Cargando…

Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test

[Purpose] The purpose of this study was to determine the inter- and intra-examiner reliability of measurement methods for femoral anterversion during Craig’s test. [Subjects and Methods] The study included 37 healthy participants (20 males and 17 females). Two novice examiners (Department of Physica...

Descripción completa

Detalles Bibliográficos
Autores principales: Choi, Bo-ram, Kang, Sun-young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4433996/
https://www.ncbi.nlm.nih.gov/pubmed/25995575
http://dx.doi.org/10.1589/jpts.27.1141
_version_ 1782371703822745600
author Choi, Bo-ram
Kang, Sun-young
author_facet Choi, Bo-ram
Kang, Sun-young
author_sort Choi, Bo-ram
collection PubMed
description [Purpose] The purpose of this study was to determine the inter- and intra-examiner reliability of measurement methods for femoral anterversion during Craig’s test. [Subjects and Methods] The study included 37 healthy participants (20 males and 17 females). Two novice examiners (Department of Physical Therapy students at Silla University) used three different methods to measure the femoral anterversion during Craig’s test: a goniometer, a goniometer with a laser beam, and an inclinometer. [Results] The intra-examiner reliability was high for both examiners with all three measurement methods, with scores of 0.82, 0.86, and 0.73 for examiner 1 and 0.74, 0.78, and 0.72 for examiner 2 for the goniometer, goniometer with the laser beam, and inclinometer, respectively. The inter-examiner reliability during Craig’s test was below moderate for both the goniometer (0.25) and inclinometer (0.27) and moderate for the goniometer with the laser beam (0.62). [Conclusion] This study found that Craig’s test using a goniometer with a laser beam had high intra-examiner reliability and moderate inter-examiner reliability. Clinically, these findings may supplement existing measurement skills and reduce the difficulty of locating the goniometer axis during Craig’s test.
format Online
Article
Text
id pubmed-4433996
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-44339962015-05-20 Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test Choi, Bo-ram Kang, Sun-young J Phys Ther Sci Original Article [Purpose] The purpose of this study was to determine the inter- and intra-examiner reliability of measurement methods for femoral anterversion during Craig’s test. [Subjects and Methods] The study included 37 healthy participants (20 males and 17 females). Two novice examiners (Department of Physical Therapy students at Silla University) used three different methods to measure the femoral anterversion during Craig’s test: a goniometer, a goniometer with a laser beam, and an inclinometer. [Results] The intra-examiner reliability was high for both examiners with all three measurement methods, with scores of 0.82, 0.86, and 0.73 for examiner 1 and 0.74, 0.78, and 0.72 for examiner 2 for the goniometer, goniometer with the laser beam, and inclinometer, respectively. The inter-examiner reliability during Craig’s test was below moderate for both the goniometer (0.25) and inclinometer (0.27) and moderate for the goniometer with the laser beam (0.62). [Conclusion] This study found that Craig’s test using a goniometer with a laser beam had high intra-examiner reliability and moderate inter-examiner reliability. Clinically, these findings may supplement existing measurement skills and reduce the difficulty of locating the goniometer axis during Craig’s test. The Society of Physical Therapy Science 2015-04-30 2015-04 /pmc/articles/PMC4433996/ /pubmed/25995575 http://dx.doi.org/10.1589/jpts.27.1141 Text en 2015©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
spellingShingle Original Article
Choi, Bo-ram
Kang, Sun-young
Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test
title Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test
title_full Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test
title_fullStr Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test
title_full_unstemmed Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test
title_short Intra- and inter-examiner reliability of goniometer and inclinometer use in Craig’s test
title_sort intra- and inter-examiner reliability of goniometer and inclinometer use in craig’s test
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4433996/
https://www.ncbi.nlm.nih.gov/pubmed/25995575
http://dx.doi.org/10.1589/jpts.27.1141
work_keys_str_mv AT choiboram intraandinterexaminerreliabilityofgoniometerandinclinometeruseincraigstest
AT kangsunyoung intraandinterexaminerreliabilityofgoniometerandinclinometeruseincraigstest