Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality
OBJECTIVE: To assess the lesion conspicuity and image quality in CT evaluation of small (≤ 3 cm) hepatocellular carcinomas (HCCs) using automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) with or without iterative reconstruction. MATERIALS AND METHODS: One hundred an...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435983/ https://www.ncbi.nlm.nih.gov/pubmed/25995682 http://dx.doi.org/10.3348/kjr.2015.16.3.531 |
_version_ | 1782371983043854336 |
---|---|
author | Lv, Peijie Liu, Jie Zhang, Rui Jia, Yan Gao, Jianbo |
author_facet | Lv, Peijie Liu, Jie Zhang, Rui Jia, Yan Gao, Jianbo |
author_sort | Lv, Peijie |
collection | PubMed |
description | OBJECTIVE: To assess the lesion conspicuity and image quality in CT evaluation of small (≤ 3 cm) hepatocellular carcinomas (HCCs) using automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) with or without iterative reconstruction. MATERIALS AND METHODS: One hundred and five patients with 123 HCC lesions were included. Fifty-seven patients were scanned using both ATVS and ATCM and images were reconstructed using either filtered back-projection (FBP) (group A1) or sinogram-affirmed iterative reconstruction (SAFIRE) (group A2). Forty-eight patients were imaged using only ATCM, with a fixed tube potential of 120 kVp and FBP reconstruction (group B). Quantitative parameters (image noise in Hounsfield unit and contrast-to-noise ratio of the aorta, the liver, and the hepatic tumors) and qualitative visual parameters (image noise, overall image quality, and lesion conspicuity as graded on a 5-point scale) were compared among the groups. RESULTS: Group A2 scanned with the automatically chosen 80 kVp and 100 kVp tube voltages ranked the best in lesion conspicuity and subjective and objective image quality (p values ranging from < 0.001 to 0.004) among the three groups, except for overall image quality between group A2 and group B (p = 0.022). Group A1 showed higher image noise (p = 0.005) but similar lesion conspicuity and overall image quality as compared with group B. The radiation dose in group A was 19% lower than that in group B (p = 0.022). CONCLUSION: CT scanning with combined use of ATVS and ATCM and image reconstruction with SAFIRE algorithm provides higher lesion conspicuity and better image quality for evaluating small hepatic HCCs with radiation dose reduction. |
format | Online Article Text |
id | pubmed-4435983 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-44359832015-05-20 Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality Lv, Peijie Liu, Jie Zhang, Rui Jia, Yan Gao, Jianbo Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To assess the lesion conspicuity and image quality in CT evaluation of small (≤ 3 cm) hepatocellular carcinomas (HCCs) using automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) with or without iterative reconstruction. MATERIALS AND METHODS: One hundred and five patients with 123 HCC lesions were included. Fifty-seven patients were scanned using both ATVS and ATCM and images were reconstructed using either filtered back-projection (FBP) (group A1) or sinogram-affirmed iterative reconstruction (SAFIRE) (group A2). Forty-eight patients were imaged using only ATCM, with a fixed tube potential of 120 kVp and FBP reconstruction (group B). Quantitative parameters (image noise in Hounsfield unit and contrast-to-noise ratio of the aorta, the liver, and the hepatic tumors) and qualitative visual parameters (image noise, overall image quality, and lesion conspicuity as graded on a 5-point scale) were compared among the groups. RESULTS: Group A2 scanned with the automatically chosen 80 kVp and 100 kVp tube voltages ranked the best in lesion conspicuity and subjective and objective image quality (p values ranging from < 0.001 to 0.004) among the three groups, except for overall image quality between group A2 and group B (p = 0.022). Group A1 showed higher image noise (p = 0.005) but similar lesion conspicuity and overall image quality as compared with group B. The radiation dose in group A was 19% lower than that in group B (p = 0.022). CONCLUSION: CT scanning with combined use of ATVS and ATCM and image reconstruction with SAFIRE algorithm provides higher lesion conspicuity and better image quality for evaluating small hepatic HCCs with radiation dose reduction. The Korean Society of Radiology 2015 2015-05-13 /pmc/articles/PMC4435983/ /pubmed/25995682 http://dx.doi.org/10.3348/kjr.2015.16.3.531 Text en Copyright © 2015 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Gastrointestinal Imaging Lv, Peijie Liu, Jie Zhang, Rui Jia, Yan Gao, Jianbo Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality |
title | Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality |
title_full | Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality |
title_fullStr | Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality |
title_full_unstemmed | Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality |
title_short | Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality |
title_sort | combined use of automatic tube voltage selection and current modulation with iterative reconstruction for ct evaluation of small hypervascular hepatocellular carcinomas: effect on lesion conspicuity and image quality |
topic | Gastrointestinal Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435983/ https://www.ncbi.nlm.nih.gov/pubmed/25995682 http://dx.doi.org/10.3348/kjr.2015.16.3.531 |
work_keys_str_mv | AT lvpeijie combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality AT liujie combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality AT zhangrui combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality AT jiayan combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality AT gaojianbo combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality |