Cargando…
Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis?
BACKGROUND: Lupus nephritis (LN) is a common and severe manifestation of systemic lupus erythematosus (SLE) that can lead to end-stage renal disease. According to the Kidney Disease Outcomes Global Improving clinical Guidelines for Glomerulonephritis, spot urine protein/creatinine (P/C) ratio should...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4438366/ https://www.ncbi.nlm.nih.gov/pubmed/26069827 http://dx.doi.org/10.1093/ckj/sft118 |
_version_ | 1782372318993973248 |
---|---|
author | Guedes Marques, Maria Cotovio, Patrícia Ferrer, Francisco Silva, Cristina Botelho, Carlos Lopes, Karina Maia, Pedro Carreira, Armando Campos, Mário |
author_facet | Guedes Marques, Maria Cotovio, Patrícia Ferrer, Francisco Silva, Cristina Botelho, Carlos Lopes, Karina Maia, Pedro Carreira, Armando Campos, Mário |
author_sort | Guedes Marques, Maria |
collection | PubMed |
description | BACKGROUND: Lupus nephritis (LN) is a common and severe manifestation of systemic lupus erythematosus (SLE) that can lead to end-stage renal disease. According to the Kidney Disease Outcomes Global Improving clinical Guidelines for Glomerulonephritis, spot urine protein/creatinine (P/C) ratio should be used for monitoring LN. However, some reports write that the random spot urine P/C ratio is unreliable in monitoring proteinuria in SLE glomerulonephritis patients. The aim of this study was to evaluate the agreement of these two assay methods. METHODS: The prospective observational study was performed. Fifty-three paired (total 106) spot and 24-h urine collections were evaluated. Statistical analysis: SPSS 20.0. RESULTS: Paired samples t-test did not reveal significant differences between the two-paired assay methods (spot P/C ratio versus 24-h proteinuria and 24-h P/C ratio) and a statistically significant correlation was observed between them: Pearson's coefficient of 0.847 (P < 0.001) and 0.863 (P < 0.001), respectively. However, after stratifying by degrees of proteinuria, a poor correlation was found in the range of <500 mg/day and only 26.6% of 24-h P/C ratio was explained by the spot P/C ratio. Adding to this, for proteinuria range between 500 and 1000 mg/day, there was no correlation (Pearson's −0.098; P > 0.05). In fact, only 1% of 24-h measurements could be explained by the spot P/C ratio. CONCLUSIONS: Our study demonstrated a good correlation between 24-h proteinuria and random P/C ratio among patients with LN. However, this correlation was poor for proteinuria under 500 mg/day and did not exist in a range between 500 and 1000 mg/day. This finding is of greater importance because this range is quite common in patients with LN remission. Until further clarification, to the best of our knowledge, we maintain reluctant to completely substitute the 24-h collection by the P/C ratio especially when a renal flare is suspected, or before any change in therapy. |
format | Online Article Text |
id | pubmed-4438366 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-44383662015-06-11 Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis? Guedes Marques, Maria Cotovio, Patrícia Ferrer, Francisco Silva, Cristina Botelho, Carlos Lopes, Karina Maia, Pedro Carreira, Armando Campos, Mário Clin Kidney J Original Contributions BACKGROUND: Lupus nephritis (LN) is a common and severe manifestation of systemic lupus erythematosus (SLE) that can lead to end-stage renal disease. According to the Kidney Disease Outcomes Global Improving clinical Guidelines for Glomerulonephritis, spot urine protein/creatinine (P/C) ratio should be used for monitoring LN. However, some reports write that the random spot urine P/C ratio is unreliable in monitoring proteinuria in SLE glomerulonephritis patients. The aim of this study was to evaluate the agreement of these two assay methods. METHODS: The prospective observational study was performed. Fifty-three paired (total 106) spot and 24-h urine collections were evaluated. Statistical analysis: SPSS 20.0. RESULTS: Paired samples t-test did not reveal significant differences between the two-paired assay methods (spot P/C ratio versus 24-h proteinuria and 24-h P/C ratio) and a statistically significant correlation was observed between them: Pearson's coefficient of 0.847 (P < 0.001) and 0.863 (P < 0.001), respectively. However, after stratifying by degrees of proteinuria, a poor correlation was found in the range of <500 mg/day and only 26.6% of 24-h P/C ratio was explained by the spot P/C ratio. Adding to this, for proteinuria range between 500 and 1000 mg/day, there was no correlation (Pearson's −0.098; P > 0.05). In fact, only 1% of 24-h measurements could be explained by the spot P/C ratio. CONCLUSIONS: Our study demonstrated a good correlation between 24-h proteinuria and random P/C ratio among patients with LN. However, this correlation was poor for proteinuria under 500 mg/day and did not exist in a range between 500 and 1000 mg/day. This finding is of greater importance because this range is quite common in patients with LN remission. Until further clarification, to the best of our knowledge, we maintain reluctant to completely substitute the 24-h collection by the P/C ratio especially when a renal flare is suspected, or before any change in therapy. Oxford University Press 2013-12 2013-09-30 /pmc/articles/PMC4438366/ /pubmed/26069827 http://dx.doi.org/10.1093/ckj/sft118 Text en © The Author 2013. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved. For permissions, please email: journals.permissions@oup.com. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Original Contributions Guedes Marques, Maria Cotovio, Patrícia Ferrer, Francisco Silva, Cristina Botelho, Carlos Lopes, Karina Maia, Pedro Carreira, Armando Campos, Mário Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis? |
title | Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis? |
title_full | Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis? |
title_fullStr | Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis? |
title_full_unstemmed | Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis? |
title_short | Random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis? |
title_sort | random spot urine protein/creatinine ratio: a reliable method for monitoring lupus nephritis? |
topic | Original Contributions |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4438366/ https://www.ncbi.nlm.nih.gov/pubmed/26069827 http://dx.doi.org/10.1093/ckj/sft118 |
work_keys_str_mv | AT guedesmarquesmaria randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis AT cotoviopatricia randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis AT ferrerfrancisco randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis AT silvacristina randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis AT botelhocarlos randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis AT lopeskarina randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis AT maiapedro randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis AT carreiraarmando randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis AT camposmario randomspoturineproteincreatinineratioareliablemethodformonitoringlupusnephritis |