Does routine repeat testing of critical laboratory values improve their accuracy?
Background: Routine repeat testing of critical laboratory values is very common these days to increase their accuracy and to avoid reporting false or infeasible results. We figure that repeat testing of critical laboratory values has any benefits or not. Methods: We examined 2233 repeated critical l...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iran University of Medical Sciences
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431443/ https://www.ncbi.nlm.nih.gov/pubmed/26034729 |
_version_ | 1782371351930077184 |
---|---|
author | Baradaran Motie, Pooya Zare-Mirzaie, Ali Shayanfar, Nasrin Kadivar, Maryam |
author_facet | Baradaran Motie, Pooya Zare-Mirzaie, Ali Shayanfar, Nasrin Kadivar, Maryam |
author_sort | Baradaran Motie, Pooya |
collection | PubMed |
description | Background: Routine repeat testing of critical laboratory values is very common these days to increase their accuracy and to avoid reporting false or infeasible results. We figure that repeat testing of critical laboratory values has any benefits or not. Methods: We examined 2233 repeated critical laboratory values in 13 different hematology and chemistry tests including: hemoglobin, white blood cell, platelet, international normalized ratio, partial thromboplastin time, glucose, potassium, sodium, phosphorus, magnesium, calcium, total bilirubin and direct bilirubin. The absolute difference and the percentage of change between the two tests for each critical value were calculated and then compared with the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error. Results: Repeat testing yielded results that were within the allowable error on 2213 of 2233 specimens (99.1%). There was only one outlier (0.2%) in the white blood cell test category, 9 (2.9%) in the platelet test category, 5 (4%) in the partial thromboplastin time test category, 5 (4.8%) in the international normalized ratio test category and none in other test categories. Conclusion: Routine, repeat testing of critical hemoglobin, white blood cell, platelet, international normalized ratio, partial thromboplastin time, glucose, potassium, sodium, phosphorus, magnesium, calcium, total bilirubin and direct bilirubin results does not have any benefits to increase their accuracy. |
format | Online Article Text |
id | pubmed-4431443 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Iran University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-44314432015-06-01 Does routine repeat testing of critical laboratory values improve their accuracy? Baradaran Motie, Pooya Zare-Mirzaie, Ali Shayanfar, Nasrin Kadivar, Maryam Med J Islam Repub Iran Original Article Background: Routine repeat testing of critical laboratory values is very common these days to increase their accuracy and to avoid reporting false or infeasible results. We figure that repeat testing of critical laboratory values has any benefits or not. Methods: We examined 2233 repeated critical laboratory values in 13 different hematology and chemistry tests including: hemoglobin, white blood cell, platelet, international normalized ratio, partial thromboplastin time, glucose, potassium, sodium, phosphorus, magnesium, calcium, total bilirubin and direct bilirubin. The absolute difference and the percentage of change between the two tests for each critical value were calculated and then compared with the College of American Pathologists/Clinical Laboratory Improvement Amendments allowable error. Results: Repeat testing yielded results that were within the allowable error on 2213 of 2233 specimens (99.1%). There was only one outlier (0.2%) in the white blood cell test category, 9 (2.9%) in the platelet test category, 5 (4%) in the partial thromboplastin time test category, 5 (4.8%) in the international normalized ratio test category and none in other test categories. Conclusion: Routine, repeat testing of critical hemoglobin, white blood cell, platelet, international normalized ratio, partial thromboplastin time, glucose, potassium, sodium, phosphorus, magnesium, calcium, total bilirubin and direct bilirubin results does not have any benefits to increase their accuracy. Iran University of Medical Sciences 2015-02-09 /pmc/articles/PMC4431443/ /pubmed/26034729 Text en © 2015 Iran University of Medical Sciences http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly. |
spellingShingle | Original Article Baradaran Motie, Pooya Zare-Mirzaie, Ali Shayanfar, Nasrin Kadivar, Maryam Does routine repeat testing of critical laboratory values improve their accuracy? |
title | Does routine repeat testing of critical laboratory values improve their accuracy? |
title_full | Does routine repeat testing of critical laboratory values improve their accuracy? |
title_fullStr | Does routine repeat testing of critical laboratory values improve their accuracy? |
title_full_unstemmed | Does routine repeat testing of critical laboratory values improve their accuracy? |
title_short | Does routine repeat testing of critical laboratory values improve their accuracy? |
title_sort | does routine repeat testing of critical laboratory values improve their accuracy? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4431443/ https://www.ncbi.nlm.nih.gov/pubmed/26034729 |
work_keys_str_mv | AT baradaranmotiepooya doesroutinerepeattestingofcriticallaboratoryvaluesimprovetheiraccuracy AT zaremirzaieali doesroutinerepeattestingofcriticallaboratoryvaluesimprovetheiraccuracy AT shayanfarnasrin doesroutinerepeattestingofcriticallaboratoryvaluesimprovetheiraccuracy AT kadivarmaryam doesroutinerepeattestingofcriticallaboratoryvaluesimprovetheiraccuracy |