Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples

BACKGROUND: Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. OBJECTIVES: To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH resu...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohammadhoseini, Elham, Safavi, Enayat, Seifi, Sepideh, Seifirad, Soroush, Firoozbakhsh, Shahram, Peiman, Soheil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4441774/
https://www.ncbi.nlm.nih.gov/pubmed/26019892
http://dx.doi.org/10.5812/ircmj.13577
_version_ 1782372820386316288
author Mohammadhoseini, Elham
Safavi, Enayat
Seifi, Sepideh
Seifirad, Soroush
Firoozbakhsh, Shahram
Peiman, Soheil
author_facet Mohammadhoseini, Elham
Safavi, Enayat
Seifi, Sepideh
Seifirad, Soroush
Firoozbakhsh, Shahram
Peiman, Soheil
author_sort Mohammadhoseini, Elham
collection PubMed
description BACKGROUND: Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. OBJECTIVES: To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. PATIENTS AND METHODS: 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. RESULTS: PaO(2) of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO(2) of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P < 0.001). In samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. CONCLUSIONS: In samples stored in plastic syringes, overestimation of PaO(2) levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour.
format Online
Article
Text
id pubmed-4441774
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Kowsar
record_format MEDLINE/PubMed
spelling pubmed-44417742015-05-27 Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples Mohammadhoseini, Elham Safavi, Enayat Seifi, Sepideh Seifirad, Soroush Firoozbakhsh, Shahram Peiman, Soheil Iran Red Crescent Med J Research Article BACKGROUND: Results of arterial blood gas analysis can be biased by pre-analytical factors, such as time interval before analysis, temperature during storage and syringe type. OBJECTIVES: To investigate the effects of samples storage temperature and time delay on blood gases, bicarbonate and PH results in human arterial blood samples. PATIENTS AND METHODS: 2.5 mL arterial blood samples were drawn from 45 patients via an indwelling Intraarterial catheter. Each sample was divided into five equal samples and stored in multipurpose tuberculin plastic syringes. Blood gas analysis was performed on one of five samples as soon as possible. Four other samples were divided into two groups stored at 22°C and 0°C. Blood gas analyses were repeated at 30 and 60 minutes after sampling. RESULTS: PaO(2) of the samples stored at 0°C was increased significantly after 60 minutes (P = 0.007). The PaCO(2) of the samples kept for 30 and 60 minutes at 22°C was significantly higher than primary result (P = 0.04, P < 0.001). In samples stored at 22°C, pH decreased significantly after 30 and 60 minutes (P = 0.017, P = 0.001). There were no significant differences in other results of samples stored at 0°C or 22°C after 30 or 60 minutes. CONCLUSIONS: In samples stored in plastic syringes, overestimation of PaO(2) levels should be noted if samples cooled before analysis. In samples stored in plastic syringes, it is not necessary to store samples in iced water when analysis delayed up to one hour. Kowsar 2015-03-20 /pmc/articles/PMC4441774/ /pubmed/26019892 http://dx.doi.org/10.5812/ircmj.13577 Text en Copyright © 2015, Iranian Red Crescent Medical Journal. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited.
spellingShingle Research Article
Mohammadhoseini, Elham
Safavi, Enayat
Seifi, Sepideh
Seifirad, Soroush
Firoozbakhsh, Shahram
Peiman, Soheil
Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples
title Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples
title_full Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples
title_fullStr Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples
title_full_unstemmed Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples
title_short Effect of Sample Storage Temperature and Time Delay on Blood Gases, Bicarbonate and pH in Human Arterial Blood Samples
title_sort effect of sample storage temperature and time delay on blood gases, bicarbonate and ph in human arterial blood samples
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4441774/
https://www.ncbi.nlm.nih.gov/pubmed/26019892
http://dx.doi.org/10.5812/ircmj.13577
work_keys_str_mv AT mohammadhoseinielham effectofsamplestoragetemperatureandtimedelayonbloodgasesbicarbonateandphinhumanarterialbloodsamples
AT safavienayat effectofsamplestoragetemperatureandtimedelayonbloodgasesbicarbonateandphinhumanarterialbloodsamples
AT seifisepideh effectofsamplestoragetemperatureandtimedelayonbloodgasesbicarbonateandphinhumanarterialbloodsamples
AT seifiradsoroush effectofsamplestoragetemperatureandtimedelayonbloodgasesbicarbonateandphinhumanarterialbloodsamples
AT firoozbakhshshahram effectofsamplestoragetemperatureandtimedelayonbloodgasesbicarbonateandphinhumanarterialbloodsamples
AT peimansoheil effectofsamplestoragetemperatureandtimedelayonbloodgasesbicarbonateandphinhumanarterialbloodsamples