Evolution of mammographic image quality in the state of Rio de Janeiro
OBJECTIVE: To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011. MATERIALS AND METHODS: Descriptive study analyzing parameters connected with imag...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Colégio Brasileiro de Radiologia e Diagnóstico por
Imagem
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4433297/ https://www.ncbi.nlm.nih.gov/pubmed/25987749 http://dx.doi.org/10.1590/0100-3984.2014.0047 |
_version_ | 1782371622250872832 |
---|---|
author | Villar, Vanessa Cristina Felippe Lopes Seta, Marismary Horsth De de Andrade, Carla Lourenço Tavares Delamarque, Elizabete Vianna de Azevedo, Ana Cecília Pedrosa |
author_facet | Villar, Vanessa Cristina Felippe Lopes Seta, Marismary Horsth De de Andrade, Carla Lourenço Tavares Delamarque, Elizabete Vianna de Azevedo, Ana Cecília Pedrosa |
author_sort | Villar, Vanessa Cristina Felippe Lopes |
collection | PubMed |
description | OBJECTIVE: To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011. MATERIALS AND METHODS: Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval. RESULTS: Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%). CONCLUSION: The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval. |
format | Online Article Text |
id | pubmed-4433297 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Colégio Brasileiro de Radiologia e Diagnóstico por
Imagem |
record_format | MEDLINE/PubMed |
spelling | pubmed-44332972015-05-18 Evolution of mammographic image quality in the state of Rio de Janeiro Villar, Vanessa Cristina Felippe Lopes Seta, Marismary Horsth De de Andrade, Carla Lourenço Tavares Delamarque, Elizabete Vianna de Azevedo, Ana Cecília Pedrosa Radiol Bras Original Articles OBJECTIVE: To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011. MATERIALS AND METHODS: Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval. RESULTS: Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%). CONCLUSION: The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval. Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2015 /pmc/articles/PMC4433297/ /pubmed/25987749 http://dx.doi.org/10.1590/0100-3984.2014.0047 Text en © Colégio Brasileiro de Radiologia e Diagnóstico por Imagem http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles Villar, Vanessa Cristina Felippe Lopes Seta, Marismary Horsth De de Andrade, Carla Lourenço Tavares Delamarque, Elizabete Vianna de Azevedo, Ana Cecília Pedrosa Evolution of mammographic image quality in the state of Rio de Janeiro |
title | Evolution of mammographic image quality in the state of Rio de
Janeiro |
title_full | Evolution of mammographic image quality in the state of Rio de
Janeiro |
title_fullStr | Evolution of mammographic image quality in the state of Rio de
Janeiro |
title_full_unstemmed | Evolution of mammographic image quality in the state of Rio de
Janeiro |
title_short | Evolution of mammographic image quality in the state of Rio de
Janeiro |
title_sort | evolution of mammographic image quality in the state of rio de
janeiro |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4433297/ https://www.ncbi.nlm.nih.gov/pubmed/25987749 http://dx.doi.org/10.1590/0100-3984.2014.0047 |
work_keys_str_mv | AT villarvanessacristinafelippelopes evolutionofmammographicimagequalityinthestateofriodejaneiro AT setamarismaryhorsthde evolutionofmammographicimagequalityinthestateofriodejaneiro AT deandradecarlalourencotavares evolutionofmammographicimagequalityinthestateofriodejaneiro AT delamarqueelizabetevianna evolutionofmammographicimagequalityinthestateofriodejaneiro AT deazevedoanaceciliapedrosa evolutionofmammographicimagequalityinthestateofriodejaneiro |