Cargando…

Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography

PURPOSE: To evaluate the diagnostic ability of macular ganglion cell and inner plexiform layer measurements in glaucoma, obtained using swept source (SS) and spectral domain (SD) optical coherence tomography (OCT) and to compare to circumpapillary retinal nerve fiber layer (cpRNFL) thickness measure...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Zhiyong, Tatham, Andrew J., Weinreb, Robert N., Medeiros, Felipe A., Liu, Ting, Zangwill, Linda M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4433247/
https://www.ncbi.nlm.nih.gov/pubmed/25978420
http://dx.doi.org/10.1371/journal.pone.0125957
_version_ 1782371611601534976
author Yang, Zhiyong
Tatham, Andrew J.
Weinreb, Robert N.
Medeiros, Felipe A.
Liu, Ting
Zangwill, Linda M.
author_facet Yang, Zhiyong
Tatham, Andrew J.
Weinreb, Robert N.
Medeiros, Felipe A.
Liu, Ting
Zangwill, Linda M.
author_sort Yang, Zhiyong
collection PubMed
description PURPOSE: To evaluate the diagnostic ability of macular ganglion cell and inner plexiform layer measurements in glaucoma, obtained using swept source (SS) and spectral domain (SD) optical coherence tomography (OCT) and to compare to circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements. METHODS: The study included 106 glaucomatous eyes of 80 subjects and 41 eyes of 22 healthy subjects from the Diagnostic Innovations in Glaucoma Study. Macular ganglion cell and inner plexiform layer (mGCIPL), macular ganglion cell complex (mGCC) and cpRNFL thickness were assessed using SS-OCT and SD-OCT, and area under the receiver operating characteristic curves (AUCs) were calculated to determine ability to differentiate glaucomatous and healthy eyes and between early glaucomatous and healthy eyes. RESULTS: Mean (± standard deviation) mGCIPL and mGCC thickness were thinner in both healthy and glaucomatous eyes using SS-OCT compared to using SD-OCT. Fixed and proportional biases were detected between SS-OCT and SD-OCT measures. Diagnostic accuracy (AUCs) for differentiating between healthy and glaucomatous eyes for average and sectoral mGCIPL was similar in SS-OCT (0.65 to 0.81) and SD-OCT (0.63 to 0.83). AUCs for average cpRNFL acquired using SS-OCT and SD-OCT tended to be higher (0.83 and 0.85, respectively) than for average mGCC (0.82 and 0.78, respectively), and mGCIPL (0.73 and 0.75, respectively) but these differences did not consistently reach statistical significance. Minimum SD-OCT mGCIPL and mGCC thickness (unavailable in SS-OCT) had the highest AUC (0.86) among macular measurements. CONCLUSION: Assessment of mGCIPL thickness using SS-OCT or SD-OCT is useful for detecting glaucomatous damage, but measurements are not interchangeable for patient management decisions. Diagnostic accuracies of mGCIPL and mGCC from both SS-OCT and SD-OCT were similar to that of cpRNFL for glaucoma detection.
format Online
Article
Text
id pubmed-4433247
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-44332472015-05-27 Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography Yang, Zhiyong Tatham, Andrew J. Weinreb, Robert N. Medeiros, Felipe A. Liu, Ting Zangwill, Linda M. PLoS One Research Article PURPOSE: To evaluate the diagnostic ability of macular ganglion cell and inner plexiform layer measurements in glaucoma, obtained using swept source (SS) and spectral domain (SD) optical coherence tomography (OCT) and to compare to circumpapillary retinal nerve fiber layer (cpRNFL) thickness measurements. METHODS: The study included 106 glaucomatous eyes of 80 subjects and 41 eyes of 22 healthy subjects from the Diagnostic Innovations in Glaucoma Study. Macular ganglion cell and inner plexiform layer (mGCIPL), macular ganglion cell complex (mGCC) and cpRNFL thickness were assessed using SS-OCT and SD-OCT, and area under the receiver operating characteristic curves (AUCs) were calculated to determine ability to differentiate glaucomatous and healthy eyes and between early glaucomatous and healthy eyes. RESULTS: Mean (± standard deviation) mGCIPL and mGCC thickness were thinner in both healthy and glaucomatous eyes using SS-OCT compared to using SD-OCT. Fixed and proportional biases were detected between SS-OCT and SD-OCT measures. Diagnostic accuracy (AUCs) for differentiating between healthy and glaucomatous eyes for average and sectoral mGCIPL was similar in SS-OCT (0.65 to 0.81) and SD-OCT (0.63 to 0.83). AUCs for average cpRNFL acquired using SS-OCT and SD-OCT tended to be higher (0.83 and 0.85, respectively) than for average mGCC (0.82 and 0.78, respectively), and mGCIPL (0.73 and 0.75, respectively) but these differences did not consistently reach statistical significance. Minimum SD-OCT mGCIPL and mGCC thickness (unavailable in SS-OCT) had the highest AUC (0.86) among macular measurements. CONCLUSION: Assessment of mGCIPL thickness using SS-OCT or SD-OCT is useful for detecting glaucomatous damage, but measurements are not interchangeable for patient management decisions. Diagnostic accuracies of mGCIPL and mGCC from both SS-OCT and SD-OCT were similar to that of cpRNFL for glaucoma detection. Public Library of Science 2015-05-15 /pmc/articles/PMC4433247/ /pubmed/25978420 http://dx.doi.org/10.1371/journal.pone.0125957 Text en © 2015 Yang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Yang, Zhiyong
Tatham, Andrew J.
Weinreb, Robert N.
Medeiros, Felipe A.
Liu, Ting
Zangwill, Linda M.
Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography
title Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography
title_full Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography
title_fullStr Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography
title_full_unstemmed Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography
title_short Diagnostic Ability of Macular Ganglion Cell Inner Plexiform Layer Measurements in Glaucoma Using Swept Source and Spectral Domain Optical Coherence Tomography
title_sort diagnostic ability of macular ganglion cell inner plexiform layer measurements in glaucoma using swept source and spectral domain optical coherence tomography
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4433247/
https://www.ncbi.nlm.nih.gov/pubmed/25978420
http://dx.doi.org/10.1371/journal.pone.0125957
work_keys_str_mv AT yangzhiyong diagnosticabilityofmacularganglioncellinnerplexiformlayermeasurementsinglaucomausingsweptsourceandspectraldomainopticalcoherencetomography
AT tathamandrewj diagnosticabilityofmacularganglioncellinnerplexiformlayermeasurementsinglaucomausingsweptsourceandspectraldomainopticalcoherencetomography
AT weinrebrobertn diagnosticabilityofmacularganglioncellinnerplexiformlayermeasurementsinglaucomausingsweptsourceandspectraldomainopticalcoherencetomography
AT medeirosfelipea diagnosticabilityofmacularganglioncellinnerplexiformlayermeasurementsinglaucomausingsweptsourceandspectraldomainopticalcoherencetomography
AT liuting diagnosticabilityofmacularganglioncellinnerplexiformlayermeasurementsinglaucomausingsweptsourceandspectraldomainopticalcoherencetomography
AT zangwilllindam diagnosticabilityofmacularganglioncellinnerplexiformlayermeasurementsinglaucomausingsweptsourceandspectraldomainopticalcoherencetomography