Cargando…
Minimally Invasive Electro-Magnetic Navigational Bronchoscopy-Integrated Near-Infrared-Guided Sentinel Lymph Node Mapping in the Porcine Lung
BACKGROUND: The use of near-infrared (NIR) fluorescence imaging with indocyanine green (ICG) for sentinel lymph node (SN) mapping has been investigated in lung cancer; however, this has not been fully adapted for minimally invasive surgery (MIS). The aim of our study was to develop a minimally invas...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4438870/ https://www.ncbi.nlm.nih.gov/pubmed/25993006 http://dx.doi.org/10.1371/journal.pone.0126945 |
_version_ | 1782372406368665600 |
---|---|
author | Wada, Hironobu Hirohashi, Kentaro Anayama, Takashi Nakajima, Takahiro Kato, Tatsuya Chan, Harley H. L. Qiu, Jimmy Daly, Michael Weersink, Robert Jaffray, David A. Irish, Jonathan C. Waddell, Thomas K. Keshavjee, Shaf Yoshino, Ichiro Yasufuku, Kazuhiro |
author_facet | Wada, Hironobu Hirohashi, Kentaro Anayama, Takashi Nakajima, Takahiro Kato, Tatsuya Chan, Harley H. L. Qiu, Jimmy Daly, Michael Weersink, Robert Jaffray, David A. Irish, Jonathan C. Waddell, Thomas K. Keshavjee, Shaf Yoshino, Ichiro Yasufuku, Kazuhiro |
author_sort | Wada, Hironobu |
collection | PubMed |
description | BACKGROUND: The use of near-infrared (NIR) fluorescence imaging with indocyanine green (ICG) for sentinel lymph node (SN) mapping has been investigated in lung cancer; however, this has not been fully adapted for minimally invasive surgery (MIS). The aim of our study was to develop a minimally invasive SN mapping integrating pre-operative electro-magnetic navigational bronchoscopy (ENB)-guided transbronchial ICG injection and intraoperative NIR thoracoscopic imaging. METHODS: A NIR thoracoscope was used to visualize ICG fluorescence. ICG solutions in a 96-well plate and ex vivo porcine lungs were examined to optimize ICG concentrations and injection volumes. Transbronchial ICG injection (n=4) was assessed in comparison to a traditional transpleural approach (n=3), where after thoracotomy an ICG solution (100μL at 100μg/mL) was injected into the porcine right upper lobe for SN identification. For further translation into clinical use, transbronchial ICG injection prior to thoracotomy followed by NIR thoracoscopic imaging was validated (n=3). ENB was used for accurate targeting in two pigs with a pseudo-tumor. RESULTS: The ICG fluorescence at 10 μg/mL was the brightest among various concentrations, unchanged by the distance between the thoracoscope and ICG solutions. Injected ICG of no more than 500μL showed a localized fluorescence area. All 7 pigs showed a bright paratracheal lymph node within 15 minutes post-injection, with persistent fluorescence for 60 minutes. The antecedent transbronchial ICG injection succeeded in SN identification in all 3 cases at the first thoracoscopic inspection within 20 minutes post-injection. The ENB system allowed accurate ICG injection surrounding the pseudo-tumors. CONCLUSIONS: ENB-guided ICG injection followed by NIR thoracoscopy was technically feasible for SN mapping in the porcine lung. This promising platform may be translated into human clinical trials and is suited for MIS. |
format | Online Article Text |
id | pubmed-4438870 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-44388702015-05-29 Minimally Invasive Electro-Magnetic Navigational Bronchoscopy-Integrated Near-Infrared-Guided Sentinel Lymph Node Mapping in the Porcine Lung Wada, Hironobu Hirohashi, Kentaro Anayama, Takashi Nakajima, Takahiro Kato, Tatsuya Chan, Harley H. L. Qiu, Jimmy Daly, Michael Weersink, Robert Jaffray, David A. Irish, Jonathan C. Waddell, Thomas K. Keshavjee, Shaf Yoshino, Ichiro Yasufuku, Kazuhiro PLoS One Research Article BACKGROUND: The use of near-infrared (NIR) fluorescence imaging with indocyanine green (ICG) for sentinel lymph node (SN) mapping has been investigated in lung cancer; however, this has not been fully adapted for minimally invasive surgery (MIS). The aim of our study was to develop a minimally invasive SN mapping integrating pre-operative electro-magnetic navigational bronchoscopy (ENB)-guided transbronchial ICG injection and intraoperative NIR thoracoscopic imaging. METHODS: A NIR thoracoscope was used to visualize ICG fluorescence. ICG