Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study

BACKGROUND: The purpose of this study was to determine errors in measurement of torsional profiles (TP) (torsional femoral angle, torsional tibial angle, and femoral ankle angle) among four orthopedic surgeons, experts, and non-experts in measurement, and the learning curve. METHODS: Twenty-six lowe...

Descripción completa

Detalles Bibliográficos
Autores principales: Panou, Artemisia, Stanitski, Dedorah Faith, Stanitski, Carl, Peccati, Andrea, Portinaro, Nicola Marcello
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4440600/
https://www.ncbi.nlm.nih.gov/pubmed/25971620
http://dx.doi.org/10.1186/s13018-015-0200-1
_version_ 1782372664471453696
author Panou, Artemisia
Stanitski, Dedorah Faith
Stanitski, Carl
Peccati, Andrea
Portinaro, Nicola Marcello
author_facet Panou, Artemisia
Stanitski, Dedorah Faith
Stanitski, Carl
Peccati, Andrea
Portinaro, Nicola Marcello
author_sort Panou, Artemisia
collection PubMed
description BACKGROUND: The purpose of this study was to determine errors in measurement of torsional profiles (TP) (torsional femoral angle, torsional tibial angle, and femoral ankle angle) among four orthopedic surgeons, experts, and non-experts in measurement, and the learning curve. METHODS: Twenty-six lower extremities of 13 patients with spastic diplegia candidates for femoral/tibial derotational osteotomy had preoperative bilateral computer tomography (CT) scan grams to establish the TP. Each measurement was done by four orthopedic surgeons, two experienced clinicians and interpreters of CT imaging and two with limited clinical and imaging assessment experiences. Images were blinded and the surgeons made three determinations at least 5 days apart; the three angles were measured each time for each limb. Intra-observer and inter-observer variability were determined using bias, standard deviation, and interclass correlation coefficient. RESULTS: Significant inter-observer variability and bias were noted between experts and non-experts (average variability: ICC experts: 0.88 ± 0.15; ICC non-experts: 0.91 ± 0.09). For non-experts, excessive bias (25° and 14°) was observed. An associated improvement in bias with additional measurement experience indicated a potential significant learning curve for interpreting these studies. Less inter-observer variability was observed between experts. CONCLUSIONS: Measurement of TP is a reliable tool when used by experienced personnel, and their use as a preoperative tool should be reserved to ones with experience with such image assessments. Non-experts’ measurements produced a weak agreement when compared to experts’.
format Online
Article
Text
id pubmed-4440600
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-44406002015-05-22 Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study Panou, Artemisia Stanitski, Dedorah Faith Stanitski, Carl Peccati, Andrea Portinaro, Nicola Marcello J Orthop Surg Res Research Article BACKGROUND: The purpose of this study was to determine errors in measurement of torsional profiles (TP) (torsional femoral angle, torsional tibial angle, and femoral ankle angle) among four orthopedic surgeons, experts, and non-experts in measurement, and the learning curve. METHODS: Twenty-six lower extremities of 13 patients with spastic diplegia candidates for femoral/tibial derotational osteotomy had preoperative bilateral computer tomography (CT) scan grams to establish the TP. Each measurement was done by four orthopedic surgeons, two experienced clinicians and interpreters of CT imaging and two with limited clinical and imaging assessment experiences. Images were blinded and the surgeons made three determinations at least 5 days apart; the three angles were measured each time for each limb. Intra-observer and inter-observer variability were determined using bias, standard deviation, and interclass correlation coefficient. RESULTS: Significant inter-observer variability and bias were noted between experts and non-experts (average variability: ICC experts: 0.88 ± 0.15; ICC non-experts: 0.91 ± 0.09). For non-experts, excessive bias (25° and 14°) was observed. An associated improvement in bias with additional measurement experience indicated a potential significant learning curve for interpreting these studies. Less inter-observer variability was observed between experts. CONCLUSIONS: Measurement of TP is a reliable tool when used by experienced personnel, and their use as a preoperative tool should be reserved to ones with experience with such image assessments. Non-experts’ measurements produced a weak agreement when compared to experts’. BioMed Central 2015-05-15 /pmc/articles/PMC4440600/ /pubmed/25971620 http://dx.doi.org/10.1186/s13018-015-0200-1 Text en © Panou et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Panou, Artemisia
Stanitski, Dedorah Faith
Stanitski, Carl
Peccati, Andrea
Portinaro, Nicola Marcello
Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study
title Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study
title_full Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study
title_fullStr Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study
title_full_unstemmed Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study
title_short Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study
title_sort intra-observer and inter-observer errors in ct measurement of torsional profiles of lower limbs: a retrospective comparative study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4440600/
https://www.ncbi.nlm.nih.gov/pubmed/25971620
http://dx.doi.org/10.1186/s13018-015-0200-1
work_keys_str_mv AT panouartemisia intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy
AT stanitskidedorahfaith intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy
AT stanitskicarl intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy
AT peccatiandrea intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy
AT portinaronicolamarcello intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy