Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication

BACKGROUND: Although endoscopic third ventriculostomy is a safe procedure, the authors report a case of aneurysmal subarachnoid hemorrhage as an unusual and serious complication of an endoscopic third ventriculostomy and ventricular drainage. CASE DESCRIPTION: A 60-year-old male presented with obstr...

Descripción completa

Detalles Bibliográficos
Autores principales: Miyagi, Naohisa, Uchikado, Hisaaki, Aoki, Takachika, Sakata, Kiyohiko, Hirohata, Masaru, Morioka, Motohiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4439787/
https://www.ncbi.nlm.nih.gov/pubmed/26009704
http://dx.doi.org/10.4103/2152-7806.157303
_version_ 1782372555736219648
author Miyagi, Naohisa
Uchikado, Hisaaki
Aoki, Takachika
Sakata, Kiyohiko
Hirohata, Masaru
Morioka, Motohiro
author_facet Miyagi, Naohisa
Uchikado, Hisaaki
Aoki, Takachika
Sakata, Kiyohiko
Hirohata, Masaru
Morioka, Motohiro
author_sort Miyagi, Naohisa
collection PubMed
description BACKGROUND: Although endoscopic third ventriculostomy is a safe procedure, the authors report a case of aneurysmal subarachnoid hemorrhage as an unusual and serious complication of an endoscopic third ventriculostomy and ventricular drainage. CASE DESCRIPTION: A 60-year-old male presented with obstructive hydrocephalus caused by midbrain tumors was admitted to our hospital. Endoscopic third ventriculostomy and external ventricular drainage were successfully performed. Two days after the operation, he became comatose, and a computed tomography (CT) scan revealed a diffuse subarachnoid hemorrhage. Emergency cerebral angiogram showed an aneurysm of the left internal carotid artery. Endovascular coil embolization of the ruptured aneurysm was then performed. CONCLUSION: The rupture of the aneurysm may have been induced by excessive cerebrospinal fluid drainage after the endoscopic third ventriculostomy. Planning for intracranial endoscopic procedures should consider that rupture of an unknown previously unruptured aneurysm is a possible complication.
format Online
Article
Text
id pubmed-4439787
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-44397872015-05-25 Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication Miyagi, Naohisa Uchikado, Hisaaki Aoki, Takachika Sakata, Kiyohiko Hirohata, Masaru Morioka, Motohiro Surg Neurol Int Case Report BACKGROUND: Although endoscopic third ventriculostomy is a safe procedure, the authors report a case of aneurysmal subarachnoid hemorrhage as an unusual and serious complication of an endoscopic third ventriculostomy and ventricular drainage. CASE DESCRIPTION: A 60-year-old male presented with obstructive hydrocephalus caused by midbrain tumors was admitted to our hospital. Endoscopic third ventriculostomy and external ventricular drainage were successfully performed. Two days after the operation, he became comatose, and a computed tomography (CT) scan revealed a diffuse subarachnoid hemorrhage. Emergency cerebral angiogram showed an aneurysm of the left internal carotid artery. Endovascular coil embolization of the ruptured aneurysm was then performed. CONCLUSION: The rupture of the aneurysm may have been induced by excessive cerebrospinal fluid drainage after the endoscopic third ventriculostomy. Planning for intracranial endoscopic procedures should consider that rupture of an unknown previously unruptured aneurysm is a possible complication. Medknow Publications & Media Pvt Ltd 2015-05-19 /pmc/articles/PMC4439787/ /pubmed/26009704 http://dx.doi.org/10.4103/2152-7806.157303 Text en Copyright: © 2015 Miyagi N. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Case Report
Miyagi, Naohisa
Uchikado, Hisaaki
Aoki, Takachika
Sakata, Kiyohiko
Hirohata, Masaru
Morioka, Motohiro
Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication
title Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication
title_full Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication
title_fullStr Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication
title_full_unstemmed Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication
title_short Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication
title_sort nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: case report of a rare complication
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4439787/
https://www.ncbi.nlm.nih.gov/pubmed/26009704
http://dx.doi.org/10.4103/2152-7806.157303
work_keys_str_mv AT miyaginaohisa nontraumaticaneurysmrupturefollowinganendoscopicthirdventriculostomyandventriculardrainagecasereportofararecomplication
AT uchikadohisaaki nontraumaticaneurysmrupturefollowinganendoscopicthirdventriculostomyandventriculardrainagecasereportofararecomplication
AT aokitakachika nontraumaticaneurysmrupturefollowinganendoscopicthirdventriculostomyandventriculardrainagecasereportofararecomplication
AT sakatakiyohiko nontraumaticaneurysmrupturefollowinganendoscopicthirdventriculostomyandventriculardrainagecasereportofararecomplication
AT hirohatamasaru nontraumaticaneurysmrupturefollowinganendoscopicthirdventriculostomyandventriculardrainagecasereportofararecomplication
AT moriokamotohiro nontraumaticaneurysmrupturefollowinganendoscopicthirdventriculostomyandventriculardrainagecasereportofararecomplication