solutions in a 96-well plate and ex vivo porcine lungs were examined to optimize ICG concentrations and injection volumes. Transbronchial ICG injection (n=4) was assessed in comparison to a traditional transpleural approach (n=3), where after thoracotomy an ICG solution (100μL at 100μg/mL) was injected into the porcine right upper lobe for SN identification. For further translation into clinical use, transbronchial ICG injection prior to thoracotomy followed by NIR thoracoscopic imaging was validated (n=3). ENB was used for accurate targeting in two pigs with a pseudo-tumor. RESULTS: The ICG fluorescence at 10 μg/mL was the brightest among various concentrations, unchanged by the distance between the thoracoscope and ICG solutions. Injected ICG of no more than 500μL showed a localized fluorescence area. All 7 pigs showed a bright paratracheal lymph node within 15 minutes post-injection, with persistent fluorescence for 60 minutes. The antecedent transbronchial ICG injection succeeded in SN identification in all 3 cases at the first thoracoscopic inspection within 20 minutes post-injection. The ENB system allowed accurate ICG injection surrounding the pseudo-tumors. CONCLUSIONS: ENB-guided ICG injection followed by NIR thoracoscopy was technically feasible for SN mapping in the porcine lung. This promising platform may be translated into human clinical trials and is suited for MIS. Public Library of Science 2015-05-20 /pmc/articles/PMC4438870/ /pubmed/25993006 http://dx.doi.org/10.1371/journal.pone.0126945 Text en © 2015 Wada et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Wada, Hironobu Hirohashi, Kentaro Anayama, Takashi Nakajima, Takahiro Kato, Tatsuya Chan, Harley H. L. Qiu, Jimmy Daly, Michael Weersink, Robert Jaffray, David A. Irish, Jonathan C. Waddell, Thomas K. Keshavjee, Shaf Yoshino, Ichiro Yasufuku, Kazuhiro Minimally Invasive Electro-Magnetic Navigational Bronchoscopy-Integrated Near-Infrared-Guided Sentinel Lymph Node Mapping in the Porcine Lung |
title | Minimally Invasive Electro-Magnetic Navigational Bronchoscopy-Integrated Near-Infrared-Guided Sentinel Lymph Node Mapping in the Porcine Lung |
title_full | Minimally Invasive Electro-Magnetic Navigational Bronchoscopy-Integrated Near-Infrared-Guided Sentinel Lymph Node Mapping in the Porcine Lung |
title_fullStr | Minimally Invasive Electro-Magnetic Navigational Bronchoscopy-Integrated Near-Infrared-Guided Sentinel Lymph Node Mapping in the Porcine Lung |
title_full_unstemmed | Minimally Invasive Electro-Magnetic Navigational Bronchoscopy-Integrated Near-Infrared-Guided Sentinel Lymph Node Mapping in the Porcine Lung |
title_short | Minimally Invasive Electro-Magnetic Navigational Bronchoscopy-Integrated Near-Infrared-Guided Sentinel Lymph Node Mapping in the Porcine Lung |
title_sort | minimally invasive electro-magnetic navigational bronchoscopy-integrated near-infrared-guided sentinel lymph node mapping in the porcine lung |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4438870/ https://www.ncbi.nlm.nih.gov/pubmed/25993006 http://dx.doi.org/10.1371/journal.pone.0126945 |
work_keys_str_mv | AT wadahironobu minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT hirohashikentaro minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT anayamatakashi minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT nakajimatakahiro minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT katotatsuya minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT chanharleyhl minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT qiujimmy minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT dalymichael minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT weersinkrobert minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT jaffraydavida minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT irishjonathanc minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT waddellthomask minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT keshavjeeshaf minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT yoshinoichiro minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung AT yasufukukazuhiro minimallyinvasiveelectromagneticnavigationalbronchoscopyintegratednearinfraredguidedsentinellymphnodemappingintheporcinelung |