Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality

OBJECTIVE: To assess the lesion conspicuity and image quality in CT evaluation of small (≤ 3 cm) hepatocellular carcinomas (HCCs) using automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) with or without iterative reconstruction. MATERIALS AND METHODS: One hundred an...

Descripción completa

Detalles Bibliográficos
Autores principales: Lv, Peijie, Liu, Jie, Zhang, Rui, Jia, Yan, Gao, Jianbo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435983/
https://www.ncbi.nlm.nih.gov/pubmed/25995682
http://dx.doi.org/10.3348/kjr.2015.16.3.531
_version_ 1782371983043854336
author Lv, Peijie
Liu, Jie
Zhang, Rui
Jia, Yan
Gao, Jianbo
author_facet Lv, Peijie
Liu, Jie
Zhang, Rui
Jia, Yan
Gao, Jianbo
author_sort Lv, Peijie
collection PubMed
description OBJECTIVE: To assess the lesion conspicuity and image quality in CT evaluation of small (≤ 3 cm) hepatocellular carcinomas (HCCs) using automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) with or without iterative reconstruction. MATERIALS AND METHODS: One hundred and five patients with 123 HCC lesions were included. Fifty-seven patients were scanned using both ATVS and ATCM and images were reconstructed using either filtered back-projection (FBP) (group A1) or sinogram-affirmed iterative reconstruction (SAFIRE) (group A2). Forty-eight patients were imaged using only ATCM, with a fixed tube potential of 120 kVp and FBP reconstruction (group B). Quantitative parameters (image noise in Hounsfield unit and contrast-to-noise ratio of the aorta, the liver, and the hepatic tumors) and qualitative visual parameters (image noise, overall image quality, and lesion conspicuity as graded on a 5-point scale) were compared among the groups. RESULTS: Group A2 scanned with the automatically chosen 80 kVp and 100 kVp tube voltages ranked the best in lesion conspicuity and subjective and objective image quality (p values ranging from < 0.001 to 0.004) among the three groups, except for overall image quality between group A2 and group B (p = 0.022). Group A1 showed higher image noise (p = 0.005) but similar lesion conspicuity and overall image quality as compared with group B. The radiation dose in group A was 19% lower than that in group B (p = 0.022). CONCLUSION: CT scanning with combined use of ATVS and ATCM and image reconstruction with SAFIRE algorithm provides higher lesion conspicuity and better image quality for evaluating small hepatic HCCs with radiation dose reduction.
format Online
Article
Text
id pubmed-4435983
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-44359832015-05-20 Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality Lv, Peijie Liu, Jie Zhang, Rui Jia, Yan Gao, Jianbo Korean J Radiol Gastrointestinal Imaging OBJECTIVE: To assess the lesion conspicuity and image quality in CT evaluation of small (≤ 3 cm) hepatocellular carcinomas (HCCs) using automatic tube voltage selection (ATVS) and automatic tube current modulation (ATCM) with or without iterative reconstruction. MATERIALS AND METHODS: One hundred and five patients with 123 HCC lesions were included. Fifty-seven patients were scanned using both ATVS and ATCM and images were reconstructed using either filtered back-projection (FBP) (group A1) or sinogram-affirmed iterative reconstruction (SAFIRE) (group A2). Forty-eight patients were imaged using only ATCM, with a fixed tube potential of 120 kVp and FBP reconstruction (group B). Quantitative parameters (image noise in Hounsfield unit and contrast-to-noise ratio of the aorta, the liver, and the hepatic tumors) and qualitative visual parameters (image noise, overall image quality, and lesion conspicuity as graded on a 5-point scale) were compared among the groups. RESULTS: Group A2 scanned with the automatically chosen 80 kVp and 100 kVp tube voltages ranked the best in lesion conspicuity and subjective and objective image quality (p values ranging from < 0.001 to 0.004) among the three groups, except for overall image quality between group A2 and group B (p = 0.022). Group A1 showed higher image noise (p = 0.005) but similar lesion conspicuity and overall image quality as compared with group B. The radiation dose in group A was 19% lower than that in group B (p = 0.022). CONCLUSION: CT scanning with combined use of ATVS and ATCM and image reconstruction with SAFIRE algorithm provides higher lesion conspicuity and better image quality for evaluating small hepatic HCCs with radiation dose reduction. The Korean Society of Radiology 2015 2015-05-13 /pmc/articles/PMC4435983/ /pubmed/25995682 http://dx.doi.org/10.3348/kjr.2015.16.3.531 Text en Copyright © 2015 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Gastrointestinal Imaging
Lv, Peijie
Liu, Jie
Zhang, Rui
Jia, Yan
Gao, Jianbo
Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality
title Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality
title_full Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality
title_fullStr Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality
title_full_unstemmed Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality
title_short Combined Use of Automatic Tube Voltage Selection and Current Modulation with Iterative Reconstruction for CT Evaluation of Small Hypervascular Hepatocellular Carcinomas: Effect on Lesion Conspicuity and Image Quality
title_sort combined use of automatic tube voltage selection and current modulation with iterative reconstruction for ct evaluation of small hypervascular hepatocellular carcinomas: effect on lesion conspicuity and image quality
topic Gastrointestinal Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435983/
https://www.ncbi.nlm.nih.gov/pubmed/25995682
http://dx.doi.org/10.3348/kjr.2015.16.3.531
work_keys_str_mv AT lvpeijie combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality
AT liujie combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality
AT zhangrui combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality
AT jiayan combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality
AT gaojianbo combineduseofautomatictubevoltageselectionandcurrentmodulationwithiterativereconstructionforctevaluationofsmallhypervascularhepatocellularcarcinomaseffectonlesionconspicuityandimagequality