Cargando…
Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid Nodules
OBJECTIVE: Thyroid nodule measurement using ultrasonography (US) is widely performed in various clinical scenarios. The purpose of this study was to evaluate inter-observer variation in US measurement of the volume and maximum diameter of thyroid nodules. MATERIALS AND METHODS: This retrospective st...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435986/ https://www.ncbi.nlm.nih.gov/pubmed/25995685 http://dx.doi.org/10.3348/kjr.2015.16.3.560 |
_version_ | 1782371984046292992 |
---|---|
author | Choi, Young Jun Baek, Jung Hwan Hong, Min Ji Lee, Jeong Hyun |
author_facet | Choi, Young Jun Baek, Jung Hwan Hong, Min Ji Lee, Jeong Hyun |
author_sort | Choi, Young Jun |
collection | PubMed |
description | OBJECTIVE: Thyroid nodule measurement using ultrasonography (US) is widely performed in various clinical scenarios. The purpose of this study was to evaluate inter-observer variation in US measurement of the volume and maximum diameter of thyroid nodules. MATERIALS AND METHODS: This retrospective study included 73 consecutive patients with 85 well-defined thyroid nodules greater than 1 cm in their maximum diameter. US examinations were independently performed by using standardized measurement methods, conducted by two clinically experienced thyroid radiologists. The maximum nodule diameter and nodule volume, calculated from nodule diameters using the ellipsoid formula, were obtained by each reader. Inter-observer variations in volume and maximum diameter were determined using 95% Bland-Altman limits of agreement. The degree of inter-observer variations in volumes and the maximum diameters were compared using the Student's t test, between nodules < 2 cm in maximum diameter and those with ≥ 2 cm. RESULTS: The mean inter-observer difference in measuring the nodule volume was -1.6%, in terms of percentage of the nodule volume, and the 95% limit of agreement was ± 13.1%. For maximum nodule diameter, the mean inter-observer difference was -0.6%, in terms of percentage of the nodule diameter, and the 95% limit of agreement was ± 7.3%. Inter-observer variation in volume was greater in nodules of < 2 cm in maximum diameter, compared to the larger nodules (p = 0.035). However, no statistically significant difference was noted between the two groups regarding maximum nodule diameters (p = 0.511). CONCLUSION: Any differences smaller than 13.1% and 7.3% in volume and maximum diameter, respectively, measured by using US for well-defined thyroid nodules of > 1 cm should not be considered as a real change in size. |
format | Online Article Text |
id | pubmed-4435986 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-44359862015-05-20 Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid Nodules Choi, Young Jun Baek, Jung Hwan Hong, Min Ji Lee, Jeong Hyun Korean J Radiol Neuroimaging and Head & Neck OBJECTIVE: Thyroid nodule measurement using ultrasonography (US) is widely performed in various clinical scenarios. The purpose of this study was to evaluate inter-observer variation in US measurement of the volume and maximum diameter of thyroid nodules. MATERIALS AND METHODS: This retrospective study included 73 consecutive patients with 85 well-defined thyroid nodules greater than 1 cm in their maximum diameter. US examinations were independently performed by using standardized measurement methods, conducted by two clinically experienced thyroid radiologists. The maximum nodule diameter and nodule volume, calculated from nodule diameters using the ellipsoid formula, were obtained by each reader. Inter-observer variations in volume and maximum diameter were determined using 95% Bland-Altman limits of agreement. The degree of inter-observer variations in volumes and the maximum diameters were compared using the Student's t test, between nodules < 2 cm in maximum diameter and those with ≥ 2 cm. RESULTS: The mean inter-observer difference in measuring the nodule volume was -1.6%, in terms of percentage of the nodule volume, and the 95% limit of agreement was ± 13.1%. For maximum nodule diameter, the mean inter-observer difference was -0.6%, in terms of percentage of the nodule diameter, and the 95% limit of agreement was ± 7.3%. Inter-observer variation in volume was greater in nodules of < 2 cm in maximum diameter, compared to the larger nodules (p = 0.035). However, no statistically significant difference was noted between the two groups regarding maximum nodule diameters (p = 0.511). CONCLUSION: Any differences smaller than 13.1% and 7.3% in volume and maximum diameter, respectively, measured by using US for well-defined thyroid nodules of > 1 cm should not be considered as a real change in size. The Korean Society of Radiology 2015 2015-05-13 /pmc/articles/PMC4435986/ /pubmed/25995685 http://dx.doi.org/10.3348/kjr.2015.16.3.560 Text en Copyright © 2015 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Neuroimaging and Head & Neck Choi, Young Jun Baek, Jung Hwan Hong, Min Ji Lee, Jeong Hyun Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid Nodules |
title | Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid Nodules |
title_full | Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid Nodules |
title_fullStr | Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid Nodules |
title_full_unstemmed | Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid Nodules |
title_short | Inter-Observer Variation in Ultrasound Measurement of the Volume and Diameter of Thyroid Nodules |
title_sort | inter-observer variation in ultrasound measurement of the volume and diameter of thyroid nodules |
topic | Neuroimaging and Head & Neck |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435986/ https://www.ncbi.nlm.nih.gov/pubmed/25995685 http://dx.doi.org/10.3348/kjr.2015.16.3.560 |
work_keys_str_mv | AT choiyoungjun interobservervariationinultrasoundmeasurementofthevolumeanddiameterofthyroidnodules AT baekjunghwan interobservervariationinultrasoundmeasurementofthevolumeanddiameterofthyroidnodules AT hongminji interobservervariationinultrasoundmeasurementofthevolumeanddiameterofthyroidnodules AT leejeonghyun interobservervariationinultrasoundmeasurementofthevolumeanddiameterofthyroidnodules |