Nakamura, Michihiro
Naruse, Keiji
A Simple Method for Decreasing the Liquid Junction Potential in a Flow-through-Type Differential pH Sensor Probe Consisting of pH-FETs by Exerting Spatiotemporal Control of the Liquid Junction
title A Simple Method for Decreasing the Liquid Junction Potential in a Flow-through-Type Differential pH Sensor Probe Consisting of pH-FETs by Exerting Spatiotemporal Control of the Liquid Junction
title_full A Simple Method for Decreasing the Liquid Junction Potential in a Flow-through-Type Differential pH Sensor Probe Consisting of pH-FETs by Exerting Spatiotemporal Control of the Liquid Junction
title_fullStr A Simple Method for Decreasing the Liquid Junction Potential in a Flow-through-Type Differential pH Sensor Probe Consisting of pH-FETs by Exerting Spatiotemporal Control of the Liquid Junction
title_full_unstemmed A Simple Method for Decreasing the Liquid Junction Potential in a Flow-through-Type Differential pH Sensor Probe Consisting of pH-FETs by Exerting Spatiotemporal Control of the Liquid Junction
title_short A Simple Method for Decreasing the Liquid Junction Potential in a Flow-through-Type Differential pH Sensor Probe Consisting of pH-FETs by Exerting Spatiotemporal Control of the Liquid Junction
title_sort simple method for decreasing the liquid junction potential in a flow-through-type differential ph sensor probe consisting of ph-fets by exerting spatiotemporal control of the liquid junction
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431306/
https://www.ncbi.nlm.nih.gov/pubmed/25835300
http://dx.doi.org/10.3390/s150407898
work_keys_str_mv AT yamadaakira asimplemethodfordecreasingtheliquidjunctionpotentialinaflowthroughtypedifferentialphsensorprobeconsistingofphfetsbyexertingspatiotemporalcontroloftheliquidjunction
AT mohrisatoshi asimplemethodfordecreasingtheliquidjunctionpotentialinaflowthroughtypedifferentialphsensorprobeconsistingofphfetsbyexertingspatiotemporalcontroloftheliquidjunction
AT nakamuramichihiro asimplemethodfordecreasingtheliquidjunctionpotentialinaflowthroughtypedifferentialphsensorprobeconsistingofphfetsbyexertingspatiotemporalcontroloftheliquidjunction
AT narusekeiji asimplemethodfordecreasingtheliquidjunctionpotentialinaflowthroughtypedifferentialphsensorprobeconsistingofphfetsbyexertingspatiotemporalcontroloftheliquidjunction
AT yamadaakira simplemethodfordecreasingtheliquidjunctionpotentialinaflowthroughtypedifferentialphsensorprobeconsistingofphfetsbyexertingspatiotemporalcontroloftheliquidjunction
AT mohrisatoshi simplemethodfordecreasingtheliquidjunctionpotentialinaflowthroughtypedifferentialphsensorprobeconsistingofphfetsbyexertingspatiotemporalcontroloftheliquidjunction
AT nakamuramichihiro simplemethodfordecreasingtheliquidjunctionpotentialinaflowthroughtypedifferentialphsensorprobeconsistingofphfetsbyexertingspatiotemporalcontroloftheliquidjunction
AT narusekeiji simplemethodfordecreasingtheliquidjunctionpotentialinaflowthroughtypedifferentialphsensorprobeconsistingofphfetsbyexertingspatiotemporalcontroloftheliquidjunction