Cargando…
Single locking compression plate fixation of extra-articular distal humeral fractures
BACKGROUND: Earlier literature on fixation of distal third humeral fractures describes the use of elaborate modification of existing implants, custom-made implants and dual plating. These modifications have the disadvantages of limitations of hardware availability and cost as well as longer surgical...
Autores principales: | Kumar, Malhar N., Ravishankar, M. R., Manur, Ravikiran |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4441632/ https://www.ncbi.nlm.nih.gov/pubmed/25326853 http://dx.doi.org/10.1007/s10195-014-0325-8 |
Ejemplares similares
-
Outcome of locking compression plates in humeral shaft nonunions
por: Kumar, Malhar N, et al.
Publicado: (2013) -
Functional outcomes of extra-articular scapula fracture fixation with distal humeral Y-type locking plate: a retrospective study
por: Hu, Yuanjun, et al.
Publicado: (2019) -
A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
por: Jayakumar, Prakash, et al.
Publicado: (2015) -
Anatomic fit of precontoured extra-articular distal humeral locking plates: a cadaveric study
por: Lim, Joon-Ryul, et al.
Publicado: (2021) -
Distal medial tibial locking plate for fixation of extraarticular distal humeral fractures; an alternative choice for fixation
por: Yorukoglu, Ali Cagdas, et al.
Publicado: (2018)