Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study
BACKGROUND: The purpose of this study was to determine errors in measurement of torsional profiles (TP) (torsional femoral angle, torsional tibial angle, and femoral ankle angle) among four orthopedic surgeons, experts, and non-experts in measurement, and the learning curve. METHODS: Twenty-six lowe...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4440600/ https://www.ncbi.nlm.nih.gov/pubmed/25971620 http://dx.doi.org/10.1186/s13018-015-0200-1 |
_version_ | 1782372664471453696 |
---|---|
author | Panou, Artemisia Stanitski, Dedorah Faith Stanitski, Carl Peccati, Andrea Portinaro, Nicola Marcello |
author_facet | Panou, Artemisia Stanitski, Dedorah Faith Stanitski, Carl Peccati, Andrea Portinaro, Nicola Marcello |
author_sort | Panou, Artemisia |
collection | PubMed |
description | BACKGROUND: The purpose of this study was to determine errors in measurement of torsional profiles (TP) (torsional femoral angle, torsional tibial angle, and femoral ankle angle) among four orthopedic surgeons, experts, and non-experts in measurement, and the learning curve. METHODS: Twenty-six lower extremities of 13 patients with spastic diplegia candidates for femoral/tibial derotational osteotomy had preoperative bilateral computer tomography (CT) scan grams to establish the TP. Each measurement was done by four orthopedic surgeons, two experienced clinicians and interpreters of CT imaging and two with limited clinical and imaging assessment experiences. Images were blinded and the surgeons made three determinations at least 5 days apart; the three angles were measured each time for each limb. Intra-observer and inter-observer variability were determined using bias, standard deviation, and interclass correlation coefficient. RESULTS: Significant inter-observer variability and bias were noted between experts and non-experts (average variability: ICC experts: 0.88 ± 0.15; ICC non-experts: 0.91 ± 0.09). For non-experts, excessive bias (25° and 14°) was observed. An associated improvement in bias with additional measurement experience indicated a potential significant learning curve for interpreting these studies. Less inter-observer variability was observed between experts. CONCLUSIONS: Measurement of TP is a reliable tool when used by experienced personnel, and their use as a preoperative tool should be reserved to ones with experience with such image assessments. Non-experts’ measurements produced a weak agreement when compared to experts’. |
format | Online Article Text |
id | pubmed-4440600 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-44406002015-05-22 Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study Panou, Artemisia Stanitski, Dedorah Faith Stanitski, Carl Peccati, Andrea Portinaro, Nicola Marcello J Orthop Surg Res Research Article BACKGROUND: The purpose of this study was to determine errors in measurement of torsional profiles (TP) (torsional femoral angle, torsional tibial angle, and femoral ankle angle) among four orthopedic surgeons, experts, and non-experts in measurement, and the learning curve. METHODS: Twenty-six lower extremities of 13 patients with spastic diplegia candidates for femoral/tibial derotational osteotomy had preoperative bilateral computer tomography (CT) scan grams to establish the TP. Each measurement was done by four orthopedic surgeons, two experienced clinicians and interpreters of CT imaging and two with limited clinical and imaging assessment experiences. Images were blinded and the surgeons made three determinations at least 5 days apart; the three angles were measured each time for each limb. Intra-observer and inter-observer variability were determined using bias, standard deviation, and interclass correlation coefficient. RESULTS: Significant inter-observer variability and bias were noted between experts and non-experts (average variability: ICC experts: 0.88 ± 0.15; ICC non-experts: 0.91 ± 0.09). For non-experts, excessive bias (25° and 14°) was observed. An associated improvement in bias with additional measurement experience indicated a potential significant learning curve for interpreting these studies. Less inter-observer variability was observed between experts. CONCLUSIONS: Measurement of TP is a reliable tool when used by experienced personnel, and their use as a preoperative tool should be reserved to ones with experience with such image assessments. Non-experts’ measurements produced a weak agreement when compared to experts’. BioMed Central 2015-05-15 /pmc/articles/PMC4440600/ /pubmed/25971620 http://dx.doi.org/10.1186/s13018-015-0200-1 Text en © Panou et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Panou, Artemisia Stanitski, Dedorah Faith Stanitski, Carl Peccati, Andrea Portinaro, Nicola Marcello Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study |
title | Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study |
title_full | Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study |
title_fullStr | Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study |
title_full_unstemmed | Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study |
title_short | Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study |
title_sort | intra-observer and inter-observer errors in ct measurement of torsional profiles of lower limbs: a retrospective comparative study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4440600/ https://www.ncbi.nlm.nih.gov/pubmed/25971620 http://dx.doi.org/10.1186/s13018-015-0200-1 |
work_keys_str_mv | AT panouartemisia intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy AT stanitskidedorahfaith intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy AT stanitskicarl intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy AT peccatiandrea intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy AT portinaronicolamarcello intraobserverandinterobservererrorsinctmeasurementoftorsionalprofilesoflowerlimbsaretrospectivecomparativestudy |