Cargando…
High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor
An improved thermal-needle approach for accurate and fast measurement of thermal conductivity of aqueous and soft biomaterials was developed using microfabricated thermal conductivity sensors. This microscopic measuring device was comprehensively characterized at temperatures from 0 °C to 40 °C. Des...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4438607/ https://www.ncbi.nlm.nih.gov/pubmed/25993037 http://dx.doi.org/10.1038/srep10377 |
_version_ | 1782372365181648896 |
---|---|
author | Liang, Xin M. Sekar, Praveen K. Zhao, Gang Zhou, Xiaoming Shu, Zhiquan Huang, Zhongping Ding, Weiping Zhang, Qingchuan Gao, Dayong |
author_facet | Liang, Xin M. Sekar, Praveen K. Zhao, Gang Zhou, Xiaoming Shu, Zhiquan Huang, Zhongping Ding, Weiping Zhang, Qingchuan Gao, Dayong |
author_sort | Liang, Xin M. |
collection | PubMed |
description | An improved thermal-needle approach for accurate and fast measurement of thermal conductivity of aqueous and soft biomaterials was developed using microfabricated thermal conductivity sensors. This microscopic measuring device was comprehensively characterized at temperatures from 0 °C to 40 °C. Despite the previous belief, system calibration constant was observed to be highly temperature-dependent. Dynamic thermal conductivity response during cooling (40 °C to –40 °C) was observed using the miniaturized single tip sensor for various concentrations of CPAs, i.e., glycerol, ethylene glycol and dimethyl sulfoxide. Chicken breast, chicken skin, porcine limb, and bovine liver were assayed to investigate the effect of anatomical heterogeneity on thermal conductivity using the arrayed multi-tip sensor at 20 °C. Experimental results revealed distinctive differences in localized thermal conductivity, which suggests the use of approximated or constant property values is expected to bring about results with largely inflated uncertainties when investigating bio-heat transfer mechanisms and/or performing sophisticated thermal modeling with complex biological tissues. Overall, the presented micro thermal sensor with automated data analysis algorithm is a promising approach for direct thermal conductivity measurement of aqueous solutions and soft biomaterials and is of great value to cryopreservation of tissues, hyperthermia or cryogenic, and other thermal-based clinical diagnostics and treatments. |
format | Online Article Text |
id | pubmed-4438607 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-44386072015-06-01 High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor Liang, Xin M. Sekar, Praveen K. Zhao, Gang Zhou, Xiaoming Shu, Zhiquan Huang, Zhongping Ding, Weiping Zhang, Qingchuan Gao, Dayong Sci Rep Article An improved thermal-needle approach for accurate and fast measurement of thermal conductivity of aqueous and soft biomaterials was developed using microfabricated thermal conductivity sensors. This microscopic measuring device was comprehensively characterized at temperatures from 0 °C to 40 °C. Despite the previous belief, system calibration constant was observed to be highly temperature-dependent. Dynamic thermal conductivity response during cooling (40 °C to –40 °C) was observed using the miniaturized single tip sensor for various concentrations of CPAs, i.e., glycerol, ethylene glycol and dimethyl sulfoxide. Chicken breast, chicken skin, porcine limb, and bovine liver were assayed to investigate the effect of anatomical heterogeneity on thermal conductivity using the arrayed multi-tip sensor at 20 °C. Experimental results revealed distinctive differences in localized thermal conductivity, which suggests the use of approximated or constant property values is expected to bring about results with largely inflated uncertainties when investigating bio-heat transfer mechanisms and/or performing sophisticated thermal modeling with complex biological tissues. Overall, the presented micro thermal sensor with automated data analysis algorithm is a promising approach for direct thermal conductivity measurement of aqueous solutions and soft biomaterials and is of great value to cryopreservation of tissues, hyperthermia or cryogenic, and other thermal-based clinical diagnostics and treatments. Nature Publishing Group 2015-05-20 /pmc/articles/PMC4438607/ /pubmed/25993037 http://dx.doi.org/10.1038/srep10377 Text en Copyright © 2015, Macmillan Publishers Limited http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ |
spellingShingle | Article Liang, Xin M. Sekar, Praveen K. Zhao, Gang Zhou, Xiaoming Shu, Zhiquan Huang, Zhongping Ding, Weiping Zhang, Qingchuan Gao, Dayong High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor |
title | High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor |
title_full | High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor |
title_fullStr | High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor |
title_full_unstemmed | High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor |
title_short | High accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor |
title_sort | high accuracy thermal conductivity measurement of aqueous cryoprotective agents and semi-rigid biological tissues using a microfabricated thermal sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4438607/ https://www.ncbi.nlm.nih.gov/pubmed/25993037 http://dx.doi.org/10.1038/srep10377 |
work_keys_str_mv | AT liangxinm highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor AT sekarpraveenk highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor AT zhaogang highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor AT zhouxiaoming highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor AT shuzhiquan highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor AT huangzhongping highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor AT dingweiping highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor AT zhangqingchuan highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor AT gaodayong highaccuracythermalconductivitymeasurementofaqueouscryoprotectiveagentsandsemirigidbiologicaltissuesusingamicrofabricatedthermalsensor |