Cargando…
Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study
OBJECTIVE: To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. MATERIALS AND METHODS: A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435995/ https://www.ncbi.nlm.nih.gov/pubmed/25995695 http://dx.doi.org/10.3348/kjr.2015.16.3.641 |
_version_ | 1782371986102550528 |
---|---|
author | Hwang, Sung Ho Oh, Yu-Whan Ham, Soo-Youn Kang, Eun-Young Lee, Ki Yeol |
author_facet | Hwang, Sung Ho Oh, Yu-Whan Ham, Soo-Youn Kang, Eun-Young Lee, Ki Yeol |
author_sort | Hwang, Sung Ho |
collection | PubMed |
description | OBJECTIVE: To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. MATERIALS AND METHODS: A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM using DSCT. The relative percentage volume errors (RPEs) of 3D volumetry were compared between the HPM and CPM. In addition, the intermode volume variability (IVV) of 3D volumetry was calculated. RESULTS: In the measurement of the 6-mm and 8-mm nodules, there was no significant difference in RPE (p > 0.05, respectively) between the CPM and HPM (IVVs of 1.2 ± 0.9%, and 1.7 ± 1.5%, respectively). In the measurement of the 4-mm nodules, the mean RPE in the HPM (35.1 ± 7.4%) was significantly greater (p < 0.01) than that in the CPM (18.4 ± 5.3%), with an IVV of 13.1 ± 6.6%. However, the IVVs were in an acceptable range (< 25%), regardless of nodule size. CONCLUSION: The accuracy of 3D volumetry with HPM for solid pulmonary nodule is comparable to that with CPM. However, the use of HPM may adversely affect the accuracy of 3D volumetry for smaller (< 5 mm in diameter) nodule. |
format | Online Article Text |
id | pubmed-4435995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-44359952015-05-20 Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study Hwang, Sung Ho Oh, Yu-Whan Ham, Soo-Youn Kang, Eun-Young Lee, Ki Yeol Korean J Radiol Thoracic Imaging OBJECTIVE: To evaluate the influence of high-pitch mode (HPM) in dual-source computed tomography (DSCT) on the accuracy of three-dimensional (3D) volumetry for solid pulmonary nodules. MATERIALS AND METHODS: A lung phantom implanted with 45 solid pulmonary nodules (n = 15 for each of 4-mm, 6-mm, and 8-mm in diameter) was scanned twice, first in conventional pitch mode (CPM) and then in HPM using DSCT. The relative percentage volume errors (RPEs) of 3D volumetry were compared between the HPM and CPM. In addition, the intermode volume variability (IVV) of 3D volumetry was calculated. RESULTS: In the measurement of the 6-mm and 8-mm nodules, there was no significant difference in RPE (p > 0.05, respectively) between the CPM and HPM (IVVs of 1.2 ± 0.9%, and 1.7 ± 1.5%, respectively). In the measurement of the 4-mm nodules, the mean RPE in the HPM (35.1 ± 7.4%) was significantly greater (p < 0.01) than that in the CPM (18.4 ± 5.3%), with an IVV of 13.1 ± 6.6%. However, the IVVs were in an acceptable range (< 25%), regardless of nodule size. CONCLUSION: The accuracy of 3D volumetry with HPM for solid pulmonary nodule is comparable to that with CPM. However, the use of HPM may adversely affect the accuracy of 3D volumetry for smaller (< 5 mm in diameter) nodule. The Korean Society of Radiology 2015 2015-05-13 /pmc/articles/PMC4435995/ /pubmed/25995695 http://dx.doi.org/10.3348/kjr.2015.16.3.641 Text en Copyright © 2015 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Thoracic Imaging Hwang, Sung Ho Oh, Yu-Whan Ham, Soo-Youn Kang, Eun-Young Lee, Ki Yeol Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study |
title | Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study |
title_full | Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study |
title_fullStr | Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study |
title_full_unstemmed | Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study |
title_short | Effect of the High-Pitch Mode in Dual-Source Computed Tomography on the Accuracy of Three-Dimensional Volumetry of Solid Pulmonary Nodules: A Phantom Study |
title_sort | effect of the high-pitch mode in dual-source computed tomography on the accuracy of three-dimensional volumetry of solid pulmonary nodules: a phantom study |
topic | Thoracic Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4435995/ https://www.ncbi.nlm.nih.gov/pubmed/25995695 http://dx.doi.org/10.3348/kjr.2015.16.3.641 |
work_keys_str_mv | AT hwangsungho effectofthehighpitchmodeindualsourcecomputedtomographyontheaccuracyofthreedimensionalvolumetryofsolidpulmonarynodulesaphantomstudy AT ohyuwhan effectofthehighpitchmodeindualsourcecomputedtomographyontheaccuracyofthreedimensionalvolumetryofsolidpulmonarynodulesaphantomstudy AT hamsooyoun effectofthehighpitchmodeindualsourcecomputedtomographyontheaccuracyofthreedimensionalvolumetryofsolidpulmonarynodulesaphantomstudy AT kangeunyoung effectofthehighpitchmodeindualsourcecomputedtomographyontheaccuracyofthreedimensionalvolumetryofsolidpulmonarynodulesaphantomstudy AT leekiyeol effectofthehighpitchmodeindualsourcecomputedtomographyontheaccuracyofthreedimensionalvolumetryofsolidpulmonarynodulesaphantomstudy |