Cargando…

The effect of multiple processing and re-use on orthodontic mini-screw torque values

BACKGROUND: Reusing orthodontic mini-screws would reduce treatment cost and lead to more use of mini-screws and improvement of orthodontic treatments. This study has assessed the effects of reprocessing and reusing the titanium mini-screws on their maximum insertion, removal and fracture torque (FT)...

Descripción completa

Detalles Bibliográficos
Autores principales: Noorollahian, Saeed, Alavi, Shiva, Rafiei, Elahe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4432607/
https://www.ncbi.nlm.nih.gov/pubmed/26005464
_version_ 1782371511909220352
author Noorollahian, Saeed
Alavi, Shiva
Rafiei, Elahe
author_facet Noorollahian, Saeed
Alavi, Shiva
Rafiei, Elahe
author_sort Noorollahian, Saeed
collection PubMed
description BACKGROUND: Reusing orthodontic mini-screws would reduce treatment cost and lead to more use of mini-screws and improvement of orthodontic treatments. This study has assessed the effects of reprocessing and reusing the titanium mini-screws on their maximum insertion, removal and fracture torque (FT). MATERIALS AND METHODS: In this experimental study, 20 titanium mini-screws (1.6-mm × 8-mm) were randomly divided into two equal groups. In the test group, the screws were first sterilized by autoclave and then their FT was assessed. In the control group, FT was assessed after 5 times of insertion, cleaning, processing (37% phosphoric acid for 10 min, 5.25% sodium hypochlorite for 30 min) and sterilizing with autoclave. The maximum insertion and removal torque values were compared using the repeated measure ANOVA and the FT data were analyzed by the t-test. The data were analyzed using the SPSS software (version 13.0) and the significance was set on 0.05. RESULTS: The paired t-test for maximum insertion torque (MIT) showed that MIT(1) was significantly lower than other MIT values (P = 0.02) and also MIT(2) was significantly higher than MIT5 (P = 0.01), but other MIT values had no significant differences. The paired t-test for maximum removal torque (MRT) showed that only MRT(2) was significantly higher than other MRT values (except MRT(1)) (P = 0.046). Regarding FT, the t-test showed that there was no significant difference between FT(0) and FT(5) (P = 0.485). CONCLUSION: Within limitations of this study, five time insertion, cleaning, processing and steam sterilization had no significant negative effect on insertion, removal and FT of the mini-screws.
format Online
Article
Text
id pubmed-4432607
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-44326072015-05-22 The effect of multiple processing and re-use on orthodontic mini-screw torque values Noorollahian, Saeed Alavi, Shiva Rafiei, Elahe Dent Res J (Isfahan) Original Article BACKGROUND: Reusing orthodontic mini-screws would reduce treatment cost and lead to more use of mini-screws and improvement of orthodontic treatments. This study has assessed the effects of reprocessing and reusing the titanium mini-screws on their maximum insertion, removal and fracture torque (FT). MATERIALS AND METHODS: In this experimental study, 20 titanium mini-screws (1.6-mm × 8-mm) were randomly divided into two equal groups. In the test group, the screws were first sterilized by autoclave and then their FT was assessed. In the control group, FT was assessed after 5 times of insertion, cleaning, processing (37% phosphoric acid for 10 min, 5.25% sodium hypochlorite for 30 min) and sterilizing with autoclave. The maximum insertion and removal torque values were compared using the repeated measure ANOVA and the FT data were analyzed by the t-test. The data were analyzed using the SPSS software (version 13.0) and the significance was set on 0.05. RESULTS: The paired t-test for maximum insertion torque (MIT) showed that MIT(1) was significantly lower than other MIT values (P = 0.02) and also MIT(2) was significantly higher than MIT5 (P = 0.01), but other MIT values had no significant differences. The paired t-test for maximum removal torque (MRT) showed that only MRT(2) was significantly higher than other MRT values (except MRT(1)) (P = 0.046). Regarding FT, the t-test showed that there was no significant difference between FT(0) and FT(5) (P = 0.485). CONCLUSION: Within limitations of this study, five time insertion, cleaning, processing and steam sterilization had no significant negative effect on insertion, removal and FT of the mini-screws. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4432607/ /pubmed/26005464 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Noorollahian, Saeed
Alavi, Shiva
Rafiei, Elahe
The effect of multiple processing and re-use on orthodontic mini-screw torque values
title The effect of multiple processing and re-use on orthodontic mini-screw torque values
title_full The effect of multiple processing and re-use on orthodontic mini-screw torque values
title_fullStr The effect of multiple processing and re-use on orthodontic mini-screw torque values
title_full_unstemmed The effect of multiple processing and re-use on orthodontic mini-screw torque values
title_short The effect of multiple processing and re-use on orthodontic mini-screw torque values
title_sort effect of multiple processing and re-use on orthodontic mini-screw torque values
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4432607/
https://www.ncbi.nlm.nih.gov/pubmed/26005464
work_keys_str_mv AT noorollahiansaeed theeffectofmultipleprocessingandreuseonorthodonticminiscrewtorquevalues
AT alavishiva theeffectofmultipleprocessingandreuseonorthodonticminiscrewtorquevalues
AT rafieielahe theeffectofmultipleprocessingandreuseonorthodonticminiscrewtorquevalues
AT noorollahiansaeed effectofmultipleprocessingandreuseonorthodonticminiscrewtorquevalues
AT alavishiva effectofmultipleprocessingandreuseonorthodonticminiscrewtorquevalues
AT rafieielahe effectofmultipleprocessingandreuseonorthodonticminiscrewtorquevalues